Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 177

The DOI matches its Crossref record.

Ex vivo static tensile loading inhibits MMP‐1 expression in rat tail tendon cells through a cytoskeletally based mechanotransduction mechanism

Arnoczky, Steven P., Tian, Tao, Lavagnino, Michael, Gardner, Keri · 2004 · Journal of Orthopaedic Research

Abstract

To determine the effect of various degrees of ex vivo static tensile loading on the expression of collagenase (MMP‐1) in tendon cells, rat tail tendons were statically loaded in tension at 0.16, 0.77, 1.38 or 2.6 MPa for 24 h. Northern blot analysis was used to assay for mRNA expression of MMP‐1 in freshly harvested, 24 h load deprived, and 24 h statically loaded tendons. Western blot analysis was used to assay for pro‐MMP‐1 and MMP‐1 protein expression in fresh and 24 h load deprived tendons. Freshly harvested rat tail tendons demonstrated no evidence of MMP‐1 mRNA expression and no evidence of the pro‐MMP‐1 or MMP‐1 protein. Ex vivo load deprivation for 24 h resulted in a marked increase in the mRNA expression of MMP‐1 which coincided with a marked increase of both pro‐MMP‐1 and MMP‐1 protein expression. When tendons were subjected to ex vivo static tensile loading during the 24 h culture period, a significant inhibition of this upregulation of MMP‐1 mRNA expression was found with increasing ioad (p < 0.05). A strong (r2 = 0.78) and significant (p < 0.001) inverse correlation existed between the level of static tensile load and the expression of MMP‐1. Disruption of the actin cytoskeleton with cytochalasin D abolished the inhibitory effect of ex vivo static tensile loading on MMP‐1 expression. The results of this study suggest that up‐regulation of MMP‐1 expression in tendon cells ex vivo can be inhibited by static tensile loading, presumably through a cytoskeletally based mechanotransduction pathway. © 2003 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0736-0266(03)00185-2

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 177

Metadata

Authors
Arnoczky, S. P., Tian, T., Lavagnino, M., & Gardner, K.
Venue
Journal of Orthopaedic Research
Publisher
Wiley
Published
2004-03
Volume
22
Issue
2
Pages
328-333
ISSN
  • 0736-0266 (ISSN-L)
  • 1554-527X
OpenAlex
W1996113920
Cited by
177
References
0
FWCI
6.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ex vivo static tensile loading inhibits MMP‐1 expression in rat tail tendon cells through a cytoskeletally based mechanotransduction mechanism. https://app.cochat.ai/papers/10.1016/s0736-0266(03)00185-2
The paper
Arnoczky, S. P., Tian, T., Lavagnino, M., & Gardner, K. (2004). Ex vivo static tensile loading inhibits MMP‐1 expression in rat tail tendon cells through a cytoskeletally based mechanotransduction mechanism. Journal of Orthopaedic Research. https://doi.org/10.1016/s0736-0266(03)00185-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.