CoChat

Measurement of aortic blood flow by doppler echocardiography: Day to day variability in normal subjects and applicability in clinical research

Open access
Moulinier, Laurence, Venet, Theodore, Schiller, Nelson B., Kurtz, Theodore W., Curtis Morris, R., Sebastian, Anthony · 1991 · Journal of the American College of Cardiology
Cited by 71

The DOI matches its Crossref record.

Abstract

To assess the reliability of Doppler ultrasound for detecting serial changes in cardiac output in response to experimental interventions, the day to day variability of the minute distance of aortic flow was determined in seven normal subjects maintained in a tightly controlled environment with regard to diet and activities. Measurements were made at the same time on 5 to 6 sequential days from an apical window with use of both continuous wave and pulsed wave Doppler techniques. Two statistical measures of reliability were calculated, the intraclass coefficient of correlation (R), which varies between 0 (null reliability) and +1 (perfect reliability), and the 95% confidence interval for the error-free value of a single measurement. For sequential measurements of arterial pressure, 24 h urinary volume and sodium excretion and body weight, the intraclass coefficients of correlation ranged from 0.85 to 0.99, indicating low day to day variability consistent with tight environmental control. Continuous and pulsed wave modes were proved equally and highly reliable for measuring minute distance of aortic flow. However, continuous wave Doppler ultrasound provided acceptable signals more frequently than did the pulsed wave technique. For continuous wave Doppler ultrasound, R was 0.87 (p less than 0.00001); the 95% confidence interval was +/- 1.81 m/min (or 11% of the mean of all measurements), which indicates that this method can be used in a single individual to detect a greater than 11% change in minute distance measured once before and after an intervention.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0735-1097(10)80143-3

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 71

Metadata

Authors
Moulinier, L., Venet, T., Schiller, N. B., Kurtz, T. W., Curtis Morris, R., & Sebastian, A.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
1991-05
Volume
17
Issue
6
Pages
1326-1333
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2020782371
Cited by
71
References
0
FWCI
1.70
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of aortic blood flow by doppler echocardiography: Day to day variability in normal subjects and applicability in clinical research. https://app.cochat.ai/papers/10.1016/s0735-1097(10)80143-3
The paper
Moulinier, L., Venet, T., Schiller, N. B., Kurtz, T. W., Curtis Morris, R., & Sebastian, A. (1991). Measurement of aortic blood flow by doppler echocardiography: Day to day variability in normal subjects and applicability in clinical research. Journal of the American College of Cardiology. https://doi.org/10.1016/s0735-1097(10)80143-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.