The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Relationship between intraocular lens biomaterials and posterior capsule opacification
Abstract
PURPOSE: To determine whether posterior capsule opacification (PCO) is influenced by intraocular lens (IOL) material. SETTING: A British teaching hospital eye department. METHODS: Ninety eyes were prospectively randomized to receive a poly(methyl methacrylate) (PMMA), silicone, or AcrySof IOL. All lenses had 6.0 mm optics and PMMA haptics. A standardized surgical protocol was performed by a single surgeon using an extracapsular technique with capsulorhexis. Patients having surgical complications were excluded and all patients had standardized medication and follow-up. Posterior capsule opacification was assessed by a digital retroillumination camera using a dedicated software program based on the analysis of texture in the image and calculated as the percentage area of opacified capsule. Data were analyzed 2 years postoperatively. RESULTS: There was a significant difference in percentage of PCO at 2 years among the three lens types (P < .0001). The AcrySof lenses were associated with less PCO (median 11.75%) than PMMA (43.65%) and silicone (33.50%) lenses (P < .001 and P = .025, respectively). The difference between PMMA and silicone lenses was not statistically significant. CONCLUSION: Intraocular lenses made from AcrySof were associated with a significantly reduced degree of PCO.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Cited by
Posterior Capsular Opacification: A Problem Reduced but Not Yet Eradicated
Awasthi, N. (2009) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2009.3 · Cited by 385
Hollick, E. J., Spalton, D. J., Ursell, P. G., Pande, M. V., Barman, S. A., Boyce, J. F., & Tilling, K. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)90047-7 · Cited by 316
Self-citationPosterior capsule opacification
Wormstone, I. M., Wang, L., & Liu, C. S. C. (2009) · Experimental Eye Research · doi:10.1016/j.exer.2008.10.016 · Cited by 305
Metadata
- Authors
- Ursell, P. G., Spalton, D. J., Pande, M. V., Hollick, E. J., Barman, S., Boyce, J., & Tilling, K.
- Venue
- Journal of Cataract and Refractive Surgery
- Published
- 1998-03
- Volume
- 24
- Issue
- 3
- Pages
- 352-360
- ISSN
- 0146-2776 (ISSN-L)
- 0886-3350
- OpenAlex
- W2022413475
- Cited by
- 305
- References
- 1
- FWCI
- 22.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relationship between intraocular lens biomaterials and posterior capsule opacification. https://app.cochat.ai/papers/10.1016/s0886-3350(98)80323-4
- The paper
- Ursell, P. G., Spalton, D. J., Pande, M. V., Hollick, E. J., Barman, S., Boyce, J., & Tilling, K. (1998). Relationship between intraocular lens biomaterials and posterior capsule opacification. Journal of Cataract and Refractive Surgery. https://doi.org/10.1016/s0886-3350(98)80323-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.