The DOI matches its Crossref record.
A new quantitative optical biosensor for protein characterisation
Open accessAbstract
A new optical biosensor is described based on a dual waveguide interferometric technique. By addressing the waveguide structure with alternate polarisations the optogeometrical properties (density and thickness) of adsorbed protein layers at the sensor (solid)-liquid interface have been determined. Differences in the waveguide mode dispersion between the transverse electric (TE) and transverse magnetic (TM) modes allow unique solutions for adlayer thickness and refractive index to be determined at all stages during the formation process. The technique has been verified using standard protein systems and by comparing the data with published work using X-ray crystallography and neutron reflection techniques. The data obtained was found to be in excellent agreement with previously reported X-ray experiments given that typical film thicknesses for streptavidin layers were in the range 5.5-6.5 nm compared with the short axis crystal structure of between 4.8 and 5.6 nm. The precision of the measurements taken was of the order of 40 pm with respect to adsorbed adlayer thicknesses. This biosensor approach provides measurements of both thickness and density of adlayers to a high precision, simultaneously and in real time enabling detail of the structure and function of proteins to be elucidated. From such data it is possible to obtain information on the orientation, distortion and efficiency of immobilisation procedures as well as the interaction event of interest. The technique is expected to find utility with those interested in protein structure and function. This is an area of growing importance within the life sciences as the demand for quantitative analytical techniques increases with the growth in "proteomics".
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sensitive optical biosensors for unlabeled targets: A review
Fan, X., White, I. M., Shopova, S. I., Zhu, H., Suter, J. D., & Sun, Y. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.05.022 · Cited by 2,187
DNA Biosensors and Microarrays
Sassolas, A., Leca-Bouvier, B. D., & Blum, L. J. (2008) · Chemical Reviews · doi:10.1021/cr0684467 · Cited by 1,246
Integrated planar optical waveguide interferometer biosensors: A comparative review
Kozma, P., Kehl, F., Ehrentreich-Förster, E., Stamm, C., & Bier, F. F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.02.049 · Cited by 324
Fast, Ultrasensitive Virus Detection Using a Young Interferometer Sensor
Ymeti, A., Greve, J., Lambeck, P. V., Wink, T., van Hövell, Beumer, Wijn, R. R., Heideman, R. G., Subramaniam, V., & Kanger, J. S. (2007) · Nano Letters · doi:10.1021/nl062595n · Cited by 287
Biosensors and Microfluidic Biosensors: From Fabrication to Application
Kulkarni, M. B., Ayachit, N. H., & Aminabhavi, T. M. (2022) · Biosensors · doi:10.3390/bios12070543 · Cited by 281
Metadata
- Authors
- Cross, G. H., Reeves, A. A., Brand, S., Popplewell, J. F., Peel, L. L., Swann, M. J., & Freeman, N. J.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2003-12
- Volume
- 19
- Issue
- 4
- Pages
- 383-390
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2032693278
- Cited by
- 219
- References
- 0
- FWCI
- 2.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new quantitative optical biosensor for protein characterisation. https://app.cochat.ai/papers/10.1016/s0956-5663(03)00203-3
- The paper
- Cross, G. H., Reeves, A. A., Brand, S., Popplewell, J. F., Peel, L. L., Swann, M. J., & Freeman, N. J. (2003). A new quantitative optical biosensor for protein characterisation. Biosensors and Bioelectronics. https://doi.org/10.1016/s0956-5663(03)00203-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.