Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 390

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Comparison of three Doppler ultrasound methods in the prediction of pulmonary artery pressure

Open access
Chan, Kwan-Leung, Currie, Philip J., Seward, James B., Hagler, Donald J., Mair, Douglas D., Jamil Tajik, A.·1987·Journal of the American College of Cardiology

Abstract

Pulmonary artery pressure was noninvasively estimated by three Doppler echocardiographic methods in 50 consecutive patients undergoing cardiac catheterization. First, a systolic transtricuspid gradient was calculated from Doppler-detected tricuspid regurgitation; clinical jugular venous pressure or a fixed value of 14 mm Hg was added to yield systolic pulmonary artery pressure. Second, acceleration time from pulmonary flow analysis was used in a regression equation to derive mean pulmonary artery pressure. Third, right ventricular isovolumic relaxation time was calculated from Doppler-determined pulmonary valve closure and tricuspid valve opening; systolic pulmonary artery pressure was then derived from a nomogram. In 48 patients (96%) at least one of the methods could be employed. A tricuspid pressure gradient, obtained in 36 patients (72%), provided reliable prediction of systolic pulmonary artery pressure. The prediction was superior when 14 mm Hg rather than estimated jugular venous pressure was used to account for right atrial pressure. In 44 patients (88%), pulmonary flow was analyzed. Prediction of mean pulmonary artery pressure was unsatisfactory (r = 0.65) but improved (r = 0.85) when only patients with a heart rate between 60 and 100 beats/min were considered. The effect of correcting pulmonary flow indexes for heart rate was examined by correlating different flow indexes before and after correction for heart rate. There was a good correlation between corrected acceleration time and either systolic (r = -0.85) or mean (r = -0.83) pulmonary artery pressure. Because of a high incidence of arrhythmia, right ventricular relaxation time could be determined in only 11 patients (22%). Noninvasive prediction of pulmonary artery pressure is feasible in most patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0735-1097(87)80047-5

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 390

Metadata

Authors
Chan, K.-L., Currie, P. J., Seward, J. B., Hagler, D. J., Mair, D. D., & Jamil Tajik, A.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
1987-03
Volume
9
Issue
3
Pages
549-554
ISSN
0735-1097 (ISSN-L)
OpenAlex
W1987707359
Cited by
390
References
11
FWCI
9.24
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of three Doppler ultrasound methods in the prediction of pulmonary artery pressure. https://app.cochat.ai/papers/10.1016/s0735-1097(87)80047-5
The paper
Chan, K.-L., Currie, P. J., Seward, J. B., Hagler, D. J., Mair, D. D., & Jamil Tajik, A. (1987). Comparison of three Doppler ultrasound methods in the prediction of pulmonary artery pressure. Journal of the American College of Cardiology. https://doi.org/10.1016/s0735-1097(87)80047-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.