Spot size and quality of scanning laser correction of higher-order wavefront aberrations
The DOI matches its Crossref record.
Abstract
PURPOSE: To investigate the effect of laser spot size on the outcome of aberration correction with scanning laser corneal ablation. SETTING: Cleveland Clinic Foundation, Cleveland, Ohio, USA. METHODS: Corrections of wavefront aberrations of Zernike modes from the second to eighth order were simulated. Gaussian and top-hat beams of 0.6 to 2.0 mm full-width-half-maximum diameters were modeled. The fractional correction and secondary aberration (distortion) were evaluated. RESULTS: Using a distortion/correction ratio of less than 0.5 as a cutoff for adequate performance, a 2.0 mm or smaller beam was adequate for spherocylindrical correction (Zernike second order), a 1.0 mm or smaller beam was adequate for correction of up to fourth-order Zernike modes, and a 0.6 mm or smaller beam was adequate for correction of up to sixth-order Zernike modes. CONCLUSIONS: Since ocular aberrations above the Zernike fourth order are relatively insignificant in normal eyes, current scanning lasers with a beam diameter of 1.0 mm or less are theoretically capable of eliminating most higher-order aberrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wavefront-optimized ablation profiles: Theoretical background
Mrochen, M., Donitzky, C., Wüllner, C., & Löffler, J. (2004) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.01.026 · Cited by 209
Wavefront Ablation Profiles in Refractive Surgery: Description, Results, and Limitations
Smadja, D., Reggiani-Mello, G., Santhiago, M. R., & Krueger, R. R. (2012) · Journal of Refractive Surgery · doi:10.3928/1081597x-20120217-01 · Cited by 58
In Vivo Measurements of Thermal Load During Ablation in High-speed Laser Corneal Refractive Surgery
de Ortueta, D., Magnago, T., Triefenbach, N., Arba Mosquera, S., Sauer, U., & Brunsmann, U. (2012) · Journal of Refractive Surgery · doi:10.3928/1081597x-20110906-01 · Cited by 39
Mrochen, M., Schelling, U., Wuellner, C., & Donitzky, C. (2009) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2008.10.053 · Cited by 25
“Smaller spot sizes allow the correction of specific substructures of aberrations, which are of special interest in customized corneal laser surgery.(1,3) However, smaller spot sizes may lead to a significant increase in treatment time if the laser repetition rate is not increased.”
Background
Metadata
- Authors
- Huang, D., & Arif, M.
- Venue
- Journal of Cataract and Refractive Surgery
- Published
- 2002-03
- Volume
- 28
- Issue
- 3
- Pages
- 407-416
- ISSN
- 0146-2776 (ISSN-L)
- 0886-3350
- OpenAlex
- W1971817082
- Cited by
- 106
- References
- 0
- FWCI
- 6.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spot size and quality of scanning laser correction of higher-order wavefront aberrations. https://app.cochat.ai/papers/10.1016/s0886-3350(01)01163-4
- The paper
- Huang, D., & Arif, M. (2002). Spot size and quality of scanning laser correction of higher-order wavefront aberrations. Journal of Cataract and Refractive Surgery. https://doi.org/10.1016/s0886-3350(01)01163-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.