CoChat

Electrochemical treatment of textile wastewater

· 1996 · Water Science and Technology
Cited by 148

The DOI matches its Crossref record.

Abstract

The treatment of textile wastewater, containing a high concentration of Cl- ion, by an electrochemical method using Ti/RuO2, Ti/Pt and Ti/Pt/Ir electrodes is investigated. All three anodes proved to be very effective in direct or indirect oxidation of organics present in the wastewater. After 60 min of electrolysis at 6 A/dm2, COD was reduced by 85-92% and DOC by about 85%. Of the three electrodes tested, the efficiency of organics removal followed the order: Ti/RuO2 > Ti/Pt > Ti/Pt/Ir. The electrochemical treatment of textile wastewater resulted in the production of many chloroorganics in high concentration. GC-MS analysis showed the presence of the following major products: 1,1-dichlorocyclopentene, 2,3-dichloro-2-methylbutane, chloromethylsilane, 2,3-dichloro-2-methyl butanoic acid, 2,3-dichloro-2-methyl propanol, 2,3-dimethyl-2, 3-butanediol and 2-butylphenol.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0273-1223(96)00816-5

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 148

Metadata

Venue
Water Science and Technology
Published
1996
Volume
34
Issue
11
ISSN
0273-1223 (ISSN-L)
OpenAlex
W2001775945
Cited by
148
References
0
FWCI
0.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrochemical treatment of textile wastewater. https://app.cochat.ai/papers/10.1016/s0273-1223(96)00816-5
The paper
Electrochemical treatment of textile wastewater. (1996). Water Science and Technology. https://doi.org/10.1016/s0273-1223(96)00816-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.