CoChat

In situ forces of the anterior and posterior cruciate ligaments in high knee flexion: An in vitro investigation

Open access
Li, Guoan, Zayontz, Shay, Most, Ephrat, DeFrate, Louis E., Suggs, Jeremy F., Rubash, Harry E. · 2004 · Journal of Orthopaedic Research
Cited by 109

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The function of the anterior and posterior cruciate ligaments (ACL and PCL) in the first 120° of flexion has been reported extensively, but little is known of their behavior at higher flexion angles. The aim of this investigation was to study the effects of muscle loads on the in situ forces in both ligaments at high knee flexion (> 120°). Eighteen fresh‐frozen human knee specimens were tested on a robotic testing system from full extension to 150° of flexion in response to quadriceps (400 N), hamstrings (200 N), and combined quadriceps and hamstrings (400 N/200 N) loads. The in situ forces in the ACL and PCL were measured using the principle of superposition. The force in the ACL peaked at 30° of flexion (71.7 ± 27.9 N in response to the quadriceps load, 52.3 ± 24.4 N in response to the combined muscle load, 32.3 ± 20.9 N in response to the hamstrings load). At 150°, the ACL force was approximately 30 N in response to the quadriceps load and 20 N in response to the combined muscle load and isolated hamstring load. The PCL force peaked at 90° (34.0 ± 15.3 N in response to the quadriceps load, 88.6 ± 23.7 N in response to the combined muscle load, 99.8 ± 24.0 N in response to the hamstrings load) and decreased to around 35 N at 150° in response to each of the loads. These results demonstrate that the ACL and PCL carried significantly less load at high flexion in response to the simulated muscle loads compared to the peak loads they carried in response to the same muscle loads at other flexion angles. The data could provide a reference point for the investigation of non‐weight bearing flexion and extension knee exercises in high flexion. Furthermore, these data could be useful in designing total knee implants to achieve high flexion. © 2003 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0736-0266(03)00179-7

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 109

Metadata

Authors
Li, G., Zayontz, S., Most, E., DeFrate, L. E., Suggs, J. F., & Rubash, H. E.
Venue
Journal of Orthopaedic Research
Publisher
Wiley
Published
2004-03
Volume
22
Issue
2
Pages
293-297
ISSN
  • 0736-0266 (ISSN-L)
  • 1554-527X
OpenAlex
W1970477135
Cited by
109
References
1
FWCI
4.07
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In situ forces of the anterior and posterior cruciate ligaments in high knee flexion: An in vitro investigation. https://app.cochat.ai/papers/10.1016/s0736-0266(03)00179-7
The paper
Li, G., Zayontz, S., Most, E., DeFrate, L. E., Suggs, J. F., & Rubash, H. E. (2004). In situ forces of the anterior and posterior cruciate ligaments in high knee flexion: An in vitro investigation. Journal of Orthopaedic Research. https://doi.org/10.1016/s0736-0266(03)00179-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.