Measurements of temperature distribution in ground
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The working principle of ground-source cooling is based on the fact that the ground temperature below approximately 10 m remains fairly constant all year round at about mean annual ambient air temperature [210].”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [210]
Citations
Cites
Analysis of heat and mass transfer
Eckert, E. R. G., & Drake, R. M. (1971) · Medical Entomology and Zoology · Cited by 1,993
On the application of the energy balance equation to predict ground temperature profiles
Mihalakakou, G. K., Santamouris, M., Lewis, J. O., & Asimakopoulos, D. N. (1997) · Solar Energy · doi:10.1016/s0038-092x(97)00012-1 · Cited by 209
Remote prediction of ground temperature in Australian soils and mapping its distribution
Baggs, S. A. (1983) · Solar Energy · doi:10.1016/0038-092x(83)90189-5 · Cited by 86
A new computerized approach to estimating the thermal properties of unfrozen soils
Tarnawski, V. R., & Wagner, B. (1992) · Canadian Geotechnical Journal · doi:10.1139/t92-079 · Cited by 47
Australian Earth-Covered Building
Baggs, S. A., Baggs, J. C., & Baggs, D. (1991) · Cited by 17
Cited by
Seawater desalination using renewable energy sources
KALOGIROU, S. (2005) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2005.03.001 · Cited by 1,169
“[192] present the temperature distributions measured in the ground for the period between summer 1999 to spring 2001.”
BackgroundGround heat exchangers—A review of systems, models and applications
Florides, G. A., & Kalogirou, S. A. (2007) · Renewable Energy · doi:10.1016/j.renene.2006.12.014 · Cited by 768
A comprehensive study of geothermal heating and cooling systems
Soltani, M., M. Kashkooli, F., Dehghani-Sanij, A. R., Kazemi, A. R., Bordbar, N., Farshchi, M. J., Elmi, M., Gharali, K., & B. Dusseault, M. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2018.09.036 · Cited by 257
“[136] set up two experimental stations with different surface covers, a car park as a “bare ground surface” having a solar radiation effect and a lawn in the city of Poznan, to investigate the ground cover effects on the ground temperature distribution.”
BackgroundNumerical and experimental analysis of a horizontal ground-coupled heat pump system
Esen, H., İnallı, M., & Esen, M. (2006) · Building and Environment · doi:10.1016/j.buildenv.2005.11.027 · Cited by 244
“In the literature, there are numerous experimental [1–10] and numerical [11–17] analysis of GCHPs.”
BackgroundZeng, Y.-C., Su, Z., & Wu, N.-Y. (2013) · Energy · doi:10.1016/j.energy.2013.04.055 · Cited by 199
An intense review on the latest advancements of Earth Air Heat Exchangers
Bordoloi, N., Sharma, A., Nautiyal, H., & Goel, V. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.03.056 · Cited by 189
Resilient cooling strategies – A critical review and qualitative assessment
Zhang, C., Kazanci, O. B., Levinson, R., Heiselberg, P., Olesen, B. W., Chiesa, G., Sodagar, B., Ai, Z., Selkowitz, S., Zinzi, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111312 · Cited by 180
de Moel, M., Bach, P. M., Bouazza, A., Singh, R. M., & Sun, J. O. (2010) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2010.07.027 · Cited by 178
“boundary conditions) determined by ambient air temperature, wind, solar radiation, relative humidity and rainfall [23,40,41].”
BackgroundOcłoń, P., Cisek, P., Pilarczyk, M., & Taler, D. (2015) · Energy Conversion and Management · doi:10.1016/j.enconman.2015.01.092 · Cited by 140
Wang, H., & Qi, C. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.11.009 · Cited by 137
Three-years operation experience of a ground source heat pump system in Northern Greece
Michopoulos, A. K., Bozis, D., Kikidis, P. S., Papakostas, K. T., & Kyriakis, N. A. (2006) · Energy and Buildings · doi:10.1016/j.enbuild.2006.08.002 · Cited by 128
“As a consequence, soil temperature is stabilized at the yearly average air temperature after the depth of about 10 m [1].”
BackgroundWater Desalination Using Geothermal Energy
Goosen, M., Mahmoudi, H., & Ghaffour, N. (2010) · Energies · doi:10.3390/en3081423 · Cited by 120
“[32] reported that one can distinguish three ground zones; surface, shallow and deep, with geothermal energy sources being classified in terms of their measured temperatures as low (<100 °C), medium”
BackgroundRazavi, S. H., Ahmadi, R., & Zahedi, A. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.10.003 · Cited by 120
Singh, R., Sawhney, R. L., Lazarus, I. J., & Kishore, V. V. N. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.08.058 · Cited by 116
Elminshawy, N. A. S., Siddiqui, F. R., & Addas, M. F. (2016) · Energy Conversion and Management · doi:10.1016/j.enconman.2016.08.044 · Cited by 115
Mahmoudi, H., Spahis, N., Goosen, M. F. A., Ghaffour, N., Drouiche, N., & Ouagued, A. (2009) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2009.07.038 · Cited by 112
“[17] reported on the temperature distribution measured in the ground during a two-year period.”
BackgroundDanielewicz, J., Śniechowska, B., Sayegh, M. A., Fidorόw-Kaprawy, N., & Jouhara, H. (2015) · Energy · doi:10.1016/j.energy.2015.07.012 · Cited by 113
Agrawal, K. K., Agrawal, G. D., Misra, R., Bhardwaj, M., & Jamuwa, D. K. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.07.035 · Cited by 116
Thermal Barrier as a technique of indirect heating and cooling for residential buildings
Krzaczek, M., & Kowalczuk, Z. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.12.002 · Cited by 98
“[7] investigate experimentally a temperature distribution in the ground outside the building basement for two different locations: car park and lawn.”
BackgroundInfluentialNatural convection in groundwater-filled boreholes used as ground heat exchangers
Spitler, J. D., Javed, S., & Ramstad, R. K. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.11.041 · Cited by 93
Applications of earth-to-air heat exchangers: A holistic review
Mihalakakou, G. K., Souliotis, M., Papadaki, M. I., Halkos, G., Paravantis, J. A., Makridis, S. S., & Papaefthimiou, S. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111921 · Cited by 110
A numerical model of a deeply buried air–earth–tunnel heat exchanger
Su, H., Liu, X., Ji, L., & Mu, J.-Y. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.01.029 · Cited by 86
The performance analysis of a new thermal backfill material for underground power cable system
Ocłoń, P., Marco Bittelli, A., Cisek, P., Kroener, E., Pilarczyk, M., Taler, D., Rao, R. V., & Vallati, A. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.07.102 · Cited by 85
Advances in standalone and hybrid earth-air heat exchanger (EAHE) systems for buildings: A review
Soares, N., Rosa, N., Monteiro, H., & Costa, J. J. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111532 · Cited by 83
Numerical and experimental study of geothermal heat extraction from backfilled mine stopes
Ghoreishi‐Madiseh, S. A., Hassani, F. P., & Abbasy, F. (2014) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2014.11.023 · Cited by 81
Wang, H., Qi, C., Wang, E., & Zhao, J. L. (2008) · Renewable Energy · doi:10.1016/j.renene.2008.04.024 · Cited by 81
RetractedHill, A. “., Laugier, E. J., & Casana, J. (2020) · Remote Sensing · doi:10.3390/rs12040690 · Cited by 80
Today's and Future Challenges in Applications of Renewable Energy Technologies for Desalination
Goosen, M. F. A., Mahmoudi, H., & Ghaffour, N. (2013) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2012.741313 · Cited by 80
“Popiel et al. (2001) reported that one can distinguish three ground zones, surface, shallow, and deep, with geothermal energy sources being classified in terms of their measured temperatures as low (<100◦C), medium (100–150◦C), and high temperature (>150◦C), respectively.”
BackgroundInfluence of coating soil types on the energy of earth-air heat exchanger
Cuny, M., Lin, J., Siroux, M., Magnenet, V., & Fond, C. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.10.048 · Cited by 74
Amanowicz, Ł. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.05.096 · Cited by 74
Annual ground temperature measurements at various depths
Florides, G. A., & Kalogirou, S. A. (2005) · Ktisis at Cyprus University of Technology (Cyprus University of Technology) · Cited by 72
Ocłoń, P., Cisek, P., Rerak, M., Taler, D., Rao, R. V., Vallati, A., & Pilarczyk, M. (2017) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2017.09.015 · Cited by 71
Amanowicz, Ł., & Wojtkowiak, J. (2017) · Thermal Science and Engineering Progress · doi:10.1016/j.tsep.2017.10.018 · Cited by 70
Self-citationSoil temperature calculation for burial site analysis
Prangnell, J., & McGowan, G. (2009) · Forensic Science International · doi:10.1016/j.forsciint.2009.07.002 · Cited by 73
“This was in agreement with previous research [26,27,29] which found that atmospheric heat is unable to penetrate in sufficient quantities to greatly alter soil temperature at such depths.”
ResultYu, X., Wang, R. Z., & Zhai, X. Q. (2010) · Energy · doi:10.1016/j.energy.2010.11.013 · Cited by 64
Lv, W., Li, A., Ma, J., Cui, H., Zhang, X., Zhang, W., & Guo, Y. (2020) · Sustainable Cities and Society · doi:10.1016/j.scs.2020.102107 · Cited by 64
Measurements of ground temperatures in Cyprus for ground thermal applications
Pouloupatis, P. D., Florides, G. A., & Tassou, S. A. (2010) · Renewable Energy · doi:10.1016/j.renene.2010.07.029 · Cited by 62
Tsilingiridis, G., & Papakostas, K. T. (2014) · Energy · doi:10.1016/j.energy.2014.07.004 · Cited by 61
Temperature distributions of ground in the urban region of Poznan City
Popiel, C. O., & Wojtkowiak, J. (2013) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2013.07.009 · Cited by 58
Self-citationAlves, A. B. M., & Schmid, A. L. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.12.025 · Cited by 56
Canham, C. A., Froend, R. H., Stock, W. D., & Davies, M. (2012) · Oecologia · doi:10.1007/s00442-012-2381-1 · Cited by 56
“The magnitude of diurnal and seasonal changes in soil temperature decreases with depth (Voroney 2007), and generally does not have an influence below 1 m (Popiel et al. 2001).”
BackgroundCooling potential of greening in the urban environment, a step further towards practice
Coccolo, S., Kämpf, J. H., Mauree, D., & Scartezzini, J. (2018) · Sustainable Cities and Society · doi:10.1016/j.scs.2018.01.019 · Cited by 59
Agrawal, K. K., Misra, R., & Agrawal, G. D. (2019) · Renewable Energy · doi:10.1016/j.renene.2019.08.044 · Cited by 56
Predicting the fluid temperature at the exit of the vertical ground heat exchangers
Michopoulos, A. K., & Kyriakis, N. A. (2009) · Applied Energy · doi:10.1016/j.apenergy.2009.02.002 · Cited by 54
Temperatures and stresses due to cement hydration on the R/C foundation of a wind tower—A case study
Azenha, M., & Faria, R. (2008) · Engineering Structures · doi:10.1016/j.engstruct.2008.01.018 · Cited by 53
Tinti, F., Barbaresi, A., Benni, S., Torreggiani, D., Bruno, R., & Tassinari, P. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.06.002 · Cited by 49
Ahmed, S. F., Khan, M. M. K., Oo, A. M. T., Rasul, M. G., & Hassan, N. M. S. (2021) · Renewable Energy · doi:10.1016/j.renene.2021.02.086 · Cited by 48
Temperatures and Heat Flows in a Soil Enclosing a Slinky Horizontal Heat Exchanger
Neuberger, P., Adamovský, R., & Šeďová, M. (2014) · Energies · doi:10.3390/en7020972 · Cited by 48
“The results of measurement of ground mass temperature [4] have indicated that the area up to 1 m deep is highly sensitive even to short-term variations of weather.”
BackgroundSakhri, N., Menni, Y., & Ameur, H. (2020) · Case Studies in Chemical and Environmental Engineering · doi:10.1016/j.cscee.2020.100013 · Cited by 49
Local warming of groundwaters caused by the urban heat island effect in Istanbul, Turkey
Yalçın, T., & Yetemen, Ö. (2009) · Hydrogeology Journal · doi:10.1007/s10040-009-0474-7 · Cited by 50
“According to the temperature distribution, ground zones are divided into three layers: a surface zone, a shallow zone and a deep zone (Popiel et al. 2001).”
BackgroundAgrawal, K. K., Misra, R., Agrawal, G. D., Bhardwaj, M., & Jamuwa, D. K. (2019) · International Journal of Green Energy · doi:10.1080/15435075.2019.1601096 · Cited by 45
“This sub-soil undisturbed temperature is equal to the temperature of the average ambient temperature on that latitude (Popiel, Wojtkowiak, and Biernacka 2001), and at a depth of 3–5 m it is observed to be 10–16°C in cold areas and 23–28°C in the warmer areas.”
BackgroundBelowground responses to altered precipitation regimes in two semi-arid grasslands
Holguin, J., Collins, S. L., & McLaren, J. R. (2022) · Soil Biology and Biochemistry · doi:10.1016/j.soilbio.2022.108725 · Cited by 47
Measurements of Ground Temperature at Various Depths
Florides, G. A., & Kalogirou, S. A. (2004) · Ktisis at Cyprus University of Technology (Cyprus University of Technology) · Cited by 43
Al-Hinti, I., Almuhtady, A., & Al-Kouz, W. G. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.05.107 · Cited by 43
Ground-Source Heat Pump Systems
Sârbu, I., & Sebarchievici, C. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-804220-5.00005-9 · Cited by 42
Benzaama, M.-H., Menhoudj, S., Lekhal, M. C., Mokhtari, A. M., & Attia, S. (2021) · Solar Energy · doi:10.1016/j.solener.2021.03.070 · Cited by 42
Staniec, M., & Nowak, H. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.05.047 · Cited by 46
Bryś, K., Bryś, T., Sayegh, M. A., & Ojrzyńska, H. (2019) · Renewable Energy · doi:10.1016/j.renene.2019.07.101 · Cited by 40
Ground temperature profiles and thermal rock properties at Wairakei, New Zealand
Manen, S. M. V., & Wallin, E. L. (2011) · Renewable Energy · doi:10.1016/j.renene.2011.11.032 · Cited by 37
“[2,3]): (1) the surface zone, where the ground temperature is sensitive to diurnal variations, (2) the shallow zone, where the ground is sensitive to seasonal weather variations and (3) a deep zone where the ground temperature is near constant.”
BackgroundKarabacak, R., Acar, Ş. G., Kumsar, H., Gökgöz, A., Kaya, M., & Tülek, Y. (2010) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2010.10.009 · Cited by 36
Landsat and Local Land Surface Temperatures in a Heterogeneous Terrain Compared to MODIS Values
Simó, G., García‐Santos, V., Jiménez, M. A., Martínez‐Villagrasa, D., Picos, R., Caselles, V., & Cuxart, J. (2016) · Remote Sensing · doi:10.3390/rs8100849 · Cited by 40
“Temperature usually varies very significantly with a height from this interface upwards in the lowest meters of the atmosphere [2], and the same happens as the progressively deeper layers in the soil are explored [3], with variations of contrary signs, with usually LST being the highest (lowest) value of the temperatu…”
BackgroundSubsurface shallow depth soil layers thermal potential for ground heat pumps in Poland
Bryś, K., Bryś, T., Sayegh, M. A., & Ojrzyńska, H. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.01.015 · Cited by 41
Ocłoń, P., Cisek, P., Taler, D., Pilarczyk, M., & Szwarc, T. (2015) · Energy · doi:10.1016/j.energy.2015.04.100 · Cited by 34
“[40] due to the possible adverse conditions of heat dissipation.”
BackgroundChen, J., & Jiang, F. (2015) · Heat and Mass Transfer · doi:10.1007/s00231-015-1554-y · Cited by 33
“Temperature values at the top and bottom x–z plane are fixed at 300 K [20] and 540 K, respectively; the geothermal gradient is assumed to be constant, 4 K/100 m [6].”
BackgroundRadioti, G., Sartor, K., Charlier, R., Dewallef, P., & Nguyen, F. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.05.070 · Cited by 33
Ma, L., Li, Y., Wang, J., Li, S., Zhao, J. L., Li, W., Zayed, M. E., Shao, Q., & Sun, M. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.04.014 · Cited by 33
Investigating the thermal behaviour of geothermal pavements using Thermal Response Test (TRT)
Motamedi, Y., Makasis, N., Gu, X., Narsilio, G. A., Arulrajah, A., & Horpibulsuk, S. (2021) · Transportation Geotechnics · doi:10.1016/j.trgeo.2021.100576 · Cited by 33
Measurement and Prediction of Undisturbed Underground Temperature Distribution
Cui, W., Liao, Q., Chang, G., Chen, G., Peng, Q., & Jen, T. (2011) · Volume 4: Energy Systems Analysis, Thermodynamics and Sustainability; Combustion Science and Engineering; Nanoengineering for Energy, Parts A and B · doi:10.1115/imece2011-63311 · Cited by 32
Amanowicz, Ł., & Wojtkowiak, J. (2020) · Renewable Energy · doi:10.1016/j.renene.2020.05.125 · Cited by 32
Self-citationExperimental analysis of thermal interaction between wine cellar and underground
Tinti, F., Barbaresi, A., Benni, S., Torreggiani, D., Bruno, R., & Tassinari, P. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.07.025 · Cited by 31
Heat losses in water pit thermal energy storage systems in the presence of groundwater
Sifnaios, I., Jensen, A. R., Furbo, S., & Fan, J. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.121382 · Cited by 30
Earth to Air Heat Exchanger and Its Applications in Arid Regions - An Updated Review
Sakhri, N., Menni, Y., Chamkha, A. J., Salmi, M., & Ameur, H. (2020) · TECNICA ITALIANA-Italian Journal of Engineering Science · doi:10.18280/ti-ijes.640113 · Cited by 29
“[30] conducted insitu soil measurements in Poland between the summer of 1999 and the spring of 2001.”
BackgroundGreco, A., & Masselli, C. (2020) · Energies · doi:10.3390/en13236414 · Cited by 38
Amanowicz, Ł., & Wojtkowiak, J. (2021) · Energies · doi:10.3390/en14248217 · Cited by 28
Self-citationXiao, H., & Huang, J. (2013) · Geotechnical Testing Journal · doi:10.1520/gtj20120096 · Cited by 27
A simple method for estimating transient heat transfer in slab-on-ground floors
Zhong, Z., & Braun, J. E. (2006) · Building and Environment · doi:10.1016/j.buildenv.2005.01.030 · Cited by 27
Ocùoñ, P., Taler, D., Cisek, P., & Pilarczyk, M. (2015) · Strength of Materials · doi:10.1007/s11223-015-9713-4 · Cited by 27
Application of Renewable Energies for Water Desalination
Goosen, M. F. A., Mahmoudi, H., Ghaffour, N., & Shyam, S. (2011) · InTech eBooks · doi:10.5772/14011 · Cited by 26
Introduction to Renewable Energy Powered Desalination
Kalogirou, S. A. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-815244-7.00001-5 · Cited by 24
Smolana, A., Klemczak, B., Azenha, M., & Schlicke, D. (2022) · Materials · doi:10.3390/ma15051815 · Cited by 24
“The second approach is based on the analytical calculations of the temperature distribution in the soil [45,50,51].”
BackgroundZhao, J., Huang, B., Li, Y., & Zhao, Y. (2024) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2024.103862 · Cited by 40
Experimental study on development of thermal conditions in ground beneath a greenhouse
Nawalany, G., Bieda, W., Radoń, J., & Herbut, P. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.10.020 · Cited by 22
“Temperature fluctuations are most significant in the top layer of the ground; whilst at the depth of around 10 m, ground temperature approximates the annual average temperature of air in the given area [5].”
BackgroundThermal and energy performance evaluation of underground bunkers: An adaptive reuse approach
Breçani, R., & Dervishi, S. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2019.101444 · Cited by 22
Yu, X., Zhai, X. Q., & Wang, R. Z. (2010) · Energy Conversion and Management · doi:10.1016/j.enconman.2010.03.009 · Cited by 22
Comparison of hygro-thermal conditions in underground wine cellars from a Spanish area
Silvia, M. O., & Guerrero, I. C. (2004) · Building and Environment · doi:10.1016/j.buildenv.2004.11.005 · Cited by 21
State-of-the-art of R&D on seawater desalination technology
Zheng, Z.-Y., Li, F., Li, Q., Wang, L., Cai, W., Li, X., & Zhang, H.-N. (2016) · Chinese Science Bulletin (Chinese Version) · doi:10.1360/n972015-00829 · Cited by 20
Hourly Simulation of an Earth-to-Air Heat Exchanger in a Low-Energy Residential Building
Michalak, P. (2022) · Energies · doi:10.3390/en15051898 · Cited by 18
Dehkordi, S. E., & Schincariol, R. A. (2014) · Canadian Geotechnical Journal · doi:10.1139/cgj-2012-0205 · Cited by 18
Distribution of the temperature field in a pavement structure
Sun, L. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-849908-5.00002-x · Cited by 18
Mengistu, A. G., Rensburg, L. D. V., & Mavimbela, S. S. W. (2018) · Geoderma Regional · doi:10.1016/j.geodrs.2018.e00190 · Cited by 17
Effect of surface cover on ground temperature season's fluctuations
Oleśkowicz-Popiel, C., Wojtkowiak, J., & Prętka, I. (2002) · Foundations of Civil and Environmental Engineering · Cited by 17
Self-citationNgarambe, J., Raj, S., & Yun, G. Y. (2025) · Sustainable Cities and Society · doi:10.1016/j.scs.2025.106153 · Cited by 16
Deep, helical, communal nesting and emergence in the sand monitor: ecology informing paleoecology?
Doody, J., McHenry, C., Brown, M., Canning, G., Vas, G., & Clulow, S. (2018) · Journal of Zoology · doi:10.1111/jzo.12543 · Cited by 13
Florides, G. A., Pouloupatis, P. D., Kalogirou, S. A., Messaritis, V., Panayides, I., Zomeni, Z., Partasides, G., Lizides, A., Sophocleous, E., & Koutsoumpas, K. (2012) · Renewable Energy · doi:10.1016/j.renene.2012.01.059 · Cited by 16
Agrawal, K. K., Misra, R., Bhardwaj, M., Agrawal, G. D., & Mathur, A. (2019) · Journal of Thermal Science and Engineering Applications · doi:10.1115/1.4042856 · Cited by 16
Coşkun, S., Pulat, E., ÜNLÜ, K., & Yamankaradeniz, R. (2007) · International Journal of Energy Research · doi:10.1002/er.1350 · Cited by 16
Sofyan, S. E., Riayatsyah, T. M. I., KHAİRİL, K., Hu, E. J., Tamlicha, A., Pahlefi, T. M. R., & Aditiya, H. B. (2024) · Results in Engineering · doi:10.1016/j.rineng.2024.102932 · Cited by 15
The Effect of Drying around Power Cables on the Vadose Zone Temperature
Hruška, M., Clauser, C., & Doncker, R. W. D. (2018) · Vadose Zone Journal · doi:10.2136/vzj2018.05.0105 · Cited by 15
“(The depth range with low thermal gradients could extend to below 5 m or even down to 20 m [as found by temperature monitoring in the studies in Poland by Popiel et al. (2001) and in Cyprus by Florides and Kalogirou (2007)].)”
BackgroundBuilding–Soil Thermal Interaction: A Case Study
Nawalany, G., & Sokołowski, P. (2019) · Energies · doi:10.3390/en12152922 · Cited by 15
“During the last decade, the use of renewable energy has grown from 250% to as high as 450%, depending on the world region [7].”
BackgroundRapid on-site evaluation of thermal comfort through heat capacity in buildings
Zayas, J. L. F., Porta-Gándara, M. Á., & del Valle, N. C. (2005) · Energy and Buildings · doi:10.1016/j.enbuild.2004.09.003 · Cited by 15
Metadata
- Authors
- Popiel, C. O., Wojtkowiak, J., & Biernacka, B.
- Affiliations
- Poznań University of Technology (PL)
- Bialystok University of Technology (PL)
- Corresponding author
- Popiel, C.O
- ORCID
- Wojtkowiak, J
- Venue
- Experimental Thermal and Fluid Science
- Publisher
- Elsevier BV
- Published
- 2001-11
- Volume
- 25
- Issue
- 5
- Pages
- 301-309
- ISSN
- 0894-1777 (ISSN-L)
- OpenAlex
- W2007907415
- Cited by
- 219
- References
- 5
- Citations by year
- 2026: 7 · 2025: 12 · 2024: 12 · 2023: 8 · 2022: 14 · 2021: 14 · 2020: 10 · 2019: 13 · 2018: 12 · 2017: 15 · 2016: 15 · 2015: 13 · 2014: 14 · 2013: 10 · 2012: 8
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Experimental Thermal and Fluid Science (publishedVersion)
- Topics
- Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Geothermal Energy Systems and Applications
- Physical Sciences › Engineering › Civil and Structural Engineering › Soil and Unsaturated Flow
- Physical Sciences › Environmental Science › Environmental Engineering › Urban Heat Island Mitigation
- Keywords
- ground temperature distribution, soil temperature, heat flux, seasonal temperature variation, ground heat exchangers, thermal energy storage, building heat loss, parking lots, Poznań
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.