Cited by 226Advanced MRI Techniques and ApplicationsLiver Disease Diagnosis and TreatmentNMR spectroscopy and applications

Introduction of fast MR imaging in the assessment of hepatic steatosis

Fishbein, Mark H., Gardner, Kathryn G., Potter, Carol J., Schmalbrock, Petra, Smith, Mark A.·1997·Magnetic Resonance Imaging

Abstract

We determined the utility of fast gradient echo techniques (modified Dixon method) in the assessment of hepatic fat content. Fast spoiled gradient echo was performed on bovine liver/corn oil homogenates with known fat fractions (FFE) to assess the accuracy of fat quantitation (FFMRI). The pulse sequence was manipulated via alterations in TE (echo time), TR (repetition time), and alpha (flip angle). In vivo studies were then performed using breath-holding maneuvers on normal adult volunteers and subjects at risk to develop hepatic steatosis, with cystic fibrosis or morbid obesity. At out-of-phase, TE, TR, and alpha were 2.1 ms, 7.3 ms, and 30-50 degrees and in-phase TE, TR, and alpha were 4.2 ms, 9.3 ms, and 30-50 degrees; FFMRI correlated well with FFE. An elevated fat fraction was observed in a high percentage of subjects with cystic fibrosis and morbid obesity. Fast gradient echo techniques were used successfully in the assessment of hepatic steatosis. The reduced acquisition times permitted in vivo analysis on adults and children using breath hold maneuvers.

Integrity signals

Registry

Crossref · 10.1016/s0730-725x(96)00224-x

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 12 · Cited by 226

Authors
Fishbein, M. H., Gardner, K. G., Potter, C. J., Schmalbrock, P., & Smith, M. A.
Affiliations
Nationwide Children's Hospital (US)
Corresponding author
Fishbein, Mark H.
Venue
Magnetic Resonance Imaging
Publisher
Elsevier BV
Published
1997-01
Volume
15
Issue
3
Pages
287-293
ISSN
0730-725X (ISSN-L)
OpenAlex
W2041966182
Cited by
226
References
12
Citations by year
2026: 1 · 2024: 5 · 2023: 3 · 2022: 2 · 2021: 3 · 2020: 4 · 2019: 7 · 2018: 4 · 2017: 10 · 2016: 8 · 2015: 11 · 2014: 8 · 2013: 16 · 2012: 9
FWCI
1.60
Type
journal article
Language
en
Open access
closed
Locations
  • Magnetic Resonance Imaging (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Health Sciences › Medicine › Epidemiology › Liver Disease Diagnosis and Treatment
  • Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › NMR spectroscopy and applications
Keywords
hepatic steatosis, fast spoiled gradient echo, cystic fibrosis, morbid obesity, breath-holding, pediatric radiology
MeSH terms
Adipose Tissue, Adult, Animals, Cattle, Child, Corn Oil, Cystic Fibrosis, Fatty Liver, Hepatomegaly, Humans, Image Enhancement, Image Processing, Computer-Assisted, Liver, Magnetic Resonance Imaging, Obesity, Morbid, Respiration, Time Factors, Phantoms, Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review