Introduction of fast MR imaging in the assessment of hepatic steatosis
Abstract
We determined the utility of fast gradient echo techniques (modified Dixon method) in the assessment of hepatic fat content. Fast spoiled gradient echo was performed on bovine liver/corn oil homogenates with known fat fractions (FFE) to assess the accuracy of fat quantitation (FFMRI). The pulse sequence was manipulated via alterations in TE (echo time), TR (repetition time), and alpha (flip angle). In vivo studies were then performed using breath-holding maneuvers on normal adult volunteers and subjects at risk to develop hepatic steatosis, with cystic fibrosis or morbid obesity. At out-of-phase, TE, TR, and alpha were 2.1 ms, 7.3 ms, and 30-50 degrees and in-phase TE, TR, and alpha were 4.2 ms, 9.3 ms, and 30-50 degrees; FFMRI correlated well with FFE. An elevated fat fraction was observed in a high percentage of subjects with cystic fibrosis and morbid obesity. Fast gradient echo techniques were used successfully in the assessment of hepatic steatosis. The reduced acquisition times permitted in vivo analysis on adults and children using breath hold maneuvers.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The modified Dixon method was used to assess the hepatic fat fraction.
“The modified Dixon method was used to assess the hepatic fat fraction.”
From Leptin reverses nonalcoholic steatohepatitis in patients with severe lipodystrophy† (2005) · cites this paper as [13]
The citation lists haven’t been fetched yet
References 12 · Cited by 226
- Authors
- Fishbein, M. H., Gardner, K. G., Potter, C. J., Schmalbrock, P., & Smith, M. A.
- Affiliations
- Nationwide Children's Hospital (US)
- Corresponding author
- Fishbein, Mark H.
- Venue
- Magnetic Resonance Imaging
- Publisher
- Elsevier BV
- Published
- 1997-01
- Volume
- 15
- Issue
- 3
- Pages
- 287-293
- ISSN
- 0730-725X (ISSN-L)
- OpenAlex
- W2041966182
- Cited by
- 226
- References
- 12
- Citations by year
- 2026: 1 · 2024: 5 · 2023: 3 · 2022: 2 · 2021: 3 · 2020: 4 · 2019: 7 · 2018: 4 · 2017: 10 · 2016: 8 · 2015: 11 · 2014: 8 · 2013: 16 · 2012: 9
- FWCI
- 1.60
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Magnetic Resonance Imaging (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Epidemiology › Liver Disease Diagnosis and Treatment
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › NMR spectroscopy and applications
- Keywords
- hepatic steatosis, fast spoiled gradient echo, cystic fibrosis, morbid obesity, breath-holding, pediatric radiology
- MeSH terms
- Adipose Tissue, Adult, Animals, Cattle, Child, Corn Oil, Cystic Fibrosis, Fatty Liver, Hepatomegaly, Humans, Image Enhancement, Image Processing, Computer-Assisted, Liver, Magnetic Resonance Imaging, Obesity, Morbid, Respiration, Time Factors, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review