Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 158

The DOI matches its Crossref record.

Twenty years experience with pediatric pacing: epicardial and transvenous stimulation

Open access
Sachweh, J·2000·European Journal of Cardio-Thoracic Surgery

Abstract

OBJECTIVE: Permanent cardiac pacing in children and adolescents is rare and often occurs by means of epicardial pacing. Based on two decades of experience, operative and postoperative data of patients with epicardial and transvenous pacing were analyzed retrospectively. METHODS: Between October 1979 and December 1998, 71 patients (mean age, 5.3+/-4.2, range, 1 day-16.2 years; mean body weight, 18+/-12; range, 8-56 kg) underwent permanent pacemaker implantation. Indications were sinus node dysfunction and atrio-ventricular block following surgery for congenital heart disease (69%), or congenital atrioventricular block (31%). Pacing was purely atrial (1.4%), purely ventricular (73%), ventricular with atrial synchronization (5. 6%), or atrioventricular synchronized (20%). Epicardial pacing was established in 49 (69%), transvenous in 22 (31%) patients. Follow-up was 3.4+/-3.8 years (epicardial) and 3.0+/-4.0 years (transvenous). RESULTS: Epicardial leads were implanted in younger patients (mean age: 4.5 vs. 7.0 years, P<0.05) and preferably after surgery induced atrioventricular block (78 vs. 46%, P<0.05). The youngest patient with transvenous pacing was 1.3 years old (weight, 8.5 kg). At implantation epicardial ventricular stimulation threshold at 1.0 ms was 1.07+/-0.46 vs. 0.53+/-0.31 V (transvenous) (P<0.05). The age-adjusted rate of lead-related reoperations was significantly higher in patients with epicardial leads (P<0.05), mainly due to increasing chronic stimulation thresholds resulting in early battery depletion. In three patients who received steroid-eluting epicardial leads initial low thresholds persisted after five month to one years. In two patients with recurrent epicardial threshold increase, steroid-eluting epicardial leads led to good acute and chronic thresholds after nine to 15 month. Two post-operative death (2.8%) were probably due to a dysfunction of the (epicardial) pacing system. CONCLUSIONS: Transvenous pacing in the pediatric population is associated with a lower acute stimulation threshold and a lower rate of lead-related complications. If epicardial pacing is necessary (e. g. small body weight, special intracardiac anatomy (e.g. Fontan), impossible access to superior caval vein), steroid-eluting leads may be considered.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s1010-7940(00)00364-x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 158

Metadata

Authors
Sachweh, J.
Venue
European Journal of Cardio-Thoracic Surgery
Published
2000-04-01
Volume
17
Issue
4
Pages
455-461
ISSN
1010-7940 (ISSN-L)
OpenAlex
W2167218428
Cited by
158
References
0
FWCI
2.12
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Twenty years experience with pediatric pacing: epicardial and transvenous stimulation. https://app.cochat.ai/papers/10.1016/s1010-7940(00)00364-x
The paper
Sachweh, J. (2000). Twenty years experience with pediatric pacing: epicardial and transvenous stimulation. European Journal of Cardio-Thoracic Surgery. https://doi.org/10.1016/s1010-7940(00)00364-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.