The DOI matches its Crossref record.
Increased higher-order optical aberrations after laser refractive surgery: A problem of subclinical decentration
Abstract
PURPOSE: To study the clinical and theoretical effects of subclinical decentrations on the optical performance of the eye after photorefractive laser surgery. SETTING: Department of Ophthalmology, University of Dresden, Dresden, Germany. METHODS: Ocular aberrations were determined before and 1 month after uneventful photorefractive keratectomy (PRK) with the Multiscan laser (Schwind) in 10 eyes of 8 patients. The corrections ranged from -2.5 to -6.0 diopters, and ablation zones of 6.0 mm and larger were used. The measured wavefront errors were compared to numerical simulations using the individually determined decentrations and currently used ablation profiles. RESULTS: The PRK-induced aberrations were significantly greater than the preoperative aberrations. The numerically calculated increase in the higher-order optical aberrations correlated with the clinical results, demonstrating a major increase in coma- and spherical-like aberrations. Subclinical decentration (less than 1.0 mm) was found to be a major factor in increased coma-like and spherical-like aberrations after corneal laser surgery. CONCLUSION: To minimize higher-order optical errors, special efforts to center the ablation zone are necessary; for example, by eye-tracking systems that consider the visual axis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
LASIK and PRK in hyperopic astigmatic eyes: is early retreatment advisable?
Frings, A., Richard, G., Steinberg, J., Linke, S., Katz, T., & Druchkiv, V. (2016) · Clinical Ophthalmology · doi:10.2147/opth.s99098 · Cited by 29
Metadata
- Authors
- Mrochen, M., Kaemmerer, M., Mierdel, P., & Seiler, T.
- Venue
- Journal of Cataract and Refractive Surgery
- Published
- 2001-03
- Volume
- 27
- Issue
- 3
- Pages
- 362-369
- ISSN
- 0146-2776 (ISSN-L)
- 0886-3350
- OpenAlex
- W142203701
- Cited by
- 280
- References
- 0
- FWCI
- 13.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Increased higher-order optical aberrations after laser refractive surgery: A problem of subclinical decentration. https://app.cochat.ai/papers/10.1016/s0886-3350(00)00806-3
- The paper
- Mrochen, M., Kaemmerer, M., Mierdel, P., & Seiler, T. (2001). Increased higher-order optical aberrations after laser refractive surgery: A problem of subclinical decentration. Journal of Cataract and Refractive Surgery. https://doi.org/10.1016/s0886-3350(00)00806-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.