Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 250

The DOI matches its Crossref record.

Clinical precision of myofascial trigger point location in the trapezius muscle

Sciotti, Veronica M., Mittak, Veronica L., DiMarco, Lisa, Ford, Lillian M., Plezbert, Julie, Santipadri, Eileen, Wigglesworth, Janet, Ball, Kevin·2001·Pain

Abstract

Myofascial trigger points (TrPs) have been clinically described as discrete areas of muscle tenderness presenting in taut bands of skeletal muscle. Using well-defined clinical criteria, prior investigations have demonstrated interrater reliability in the diagnosis of TrPs within a given muscle. No reports exist, however, with respect to the precision with which experienced clinicians can determine the anatomic locations of TrPs within a muscle. This paper details a study wherein four trained clinicians achieved statistically significant reliability (see below) in estimating the precise locations of latent TrPs in the trapezius muscle of volunteer subjects (n=20). To do so, the clinicians trained extensively together prior to the study. The precise anatomic location of each subject's primary TrP was measured in a blinded fashion using a 3 dimensional (3-D) camera system. Use of this measurement system permitted the anatomic co-ordinates of each TrP to be located without providing feedback to subsequent clinicians. The clinicians each used a pressure algometer along with patient feedback to document the sensitivity of each suspected TrP site, however unlike routine clinical practice, the algometry was performed with a double-blinded approach hence the results were only examined post-hoc. At the time of data collection (algometry readings unknown), 16 of the 20 subjects were judged to present with a latent TrP. Subsequently, when subjected to a criterion pressure threshold value of <3.0 kg.cm(-2), 12 of these TrPs were classified as being clinically sensitive. To assess the 3-D measurement precision, and the reliability of the TrP estimates, statistical measures of the SEM and the Generalizability coefficient (G-coeff) were determined for all suspected TrP sites in the superior-inferior, medial-lateral and anterior-posterior directions. The best results were determined by pooling the measurements of all 4 clinicians, however, based upon exceeding a criterion reliability threshold of 80%, the use of just two testers was found to produce reliable results. The two-tester condition yielded a precision of 7.5, 7.6 and 6.5 mm (SEM) with reliability (G-coeff) of 0.92, 0.86 and 0.83, respectively. Given the double-blinded methodology, the use of pressure algometry was also found to demonstrate internal validity. The algometer responses associated with TrP estimates varied inversely with respect to the clinical group's reliability in identify the TrP locations. To summarize, for the trapezius muscle, this study demonstrates that two trained examiners can reliably localize latent TrPs with a precision that essentially approaches the physical dimensions of the clinician's own fingertips. Finally, it should be recognized that the ability to precisely document TrP location appears critical to the success of future studies that may be designed to investigate the etiology and pathogenesis of this commonly diagnosed clinical disorder.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0304-3959(01)00325-6

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 250

Metadata

Authors
Sciotti, V. M., Mittak, V. L., DiMarco, L., Ford, L. M., Plezbert, J., Santipadri, E., Wigglesworth, J., & Ball, K.
Venue
Pain
Published
2001-09
Volume
93
Issue
3
Pages
259-266
ISSN
0304-3959 (ISSN-L)
OpenAlex
W2089829904
Cited by
250
References
0
FWCI
1.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical precision of myofascial trigger point location in the trapezius muscle. https://app.cochat.ai/papers/10.1016/s0304-3959(01)00325-6
The paper
Sciotti, V. M., Mittak, V. L., DiMarco, L., Ford, L. M., Plezbert, J., Santipadri, E., Wigglesworth, J., & Ball, K. (2001). Clinical precision of myofascial trigger point location in the trapezius muscle. Pain. https://doi.org/10.1016/s0304-3959(01)00325-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.