Abstract
The function of the anterior and posterior cruciate ligaments (ACL and PCL) in the first 120° of flexion has been reported extensively, but little is known of their behavior at higher flexion angles. The aim of this investigation was to study the effects of muscle loads on the in situ forces in both ligaments at high knee flexion (> 120°). Eighteen fresh‐frozen human knee specimens were tested on a robotic testing system from full extension to 150° of flexion in response to quadriceps (400 N), hamstrings (200 N), and combined quadriceps and hamstrings (400 N/200 N) loads. The in situ forces in the ACL and PCL were measured using the principle of superposition. The force in the ACL peaked at 30° of flexion (71.7 ± 27.9 N in response to the quadriceps load, 52.3 ± 24.4 N in response to the combined muscle load, 32.3 ± 20.9 N in response to the hamstrings load). At 150°, the ACL force was approximately 30 N in response to the quadriceps load and 20 N in response to the combined muscle load and isolated hamstring load. The PCL force peaked at 90° (34.0 ± 15.3 N in response to the quadriceps load, 88.6 ± 23.7 N in response to the combined muscle load, 99.8 ± 24.0 N in response to the hamstrings load) and decreased to around 35 N at 150° in response to each of the loads. These results demonstrate that the ACL and PCL carried significantly less load at high flexion in response to the simulated muscle loads compared to the peak loads they carried in response to the same muscle loads at other flexion angles. The data could provide a reference point for the investigation of non‐weight bearing flexion and extension knee exercises in high flexion. Furthermore, these data could be useful in designing total knee implants to achieve high flexion. © 2003 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanical loads at the knee joint during deep flexion
Nagura, T., Dyrby, C. O., Alexander, E. J., & Andriacchi, T. P. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00178-4 · Cited by 233
Cited by
Squatting Kinematics and Kinetics and Their Application to Exercise Performance
Schoenfeld, B. J. (2010) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181bac2d7 · Cited by 545
Mechanisms of non-contact ACL injuries
Yu, B., & Garrett, W. E. (2007) · British Journal of Sports Medicine · doi:10.1136/bjsm.2007.037192 · Cited by 525
Mechanisms of Noncontact Anterior Cruciate Ligament Injury
Shimokochi, Y., & Shultz, S. J. (2008) · Journal of Athletic Training · doi:10.4085/1062-6050-43.4.396 · Cited by 470
Withrow, T. J., Huston, L. J., Wojtys, E. M., & Ashton-Miller, J. A. (2006) · The American Journal of Sports Medicine · doi:10.1177/0363546505280906 · Cited by 228
“First, in vitro, in knees flexed less than 60°, a simulated increase in quadriceps force increases ACL strain.(17,18) Second, increasing the quadriceps force in vitro up to 4 kN causes anterior tibial translations of greater than 20 mm, and ACL rupture could result.”
BackgroundIn vivo kinematics of the ACL during weight‐bearing knee flexion
Li, G., DeFrate, L. E., Rubash, H. E., & Gill, T. J. (2005) · Journal of Orthopaedic Research · doi:10.1016/j.orthres.2004.08.006 · Cited by 196
“Under simulated muscle loads in in vitro studies [ 20 ,22], the ACL carried higher loads at low flexion angles and minimal loads beyond 60� of flexion.”
MethodSelf-citation
Metadata
- Authors
- Li, G., Zayontz, S., Most, E., DeFrate, L. E., Suggs, J. F., & Rubash, H. E.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2004-03
- Volume
- 22
- Issue
- 2
- Pages
- 293-297
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W1970477135
- Cited by
- 109
- References
- 1
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In situ forces of the anterior and posterior cruciate ligaments in high knee flexion: An in vitro investigation. https://app.cochat.ai/papers/10.1016/s0736-0266(03)00179-7
- The paper
- Li, G., Zayontz, S., Most, E., DeFrate, L. E., Suggs, J. F., & Rubash, H. E. (2004). In situ forces of the anterior and posterior cruciate ligaments in high knee flexion: An in vitro investigation. Journal of Orthopaedic Research. https://doi.org/10.1016/s0736-0266(03)00179-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.