Electronic pill-boxes in the evaluation of antihypertensive treatment compliance: comparison of once daily versus twice daily regimen
Open accessThe DOI matches its Crossref record.
Abstract
The objective was to compare the compliance of hypertensive patients treated with captopril twice daily or trandolapril once daily. After a 2-week placebo period, hypertensive patients (diastolic BP 95-115 mm Hg) were randomly allocated to trandolapril 2 mg once daily or to captopril 25 mg twice daily for 6 months. Trandolapril and captopril were packed in electronic pill-boxes equipped with a microprocessor that recorded date and time of each opening (MEMS). Patients' compliance was assessed both by standard pill-count and by electronic monitoring. Blood pressure was measured using a validated semi-automatic device at the end of the placebo period and of the treatment period. One hundred sixty-two patients entered the study. Compliance data were evaluable for 133 patients (62 in the captopril group and 71 in the trandolapril group). Treatment groups were comparable at baseline except for age (P = .046). Using electronic pill-box, overall compliance was 98.9% in the trandolapril group and 97.5% in the captopril group (P = .002). The percentage of missed doses was 2.6% in the trandolapril group and 3.3% in the captopril group (P = .06). The percentage of delayed doses was 1.8% in the trandolapril group and 11.7% in the captopril group (P = .0001). The percentage of correct dosing periods, ie, a period with only one correct recorded opening, was 94.0% in the trandolapril group and 78.1% in the captopril group (P = .0001). Results were unchanged when adjusted for age. At the end of the study, 41% of patients in the trandolapril group and 27% in the captopril group (NS) had their blood pressure normalized (systolic BP <140 and diastolic BP <90 mm Hg). In this 6-month study, the electronic pill-box allowed refined analysis of compliance of hypertensive patients. Patients' compliance with once daily trandolapril was higher than with twice daily captopril. The between-group difference is mainly explained by an increase in delayed doses in the twice daily group.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gazzard, B., & on behalf of the BHIVA Treatment Guidelines Writing Group (2008) · HIV Medicine · doi:10.1111/j.1468-1293.2008.00636.x · Cited by 1,089
Viswanathan, M., Golin, C. E., Jones, C. D., Ashok, M., Blalock, S. J., Wines, R. C. M., Coker-Schwimmer, E. J. L., Rosen, D. L., Sista, P., & Lohr, K. N. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-11-201212040-00538 · Cited by 754
Interventions used to improve control of blood pressure in patients with hypertension
Glynn, L. G., Murphy, A. W., Smith, S. M., Schroeder, K., & Fahey, T. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005182.pub4 · Cited by 668
Cramer, J. A., Benedict, Á., Muszbek, N., Keskinaslan, A., & Khan, Z. M. (2007) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2007.01630.x · Cited by 487
Schroeder, K., Fahey, T., & Ebrahim, S. (2004) · Archives of Internal Medicine · doi:10.1001/archinte.164.7.722 · Cited by 416
Metadata
- Authors
- Andrejak, M., Genes, N., Vaur, L., Poncelet, P., Clerson, P., & Carre, A.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-02-01
- Volume
- 13
- Issue
- 2
- Pages
- 184-190
- ISSN
- 0895-7061 (ISSN-L)
- 1941-7225
- OpenAlex
- W2008468980
- Cited by
- 95
- References
- 0
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electronic pill-boxes in the evaluation of antihypertensive treatment compliance: comparison of once daily versus twice daily regimen. https://app.cochat.ai/papers/10.1016/s0895-7061(99)00175-2
- The paper
- Andrejak, M., Genes, N., Vaur, L., Poncelet, P., Clerson, P., & Carre, A. (2000). Electronic pill-boxes in the evaluation of antihypertensive treatment compliance: comparison of once daily versus twice daily regimen. American Journal of Hypertension. https://doi.org/10.1016/s0895-7061(99)00175-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.