CoChat

Programmed ventricular stimulation for arrhythmia risk prediction in patients with idiopathic dilated cardiomyopathy and nonsustained ventricular tachycardia

Open access
Grimm, Wolfram, Hoffmann, Jürgen, Menz, Volker, Luck, Kathrin, Maisch, Bernhard · 1998 · Journal of the American College of Cardiology
Cited by 137

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVES This study investigated the role of programmed ventricular stimulation (PVS) for arrhythmia risk prediction in patients with idiopathic dilated cardiomyopathy (IDC) and spontaneous nonsustained ventricular tachycardia (VT). BACKGROUND Nonsustained VT in patients with IDC has been associated with a high incidence of sudden cardiac death. METHODS Over the course of 4 years, 34 patients with IDC, a left ventricular (LV) ejection fraction < or = 35%, and spontaneous nonsustained VT underwent PVS. All patients were prospectively followed for 24+/-13 months. RESULTS Sustained ventricular arrhythmias were induced in 13 patients (38%). Sustained monomorphic VT was induced in three patients (9%), and polymorphic VT or ventricular fibrillation (VF) in another 10 patients (29%). No sustained ventricular arrhythmia could be induced in 21 study patients (62%). Prophylactic implantation of third-generation defibrillators (ICDs) with electrogram storage capability was performed in all 13 patients with inducible sustained VT or VF, and in nine of 21 patients (43%) without inducible sustained VT or VF. There were no significant differences between the additional use of amiodarone, d,I-sotalol, and beta-blocker therapy during follow-up in patients with and without inducible VT or VF. During 24+/-13 months of follow-up, arrhythmic events were observed in nine patients (26%) including sudden cardiac deaths in two patients and ICD shocks for rapid VT or VF in seven patients. Arrhythmic events during follow-up occurred in four of 13 patients with inducible ventricular arrhythmias compared with five of 21 patients without inducible ventricular arrhythmias at PVS (31% vs. 24%, p=NS). CONCLUSION PVS does not appear to be helpful for arrhythmia risk stratification in patients with IDC, a left ventricular ejection fraction < or =35%, and spontaneous nonsustained VT. Due to the limited number of patients, however, the power of this study is too small to exclude moderately large differences in outcome between patients with IDC with and without inducible VT or VF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0735-1097(98)00306-4

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 137

Metadata

Authors
Grimm, W., Hoffmann, J., Menz, V., Luck, K., & Maisch, B.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
1998-09
Volume
32
Issue
3
Pages
739-745
ISSN
0735-1097 (ISSN-L)
OpenAlex
W1998739518
Cited by
137
References
1
FWCI
6.43
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Programmed ventricular stimulation for arrhythmia risk prediction in patients with idiopathic dilated cardiomyopathy and nonsustained ventricular tachycardia. https://app.cochat.ai/papers/10.1016/s0735-1097(98)00306-4
The paper
Grimm, W., Hoffmann, J., Menz, V., Luck, K., & Maisch, B. (1998). Programmed ventricular stimulation for arrhythmia risk prediction in patients with idiopathic dilated cardiomyopathy and nonsustained ventricular tachycardia. Journal of the American College of Cardiology. https://doi.org/10.1016/s0735-1097(98)00306-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.