Flap dimensions created with the IntraLase FS laser

Binder, Perry S·2004·Journal of Cataract & Refractive Surgery

Abstract

PURPOSE: To assess the safety and predictability of the IntraLase femtosecond laser to create accurate flap thickness and diameter. SETTING: Clinical office-based practice. METHODS: In the first 103 eyes in which flaps were created with the IntraLase laser, the flap thickness was measured by the ultrasonic difference between the preoperative and post-flap-creation central corneal thickness and the flap diameter was measured with calipers. RESULTS: As the attempted flap thickness decreased from 140.0 microm to 110.0 microm in 10.0 microm increments, the mean flap thickness decreased from 132.5 microm to 125.0 microm, with standard deviations decreasing from +/-18.5 to +/-12.0 microm. The mean flap diameter differed from the attempted diameter by less than 0.03 microm in all but the 130.0 microm group. Two slipped flaps and 20 cases of interface inflammation occurred early in the series. CONCLUSIONS: The IntraLase laser, while adding technical complexity to the laser in situ keratomileusis procedure, is able to predictably create flap diameters, hinge location, and flap thickness while eliminating the risk for cap perforations. The technique of flap elevation affects rapidity of visual recovery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0886-3350(03)00578-9

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 254

Metadata

Authors
Binder, P. S.
Venue
Journal of Cataract & Refractive Surgery
Published
2004-01
Volume
30
Issue
1
Pages
26-32
ISSN
  • 0146-2776 (ISSN-L)
  • 0886-3350
OpenAlex
W2035734761
Cited by
254
References
5
FWCI
18.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Flap dimensions created with the IntraLase FS laser. https://app.cochat.ai/papers/10.1016/s0886-3350(03)00578-9
The paper
Binder, P. S. (2004). Flap dimensions created with the IntraLase FS laser. Journal of Cataract & Refractive Surgery. https://doi.org/10.1016/s0886-3350(03)00578-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.