The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Biodegradable Implants in Sports Medicine: The Biological Base
Abstract
Biodegradable implants are increasingly used in the field of operative sports medicine. Today, a tremendous variety of implants such as interference screws, staples, sutures, tacks, suture anchors, and devices for meniscal repair are available. These implants consist of different biodegradable polymers that have substantially different raw material characteristics such as in vivo degradation, host-tissue response, and osseous replacement. Because these devices have become the standard implant for several operative procedures, it is essential to understand their biological base. The purpose of this report is to provide a comprehensive insight into biodegradable implant biology for a better understanding of the advantages and risks associated with using these implants in the field of operative sports medicine. In particular, in vivo degradation, biocompatibility, and the osseous replacement of the implants are discussed. A standardized classification system to document and treat possible adverse tissue reactions is given, with special regard to extra-articular and intra-articular soft-tissue response and to osteolytic lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal plasticity: Increasing the gain in pain
Woolf, C. J., & Salter, M. W. (2000) · Science · doi:10.1126/science.288.5472.1765 · Cited by 3,781
Coderre, T. J., Katz, J., Vaccarino, A. L., & Melzack, R. (1993) · Pain · doi:10.1016/0304-3959(93)90161-h · Cited by 1,966
Athanasiou, K. A., Niederauer, G. G., & Agrawal, C. M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85754-1 · Cited by 1,497
Biomaterial biocompatibility and the macrophage
Anderson, J. M., & Miller, K. M. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90060-7 · Cited by 403
BÖSTMAN, O. M. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199205000-00031 · Cited by 185
Acetaminophen Inhibits Spinal Prostaglandin E2Release after Peripheral Noxious Stimulation
Muth-Selbach, U. S., Tegeder, I., Brune, K., & Geisslinger, G. (1999) · Anesthesiology · doi:10.1097/00000542-199907000-00032 · Cited by 142
Cited by
Biodegradable Materials and Metallic Implants—A Review
Prakasam, M., Locs, J., Salma-Ancane, K., Loca, D., Largeteau, A., & Berzina-Cimdina, L. (2017) · Journal of Functional Biomaterials · doi:10.3390/jfb8040044 · Cited by 493
Tendon healing in a bone tunnel. Part II
Weiler, A., Hoffmann, R. F. G., Bail, H. J., Rehm, O., & Südkamp, N. P. (2002) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2002.30657 · Cited by 481
Self-citationJagodzinski, M., Foerstemann, T., Mall, G., Krettek, C., Bosch, U., & Paessler, H. H. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.03.021 · Cited by 79
Metadata
- Authors
- Weiler, A., Hoffmann, R. F. G., Stähelin, A. C., Helling, H.-J., & Südkamp, N. P.
- Venue
- Arthroscopy: The Journal of Arthroscopic & Related Surgery
- Publisher
- Elsevier BV
- Published
- 2000-04
- Volume
- 16
- Issue
- 3
- Pages
- 305-321
- ISSN
- 0749-8063 (ISSN-L)
- OpenAlex
- W2021474499
- Cited by
- 236
- References
- 6
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biodegradable Implants in Sports Medicine: The Biological Base. https://app.cochat.ai/papers/10.1016/s0749-8063(00)90055-0
- The paper
- Weiler, A., Hoffmann, R. F. G., Stähelin, A. C., Helling, H.-J., & Südkamp, N. P. (2000). Biodegradable Implants in Sports Medicine: The Biological Base. Arthroscopy: The Journal of Arthroscopic & Related Surgery. https://doi.org/10.1016/s0749-8063(00)90055-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.