Cooling-energy reduction in air-conditioned offices by using night ventilation
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Asimakopoulos, D. (2013) · Routledge eBooks · doi:10.4324/9781315073668 · Cited by 310
Givoni, B. (1998) · Energy and Buildings · doi:10.1016/s0378-7788(97)00056-x · Cited by 166
Night ventilation for building cooling in summer
Blondeau, P., Spérandio, M., & Allard, F. (1997) · Solar Energy · doi:10.1016/s0038-092x(97)00076-5 · Cited by 160
Natural ventilation for passive cooling: measurement of discharge coefficients
Flourentzou, F., der Maas, J. V., & Roulet, C.-A. (1998) · Energy and Buildings · doi:10.1016/s0378-7788(97)00043-1 · Cited by 128
Third-order lumped-parameter simulation method
Tindale, A. (1993) · Building Services Engineering Research and Technology · doi:10.1177/014362449301400302 · Cited by 69
On the efficiency of night ventilation techniques for thermostatically controlled buildings
Santamouris, M., Mihalakakou, G. K., Argiriou, A. A., & Asimakopoulos, D. N. (1996) · Solar Energy · doi:10.1016/0038-092x(95)00119-c · Cited by 26
Cited by
Passive cooling dissipation techniques for buildings and other structures: The state of the art
Santamouris, M., & Kolokotsa, D. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2012.11.002 · Cited by 446
Zhou, N., Khanna, N., Feng, W., Ke, J., & Levine, M. (2018) · Nature Energy · doi:10.1038/s41560-018-0253-6 · Cited by 410
Mirrahimi, S., Mohamed, M. F., Haw, L. C., Ibrahim, N. L. N., Yusoff, W. F. M., & Aflaki, A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.09.055 · Cited by 407
Kolokotroni, M., Giannitsaris, I., & Watkins, R. (2006) · Solar Energy · doi:10.1016/j.solener.2005.03.010 · Cited by 345
Self-citationControlled natural ventilation for energy efficient buildings
Schulze, T., & Eicker, U. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2012.07.044 · Cited by 268
Investigating natural ventilation potentials across the globe: Regional and climatic variations
Chen, Y., Tong, Z., & Malkawi, A. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.06.026 · Cited by 225
Kolaitis, D. I., Malliotakis, E., Kontogeorgos, D. A., Mandilaras, I., Katsourinis, D. I., & Founti, M. A. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.04.004 · Cited by 223
Tong, Z., Chen, Y., Malkawi, A., Adamkiewicz, G., & Spengler, J. D. (2016) · Environment International · doi:10.1016/j.envint.2016.01.016 · Cited by 222
“Previous studies have shown that the cooling energy consumption of studied buildings can be reduced by 40–50% using natural ventilation in European cities (Cardinale et al., 2003; Gratia and De Herde, 2004; Kolokotroni and Aronis, 1999).”
BackgroundKubota, T., Chyee, D. T. H., & Ahmad, S. (2009) · Energy and Buildings · doi:10.1016/j.enbuild.2009.03.008 · Cited by 206
RetractedPassive alternatives to mechanical air conditioning of building: A review
Samuel, D. G. L., Nagendra, S. M. S., & Maiya, M. P. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.04.016 · Cited by 184
Heracleous, C., & Michael, A. (2019) · Journal of Building Engineering · doi:10.1016/j.jobe.2019.100917 · Cited by 159
Passive cooling & climate responsive façade design
Prieto, A., Knaack, U., Auer, T., & Klein, T. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.06.016 · Cited by 91
Optimization of cool roof and night ventilation in office buildings: A case study in Xiamen, China
Guo, R., Gao, Y., Zhuang, C., Heiselberg, P., Levinson, R., Zhao, X., & Shi, D. (2020) · Renewable Energy · doi:10.1016/j.renene.2019.10.032 · Cited by 58
“P4 Internal thermal mass level m 2 U a [10-80]”
Metadata
- Authors
- Kolokotroni, M., & Aronis, A.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 1999-08
- Volume
- 63
- Issue
- 4
- Pages
- 241-253
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2023477350
- Cited by
- 188
- References
- 6
- FWCI
- 7.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.