Measurement of aortic blood flow by doppler echocardiography: Day to day variability in normal subjects and applicability in clinical research
Open accessThe DOI matches its Crossref record.
Abstract
To assess the reliability of Doppler ultrasound for detecting serial changes in cardiac output in response to experimental interventions, the day to day variability of the minute distance of aortic flow was determined in seven normal subjects maintained in a tightly controlled environment with regard to diet and activities. Measurements were made at the same time on 5 to 6 sequential days from an apical window with use of both continuous wave and pulsed wave Doppler techniques. Two statistical measures of reliability were calculated, the intraclass coefficient of correlation (R), which varies between 0 (null reliability) and +1 (perfect reliability), and the 95% confidence interval for the error-free value of a single measurement. For sequential measurements of arterial pressure, 24 h urinary volume and sodium excretion and body weight, the intraclass coefficients of correlation ranged from 0.85 to 0.99, indicating low day to day variability consistent with tight environmental control. Continuous and pulsed wave modes were proved equally and highly reliable for measuring minute distance of aortic flow. However, continuous wave Doppler ultrasound provided acceptable signals more frequently than did the pulsed wave technique. For continuous wave Doppler ultrasound, R was 0.87 (p less than 0.00001); the 95% confidence interval was +/- 1.81 m/min (or 11% of the mean of all measurements), which indicates that this method can be used in a single individual to detect a greater than 11% change in minute distance measured once before and after an intervention.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quiñones, M. A., Otto, C. M., Stoddard, M., Waggoner, A., & Zoghbi, W. A. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2002.120202 · Cited by 2,130
Naughton, M. T., Rahman, M. A., Hara, K., Floras, J. S., & Bradley, T. D. (1995) · Circulation · doi:10.1161/01.cir.91.6.1725 · Cited by 466
Kelly, R., & Fitchett, D. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90198-v · Cited by 361
American society of echocardiography
Ryan, T., & Khandheria, B. K. (2000) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(00)90052-x · Cited by 347
Systemic hypoperfusion is associated with executive dysfunction in geriatric cardiac patients
Jefferson, A. L., Poppas, A., Paul, R. H., & Cohen, R. A. (2007) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2006.01.001 · Cited by 146
“While this method reflects a non-invasive procedure for obtaining CO, previous research has shown that data generated from such noninvasive procedures strongly correlates with invasive measures of CO [18].”
Metadata
- Authors
- Moulinier, L., Venet, T., Schiller, N. B., Kurtz, T. W., Curtis Morris, R., & Sebastian, A.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 1991-05
- Volume
- 17
- Issue
- 6
- Pages
- 1326-1333
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2020782371
- Cited by
- 71
- References
- 0
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of aortic blood flow by doppler echocardiography: Day to day variability in normal subjects and applicability in clinical research. https://app.cochat.ai/papers/10.1016/s0735-1097(10)80143-3
- The paper
- Moulinier, L., Venet, T., Schiller, N. B., Kurtz, T. W., Curtis Morris, R., & Sebastian, A. (1991). Measurement of aortic blood flow by doppler echocardiography: Day to day variability in normal subjects and applicability in clinical research. Journal of the American College of Cardiology. https://doi.org/10.1016/s0735-1097(10)80143-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.