Microcirculatory effects of pulsed electromagnetic fields
The DOI matches its Crossref record.
Abstract
Purpose: Pulsed electromagnetic fields (PEMF) are used clinically to expedite healing of fracture non‐unions, however, the mechanism of action by which PEMF stimulation is effective is unknown. The current study examined the acute effects of PEMF stimulation on arteriolar microvessel diameters in the rat cremaster muscle. The study hypothesis was that PEMF would increase arteriolar diameters, a potential mechanism involved in the healing process. Methods: Local PEMF stimulation/sham stimulation of 2 or 60 min duration was delivered to the cremaster muscle of anesthetized rats. Arteriolar diameters were measured before and after stimulation/sham stimulation using intravital microscopy. Systemic hemodynamics also were monitored during PEMF stimulation. Results: Local PEMF stimulation produced significant (p< 0.001) vasodilation, compared to pre‐stimulation values, in cremasteric arterioles in anesthetized rats (n= 24). This dilation occurred after 2 min of stimulation (9% diameter increase) and after 1 h of stimulation (8.7% diameter increase). Rats receiving “sham” stimulation (n= 15) demonstrated no statistically significant change in arteriolar diameter following either “sham” stimulation period. PEMF stimulation of the cremaster (n= 4 rats) did not affect systemic arterial pressure or heart rate, nor was it associated with a change in tissue environmental temperature. Conclusions: These results support the hypothesis that local application of a specific PEMF waveform can elicit significant arteriolar vasodilation. Systemic hemodynamics and environmental temperature could not account for the observed microvascular responses. © 2003 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electromagnetic effects—From cell biology to medicine
Funk, R. H. W., Monsees, T., & Özkucur, N. (2009) · Progress in Histochemistry and Cytochemistry · doi:10.1016/j.proghi.2008.07.001 · Cited by 423
Methods to accelerate fracture healing – a narrative review from a clinical perspective
Ganse, B. (2024) · Frontiers in Immunology · doi:10.3389/fimmu.2024.1384783 · Cited by 33
Effects of Physical Stimulation in the Field of Oral Health
Qi, Y., Zhang, S., Zhang, M., Zhou, Z., Zhang, X., Li, W., Cai, H., Zhao, B. C., Lee, E.-S., & Jiang, H. B. (2021) · Scanning · doi:10.1155/2021/5517567 · Cited by 11
“When the magnet is in the state of attraction, its attraction is controllable and does not decay with time [2].”
BackgroundInfluential
Metadata
- Authors
- Smith, T. L., Wong‐Gibbons, D., & Maultsby, J.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2004-01
- Volume
- 22
- Issue
- 1
- Pages
- 80-84
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W1979987700
- Cited by
- 103
- References
- 0
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microcirculatory effects of pulsed electromagnetic fields. https://app.cochat.ai/papers/10.1016/s0736-0266(03)00157-8
- The paper
- Smith, T. L., Wong‐Gibbons, D., & Maultsby, J. (2004). Microcirculatory effects of pulsed electromagnetic fields. Journal of Orthopaedic Research. https://doi.org/10.1016/s0736-0266(03)00157-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.