The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Humeral attachment of the supraspinatus and infraspinatus tendons: an anatomic study
Abstract
We investigated the anatomic relationship of the supraspinatus (SSP) and infraspinatus (ISP) tendons to the three facets of the greater tuberosity. After removing the superficial layer of the cuff to expose the tendon fibers in 10 embalmed shoulders, the cuff tendon attachment to the facets was examined, and the location of attachment was measured in reference to (1) the anterior margin of the greater tuberosity and (2) the superior margin of the sulcus (anatomic neck without cartilage). The SSP tendon attached to the superior facet and the superior half of the middle facet. The ISP tendon attached to the entire middle facet, covering a portion of the SSP tendon. Thus, the anterior half of the superior cuff tendon (12.6 +/- 1.1 mm) was composed of only the SSP tendon, whereas the posterior half (9.8 +/- 3.2 mm) was composed of both the SSP and ISP tendons. The sulcus was located not at the SSP-ISP interval but slightly posterior to the posterior margin of the SSP tendon (4.3 +/- 2.4 mm). We conclude that (1) there is an overlap between the SSP and ISP tendons identifiable by the facets or the distance from the anterior greater tuberosity and (2) the sulcus is located slightly posterior to the posterior margin of the SSP tendon.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnosis and Treatment of Incomplete Rotator Cuff Tears
ELLMAN, H. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199005000-00010 · Cited by 678
Cited by
Arthroscopic Repair of Full-Thickness Tears of the Supraspinatus: Does the Tendon Really Heal?
Boileau, P. (2005) · The Journal of Bone and Joint Surgery (American) · doi:10.2106/jbjs.d.02035 · Cited by 1,248
The Insertional Footprint of the Rotator Cuff: An Anatomic Study
Curtis, A. S., Burbank, K. M., Tierney, J. J., Scheller, A. D., & Curran, A. R. (2006) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2006.04.001 · Cited by 316
Cerovecki, T., Bojanic, I., Brcic, L., Radic, B., Vukoja, I., Seiwerth, S., & Sikiric, P. (2010) · Journal of Orthopaedic Research · doi:10.1002/jor.20947 · Cited by 55
Metadata
- Authors
- Minagawa, H., Itoi, E., Konno, N., Kido, T., Sano, A., Urayama, M., & Sato, K.
- Venue
- Arthroscopy: The Journal of Arthroscopic & Related Surgery
- Publisher
- Elsevier BV
- Published
- 1998-04
- Volume
- 14
- Issue
- 3
- Pages
- 302-306
- ISSN
- 0749-8063 (ISSN-L)
- OpenAlex
- W2035384212
- Cited by
- 199
- References
- 1
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Humeral attachment of the supraspinatus and infraspinatus tendons: an anatomic study. https://app.cochat.ai/papers/10.1016/s0749-8063(98)70147-1
- The paper
- Minagawa, H., Itoi, E., Konno, N., Kido, T., Sano, A., Urayama, M., & Sato, K. (1998). Humeral attachment of the supraspinatus and infraspinatus tendons: an anatomic study. Arthroscopy: The Journal of Arthroscopic & Related Surgery. https://doi.org/10.1016/s0749-8063(98)70147-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.