Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 259

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Clinical Value of Acute Rest Technetium-99m Tetrofosmin Tomographic Myocardial Perfusion Imaging in Patients With Acute Chest Pain and Nondiagnostic Electrocardiograms

Open access
Heller, Gary V, Stowers, Stephen A, Hendel, Robert C, Herman, Steven D, Daher, Edouard, Ahlberg, Alan W, Baron, Jack M, Mendes de Leon, Carlos F, Rizzo, John A, Wackers, Frans J.Th · 1998 · Journal of the American College of Cardiology

Abstract

OBJECTIVES: We sought to evaluate the clinical use and cost-analysis of acute rest technetium-99m (Tc-99m) tetrofosmin single-photon emission computed tomographic (SPECT) myocardial perfusion imaging in patients with chest pain and a normal electrocardiogram (ECG). BACKGROUND: Current approaches used in emergency departments (EDs) for treating patients presenting with chest pain and a nondiagnostic ECG result in poor resource utilization. METHODS: Three hundred fifty-seven patients presenting to six centers with symptoms suggestive of myocardial ischemia and a nondiagnostic ECG underwent Tc-99m tetrofosmin SPECT during or within 6 h of symptoms. Follow-up evaluation was performed during the hospital period and 30 days after discharge. All entry ECGs, SPECT images and cardiac events were reviewed in blinded manner and were not available to the admitting physicians. RESULTS: By consensus interpretation, 204 images (57%) were normal, and 153 were abnormal (43%). Of 20 patients (6%) with an acute myocardial infarction (MI) during the hospital period, 18 had abnormal images (sensitivity 90%), whereas only 2 had normal images (negative predictive value 99%). Multiple logistic regression analysis demonstrated abnormal SPECT imaging to be the best predictor of MI and significantly better than clinical data. Using a normal SPECT image as a criterion not to admit patients would result in a 57% reduction in hospital admissions, with a mean cost savings per patient of $4,258. CONCLUSIONS: Abnormal rest Tc-99m tetrofosmin SPECT imaging accurately predicts acute MI in patients with symptoms and a nondiagnostic ECG, whereas a normal study is associated with a very low cardiac event rate. The use of acute rest SPECT imaging in the ED can substantially and safely reduce the number of unnecessary hospital admissions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0735-1097(98)00057-6

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 259

Metadata

Authors
Heller, G. V., Stowers, S. A., Hendel, R. C., Herman, S. D., Daher, E., Ahlberg, A. W., Baron, J. M., Mendes de Leon, C. F., Rizzo, J. A., & Wackers, F. J. T.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
1998-04
Volume
31
Issue
5
Pages
1011-1017
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2027763481
Cited by
259
References
21
FWCI
13.82
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical Value of Acute Rest Technetium-99m Tetrofosmin Tomographic Myocardial Perfusion Imaging in Patients With Acute Chest Pain and Nondiagnostic Electrocardiograms. https://app.cochat.ai/papers/10.1016/s0735-1097(98)00057-6
The paper
Heller, G. V., Stowers, S. A., Hendel, R. C., Herman, S. D., Daher, E., Ahlberg, A. W., Baron, J. M., Mendes de Leon, C. F., Rizzo, J. A., & Wackers, F. J. T. (1998). Clinical Value of Acute Rest Technetium-99m Tetrofosmin Tomographic Myocardial Perfusion Imaging in Patients With Acute Chest Pain and Nondiagnostic Electrocardiograms. Journal of the American College of Cardiology. https://doi.org/10.1016/s0735-1097(98)00057-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.