CoChat

A quantitative analysis of valgus torque on the ACL: A human cadaveric study

Fukuda, Yukihisa, Woo, Savio L.‐Y., Loh, John C., Tsuda, Eiichi, Tang, Peter, McMahon, Patrick J., Debski, Richard E. · 2003 · Journal of Orthopaedic Research
Cited by 166

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The loads needed to elicit a positive pivot shift test in a knee with an anterior cruciate ligament (ACL) rupture have not been quantified. The coupled anteriol tibial translation (ATT), coupled internal tibial rotation (ITR), and the in situ force in the ACL in response to a valgus torque, an inherent component of the pivot shift test, were measured in 10 human cadaveric knee specimens. Using a robotic/universal force–moment sensor testing system, valgus torques ranging from 0.0 to 10.0 N m were applied in nine increments on the intact and ACL‐deficient knee in flexion ranging from 0° to 90°. At 15° of knee flexion, the coupled ATT and ITR were significantly increased in the ACL‐deficient knee when compared to the intact knee. Coupled ATT increased a maximum of 291% (6.7 mm, p < 0.05), while coupled ITR increased a maximum of 85% (5.1°, p < 0.05). At 30°, the increases in coupled ATT and ITR were significant at valgus loads of 3.3 N m and greater with a maximum increase in coupled ATT of 137% (6.3 mm, p < 0.05) and a maximum increase in coupled ITR of 38% (3.6°, p < 0.05). At 45°, coupled ATT increased significantly (maximum of 69%, 4.4 mm, p < 0.05), but only at torques ⩾ 6.7 N m. The in situ force in the ACL was less than 20 N for all flexion angles when a torque between 3.3 and 5.0 N m was applied. Low valgus torque elicited tibial subluxation in the ACL‐deficient knee with low in situ ACL forces, similar to a positive pivot shift test. Thus, application of a valgus torque may be suitable to evaluate ACL‐deficient and ACL‐reconstructed knees, since subluxation can be achieved with minimal harm to the ACL graft. This work is important in understanding one load component needed for the pivot shift examination; further studies quantifying other load components are essential for better comprehension of the in vivo pivot shift examination. © 2003 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0736-0266(03)00084-6

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 166

Metadata

Authors
Fukuda, Y., Woo, S. L. ‐., Loh, J. C., Tsuda, E., Tang, P., McMahon, P. J., & Debski, R. E.
Venue
Journal of Orthopaedic Research
Publisher
Wiley
Published
2003-11
Volume
21
Issue
6
Pages
1107-1112
ISSN
  • 0736-0266 (ISSN-L)
  • 1554-527X
OpenAlex
W2026618564
Cited by
166
References
1
FWCI
3.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.