Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 182

The DOI matches its Crossref record.

The efficacy of the Cox/maze procedure combined with mitral valve surgery: a matched control study

Open access
Raanani, Ehud, Albage, Anders, David, Tirone E., Yau, Terrence M., Armstrong, Susan·2001·European Journal of Cardio-Thoracic Surgery

Abstract

OBJECTIVE: To evaluate the results of the maze procedure combined with mitral valve (MV) surgery in patients with chronic atrial fibrillation (AF). METHODS: From 1994--1999, 47 patients with chronic AF underwent the maze procedure combined with MV surgery (maze group). They were compared to 47 patients matched for age, sex, left ventricular function and type of MV surgery (non-maze group). The maze group had less severe symptoms but larger left atrium, and AF of longer duration than the non-maze group. One surgeon performed all operations in both groups of patients. RESULTS: There were two early deaths in the maze group (4.5%) and one (2.2%) in the non-maze group. The duration of cardiopulmonary bypass (P=0.0001) and aortic crossclamping (P=0.0001) were greater in the maze group. Mean follow-up was 26+/-3 months in the maze group and 32+/-4 months in the non-maze group, and was 100% complete. Three-year survival was 96+/-3% for the maze group compared to 85+/-7% for the non-maze group (P=0.16). At the latest follow-up, 75% of the maze patients were in sinus rhythm compared to 36% of the non-maze patients (P=0.0004); 38% of the maze group were on coumadin postoperatively, compared to 69% in the non-maze group (P=0.003); and patients in the maze group were on fewer antiarrhythmic medications (P=0.0002). Three-year freedom from thromboembolic complications was 100% for the maze group compared to 83+/-7% for the non-maze group (P=0.03). CONCLUSIONS: In this retrospective study the maze procedure did not seem to increase operative mortality of MV surgery, was effective in eliminating atrial fibrillation, and reduced the risk of thromboembolic complications and the need for long-term anticoagulation after mitral valve repair or replacement with a bioprosthesis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s1010-7940(01)00576-0

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 182

Metadata

Authors
Raanani, E., Albage, A., David, T. E., Yau, T. M., & Armstrong, S.
Venue
European Journal of Cardio-Thoracic Surgery
Published
2001-04
Volume
19
Issue
4
Pages
438-442
ISSN
  • 1010-7940 (ISSN-L)
  • 1873-734X
OpenAlex
W2142340735
Cited by
182
References
0
FWCI
4.31
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The efficacy of the Cox/maze procedure combined with mitral valve surgery: a matched control study. https://app.cochat.ai/papers/10.1016/s1010-7940(01)00576-0
The paper
Raanani, E., Albage, A., David, T. E., Yau, T. M., & Armstrong, S. (2001). The efficacy of the Cox/maze procedure combined with mitral valve surgery: a matched control study. European Journal of Cardio-Thoracic Surgery. https://doi.org/10.1016/s1010-7940(01)00576-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.