Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 227

The DOI matches its Crossref record.

Effect of coronary occlusion during percutaneous transluminal angioplasty in humans on left ventricular chamber stiffness and regional diastolic pressure-radius relations

Open access
Wijns, William, Serruys, Patrick W., Slager, Cornelis J., Grimm, Joerg, Krayenbuehl, Hans P., Hugenholtz, Paul G., Hess, Otto M.·1986·Journal of the American College of Cardiology

Abstract

The effect of repeated (3 to 10 second) and transient (15 to 75 second) abrupt coronary occlusion on the global and regional chamber stiffness was studied in nine patients undergoing angioplasty of a single proximal left anterior descending coronary artery stenosis. The left ventricular high fidelity pressure and volume relation was obtained before and after the procedure as well as during coronary occlusion, after 20 seconds (n = 9) and after 50 seconds (n = 5). During ischemia, there was an upward shift of the pressure-volume relation. The nonlinear simple elastic constant of chamber stiffness increased from 0.0273 +/- 0.017 before angioplasty (mean +/- SD) to 0.0621 +/- 0.026 after 20 seconds of occlusion (p less than 0.05) and 0.0605 +/- 0.015 after 50 seconds of occlusion (p less than 0.01). In five patients, the postangioplasty value remained higher than the control value, but at the group level the mean value (0.0529 +/- 0.037) was not statistically different. The regional stiffness was determined from the changes in the length of six segmental radii during diastole, from the lowest diastolic to the end-diastolic pressure. The regional constant of elastic stiffness was unaffected in the nonischemic zone. In the adjacent and ischemic zones, the regional stiffness was increased during occlusion (p less than 0.05). These regional abnormalities in diastolic function persisted at the time of postangioplasty measurements, 12 minutes after the end of the procedure. This suggests that recovery of normal diastolic function after repeated ischemic injuries is delayed after restoration of normal blood flow and systolic function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0735-1097(86)80453-3

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 227

Metadata

Authors
Wijns, W., Serruys, P. W., Slager, C. J., Grimm, J., Krayenbuehl, H. P., Hugenholtz, P. G., & Hess, O. M.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
1986-03
Volume
7
Issue
3
Pages
455-463
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2122272732
Cited by
227
References
0
FWCI
10.84
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of coronary occlusion during percutaneous transluminal angioplasty in humans on left ventricular chamber stiffness and regional diastolic pressure-radius relations. https://app.cochat.ai/papers/10.1016/s0735-1097(86)80453-3
The paper
Wijns, W., Serruys, P. W., Slager, C. J., Grimm, J., Krayenbuehl, H. P., Hugenholtz, P. G., & Hess, O. M. (1986). Effect of coronary occlusion during percutaneous transluminal angioplasty in humans on left ventricular chamber stiffness and regional diastolic pressure-radius relations. Journal of the American College of Cardiology. https://doi.org/10.1016/s0735-1097(86)80453-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.