Biosensor for direct determination of organophosphate nerve agents. 1. Potentiometric enzyme electrode
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Purification and Properties of the Phosphotriesterase from Pseudomonas diminuta
Dumas, D. P., Caldwell, S. R., Wild, J. R., & Raushel, F. M. (1989) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)47164-0 · Cited by 498
Characterization of the zinc binding site of bacterial phosphotriesterase.
Omburo, G. A., Kuo, J. M., Mullins, L. S., & Raushel, F. M. (1992) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)42207-7 · Cited by 325 · cited 2×
“OPH was purified from recombinantE. coli carrying plasmid pJK33 (obtained from Dr Jeffrey Karns, USDA, Beltsville, MD, USA) according to the reported protocol (Omburo et al., 1992).”
MethodBiosensors for chemical and biological agents of defence interest
Paddle, B. M. (1996) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(96)82333-5 · Cited by 240 · cited 1×
“This detection limit, however, is one to three orders of magnitude higher than for AChE-based biosensors (Paddle, 1996; Trojanowicz and Hitchman, 1996; Andres and Narayanaswamy, 1997; Danzer and Schwedt, 1996; Martorell et al., 1997; Palchetti et al., 1997).”
BackgroundMicrobiological and Biotechnological Aspects of Metabolism of Carbamates and Organophosphates
Chapalamadugu, S., & Chaudhry, G. R. (1992) · Critical Reviews in Biotechnology · doi:10.3109/07388559209114232 · Cited by 200 · cited 2×
“Organophosphorus (OP) compounds, are among the most toxic substances known (Donarski et al., 1989; Chapalamadugu and Chaudhry, 1992).”
BackgroundDetermination of anticholinesterase pesticides in real samples using a disposable biosensor
Palchetti, I., Cagnini, A., Del Carlo, M., Coppi, C., Mascini, M., & Turner, A. P. F. (1997) · Analytica Chimica Acta · doi:10.1016/s0003-2670(96)00418-7 · Cited by 190 · cited 5×
“duced by hydrolysis of butyrylthiocholine andpaminophenyl acetate, respectively, or hydrogen peroxide generated as a result of the oxidation of choline produced from acetylcholine hydrolysis in the presence of choline oxidase) (Skladal, 1991; Marty et al., 1992; Palleschi et al., 1992; Skladal and Mascini, 1992; La Ro…”
BackgroundInfluentialLewis, V. E., Donarski, W. J., Wild, J. R., & Raushel, F. M. (1988) · Biochemistry · doi:10.1021/bi00405a030 · Cited by 181 · cited 2×
“…been shown to effectively hydrolyse a range of organophosphate esters, pesticides such as parathion, coumaphos and acephate, and chemical warfare agents such as soman, sarin, VX and tabun (Lewis et al., 1988; Donarski et al., 1989; Dumas et al., 1989a, b, 1990; Dave et al., 1993; Lai et al., 1994).”
BackgroundFibre-optic pesticide biosensor based on covalently immobilized acetylcholinesterase and thymol blue
Andres, R. T., & Narayanaswamy, R. (1997) · Talanta · doi:10.1016/s0039-9140(96)02071-1 · Cited by 101 · cited 3×
“…the enzyme reactivation step is excluded and is hence unsuitable for multiple use on-line process monitoring) to up to 5 h (Tran-Minh et al., 1990; Marty et al., 1992; Trettnak et al., 1993; La Rosa et al., 1994; Diehl-Faxon et al., 1996; Andres and Narayanaswamy, 1997; Palchetti et al., 1997).”
BackgroundCaldwell, S. R., & Raushel, F. M. (1991) · Biotechnology and Bioengineering · doi:10.1002/bit.260370203 · Cited by 97 · cited 2×
“Simulated samples representing the feed to a biological (enzymatic/microbial) biodetoxification process (Caldwell and Raushel, 1991; Chen and Mulchandani, 1998) were analysed using the enzyme electrode and conventional enzymatic assay (based on the concentration ofp-nitrophenol formed by enzymatic…”
BackgroundMethodThe use of live biocatalysts for pesticide detoxification
Chen, W., & Mulchandani, A. (1998) · Trends in biotechnology · doi:10.1016/s0167-7799(97)01160-8 · Cited by 89 · cited 2×
“Simulated samples representing the feed to a biological (enzymatic/microbial) biodetoxification process (Caldwell and Raushel, 1991; Chen and Mulchandani, 1998) were analysed using the enzyme electrode and conventional enzymatic assay (based on the concentration ofp-nitrophenol formed by enzymatic…”
MethodSelf-citationPollema, C. H., & Růžička, J. (1994) · Analytical Chemistry · doi:10.1021/ac00083a008 · Cited by 76 · cited 2×
“Immunoassays (1) require long analysis time (1– 2 h) and extensive sample handling (large number of washing steps); (2) require a considerable quantity of costly plastic trays that need to be disposed of in an environmentally acceptable, expensive manner (Pollema and Ruzicka, 1994); and (3) are unsuitable for on-line…”
BackgroundBastos, V. L. F. C., Bastos, J. C., Lima, J., & Faria, M. V. C. (1991) · Water Research · doi:10.1016/0043-1354(91)90164-l · Cited by 57 · cited 1×
“…et al., 1997; Palchetti et al., 1997), potentiometric (measuring the pH change as a result of acetic acid production) (Tran-Minh et al., 1990; Chuna Bastos et al., 1991; Kumaran and Tran-Minh, 1992; Kumaran and Morita, 1995; Danzer and Schwedt, 1996), conductometric (Dzyadevich et al.,…”
BackgroundCoppella, S. J., Delacruz, N., Payne, G. F., Pogell, B. M., Speedie, M. K., Karns, J. S., Sybert, E. M., & Connor, M. A. (1990) · Biotechnology Progress · doi:10.1021/bp00001a012 · Cited by 43 · cited 2×
“These concerns have stimulated the development of technologies to treat effluents generated at both the producer and consumer levels effectively (Munnecke, 1980; Coppella et al., 1990; Caldwell and Raushel, 1991; Grice et al., 1996; Mulbury et al., 1996; LeJeune et al., 1997).”
BackgroundMulbry, W. W., Valle, P. L. D., & Karns, J. S. (1996) · Pesticide Science · doi:10.1002/(sici)1096-9063(199610)48:2<149::aid-ps453>3.0.co;2-6 · Cited by 41 · cited 1×
“These concerns have stimulated the development of technologies to treat effluents generated at both the producer and consumer levels effectively (Munnecke, 1980; Coppella et al., 1990; Caldwell and Raushel, 1991; Grice et al., 1996; Mulbury et al., 1996; LeJeune et al., 1997).”
Background
Cited by
Microbial degradation of organophosphorus compounds
Singh, B. K., & Walker, A. (2006) · FEMS Microbiology Reviews · doi:10.1111/j.1574-6976.2006.00018.x · Cited by 1,013
Destruction and Detection of Chemical Warfare Agents
Kim, K., Tsay, O. G., Atwood, D. A., & Churchill, D. G. (2011) · Chemical Reviews · doi:10.1021/cr100193y · Cited by 1,011
Immunosensors—principles and applications to clinical chemistry
Luppa, P. B., Sokoll, L. J., & Chan, D. W. (2001) · Clinica Chimica Acta · doi:10.1016/s0009-8981(01)00629-5 · Cited by 741
Toxicity, monitoring and biodegradation of organophosphate pesticides: A review
Sidhu, G. K., Singh, S., Kumar, V., Dhanjal, D. S., Datta, S., & Singh, J. (2019) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2019.1565554 · Cited by 492
Bio-sensing of organophosphorus pesticides: A review
Pundir, C. S., Malik, A., & Preety (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111348 · Cited by 442
Metadata
- Authors
- Mulchandani, P., Mulchandani, A., Kaneva, I., & Chen, W.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 1999-01
- Volume
- 14
- Issue
- 1
- Pages
- 77-85
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2134116635
- Cited by
- 191
- References
- 13
- FWCI
- 9.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.