CoChat

Spot size and quality of scanning laser correction of higher-order wavefront aberrations

Huang, David, Arif, Muhammad · 2002 · Journal of Cataract and Refractive Surgery
Cited by 106

The DOI matches its Crossref record.

Abstract

PURPOSE: To investigate the effect of laser spot size on the outcome of aberration correction with scanning laser corneal ablation. SETTING: Cleveland Clinic Foundation, Cleveland, Ohio, USA. METHODS: Corrections of wavefront aberrations of Zernike modes from the second to eighth order were simulated. Gaussian and top-hat beams of 0.6 to 2.0 mm full-width-half-maximum diameters were modeled. The fractional correction and secondary aberration (distortion) were evaluated. RESULTS: Using a distortion/correction ratio of less than 0.5 as a cutoff for adequate performance, a 2.0 mm or smaller beam was adequate for spherocylindrical correction (Zernike second order), a 1.0 mm or smaller beam was adequate for correction of up to fourth-order Zernike modes, and a 0.6 mm or smaller beam was adequate for correction of up to sixth-order Zernike modes. CONCLUSIONS: Since ocular aberrations above the Zernike fourth order are relatively insignificant in normal eyes, current scanning lasers with a beam diameter of 1.0 mm or less are theoretically capable of eliminating most higher-order aberrations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0886-3350(01)01163-4

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 106

Metadata

Authors
Huang, D., & Arif, M.
Venue
Journal of Cataract and Refractive Surgery
Published
2002-03
Volume
28
Issue
3
Pages
407-416
ISSN
  • 0146-2776 (ISSN-L)
  • 0886-3350
OpenAlex
W1971817082
Cited by
106
References
0
FWCI
6.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Spot size and quality of scanning laser correction of higher-order wavefront aberrations. https://app.cochat.ai/papers/10.1016/s0886-3350(01)01163-4
The paper
Huang, D., & Arif, M. (2002). Spot size and quality of scanning laser correction of higher-order wavefront aberrations. Journal of Cataract and Refractive Surgery. https://doi.org/10.1016/s0886-3350(01)01163-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.