CoChat

Thirty-day mortality and long-term survival following surgery for prosthetic endocarditis: a study from the UK heart valve registry1

Open access
Edwards, Maria-Benedicta, Ratnatunga, Chandana P., Dore, Caroline J., Taylor, Kenneth M. · 1998 · European Journal of Cardio-Thoracic Surgery
Cited by 105

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To assess the 30-day mortality, long-term survival and freedom from reoperation following surgery for prosthetic endocarditis (PVE). METHOD: A retrospective analysis of data from the UK Heart Valve Registry of 322 patients who had undergone single mechanical/bioprosthetic valve replacement for PVE between 1 January 1986 and 31 December 1996. The mean age was 54.9 +/- 12.8 years and 213 (66.1%) were males. There were 170 aortic and 152 mitral valve implantations. Eighty-five (26%) of the infected valves were bioprosthetic and 237 (74%) were mechanical. Of the new prostheses implanted 53 (17%) were bioprosthetic and 269 (83%) were mechanical. Of those with infected bioprostheses, 50 (15.2%) had mechanical valves at redo surgery, whilst 219 (68.3%) of infected mechanical prostheses were re-replaced by mechanical prostheses. The follow-up was 98% complete with a total of 1084.9 patient years. RESULTS: The 30-day mortality was 63 (19.9%; 95%CI 15.9-24.7%). There were 85 late deaths. One, 5 and 10 year survival rates were 67.1% (61.6-72.0%), 55.0% (49.0-60.7%) and 37.6% (27.9-47.2%), respectively. Age was the only significant determinant of 30-day mortality (P = 0.04). Age (P = 0.001) and explanting of infected bioprosthesis and replacement by mechanical valve (P = 0.04) determined long-term survival (P = 0.001). The incidence of re-reoperation was 9.9%. Freedom from reoperation for PVE was 88.4, 87.3 and 87.3% at 1, 5 and 10 years, respectively. Explanting of bioprosthesis and replacement by mechanical valve (P < 0.001) and reoperation within 60 days of native valve replacement (P = 0.02) were determinants of reoperation for PVE. Freedom from death or reoperation was 61.1, 50.6 and 34.2% at 1, 5 and 10 years, respectively. Age (P = 0.003), explanting of bioprosthesis and replacement by mechanical valve (P = 0.002) and the period between prosthetic re-replacement (P = 0.04) determined freedom from death or reoperation. CONCLUSION: Operation for PVE carries a high 30-day mortality and reduced long-term survival. There is no evidence that type of prosthesis used for re-reoperation determines survival or freedom from re-reoperation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s1010-7940(98)00148-1

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Aortic valve infection

    McGiffin, D. C., Galbraith, A. J., McLachlan, G. J., Stower, R. E., Wong, M. L., Stafford, E. G., Gardner, M. A. H., Pohlner, P. G., & O’Brien, M. F. (1992) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)34813-5 · Cited by 113 · cited 1×

    “In the context of PVE surgery, this is particularly relevant, because of the growing school of opinion that promotes the use of the homograft [5,18] or autograft [12] in this condition.”
    Background

Cited by

See all 105

Metadata

Authors
Edwards, M.-B., Ratnatunga, C. P., Dore, C. J., & Taylor, K. M.
Venue
European Journal of Cardio-Thoracic Surgery
Published
1998-08
Volume
14
Issue
2
Pages
156-164
ISSN
  • 1010-7940 (ISSN-L)
  • 1873-734X
OpenAlex
W2128176069
Cited by
105
References
1
FWCI
3.21
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.