The Development of the Maze Procedure for the Treatment of Atrial Fibrillation
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
The Maze procedure was developed for the treatment of atrial fibrillation over a period of several years. Extensive experimental and clinical studies of the underlying electrophysiology of the arrhythmia were performed, and numerous surgical techniques and principles were tried before the Maze procedure was conceived. Few cardiac surgical procedures have undergone more extensive research and experimental trials before being applied clinically. This article gives a brief summary of the work leading up to the eventual Maze-III procedure that is now in clinical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The surgical treatment of atrial fibrillation
Cox, J. L., Schuessler, R. B., D’Agostino, H. J., Stone, C. M., Chang, B.-C., Cain, M. E., Corr, P. B., & Boineau, J. P. (1991) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)36684-x · Cited by 1,464
Self-citationScheinman, M. M. (1982) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1982.03330070039027 · Cited by 836
Cox, J. L., Canavan, T. E., Schuessler, R. B., CAIN, M. E., Lindsay, B. D., Stone, C. M., Smith, P. K., Corr, P. B., & Boineau, J. P. (1991) · PubMed · Cited by 682
Self-citationModification of the maze procedure for atrial flutter and atrial fibrillation
Cox, J. L., Boineau, J. P., Schuessler, R. B., Jaquiss, R. D. B., & Lappas, D. G. (1995) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(95)70244-x · Cited by 500
Self-citationThe surgical treatment of atrial fibrillation
Cox, J. L., Canavan, T. E., Schuessler, R. B., Cain, M. E., Lindsay, B. D., Stone, C., Smith, P. K., Corr, P. B., & Boineau, J. P. (1991) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)36723-6 · Cited by 496
Self-citationModification of the maze procedure for atrial flutter and atrial fibrillation
Cox, J. L., Jaquiss, R. D. B., Schuessler, R. B., & Boineau, J. P. (1995) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(95)70245-8 · Cited by 486
Self-citationThe surgical treatment of atrial fibrillation. IV. Surgical technique.
Cox, J. L. (1991) · PubMed · Cited by 480
Self-citationThe surgical treatment of atrial fibrillation
Cox, J. L. (1991) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)36685-1 · Cited by 445
Self-citationLeft atrial isolation: new technique for the treatment of supraventricular arrhythmias.
Williams, J. M., Ungerleider, R. M., Lofland, G. K., et al. (1980) · PubMed · Cited by 283
Allessie, M. A., Lammers, W. J., Bonke, I. M., & Hollen, J. (1984) · Circulation · doi:10.1161/01.cir.70.1.123 · Cited by 275
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
HAÏSSAGUERRE, M., SANDERS, P., HOCINI, M., TAKAHASHI, Y., ROTTER, M., SACHER, F., ROSTOCK, T., HSU, L., BORDACHAR, P., REUTER, S., et al. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00307.x · Cited by 675
Mother rotors and fibrillatory conduction: a mechanism of atrial fibrillation
Jalife, J. (2002) · Cardiovascular Research · doi:10.1016/s0008-6363(02)00223-7 · Cited by 587
Surgical ablation of atrial fibrillation during mitral-valve surgery
Gillinov, A. M., Gelijns, A. C., Parides, M. K., DeRose, J. J., Moskowitz, A. J., Voisine, P., Ailawadi, G., Bouchard, D., Smith, P. K., Mack, M. J., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1500528 · Cited by 490
Surgical treatment of atrial fibrillation; a systematic review☆
Khargi, K., Hutten, B. A., Lemke, B., & Deneke, T. (2005) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2004.11.003 · Cited by 305
Surgery for permanent atrial fibrillation: impact of patient factors and lesion set
Gillinov, A. M., Bhavani, S., Blackstone, E. H., Rajeswaran, J., Svensson, L. G., Navia, J. L., Pettersson, B. G., Sabik, J. F., Smedira, N. G., Mihaljevic, T., et al. (2006) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2006.02.030 · Cited by 203
“These were performed as escribed by Cox and included cut-and-sew and cryohermy techniques and a biatrial lesion set [1].”
MethodInfluentialLeft Atrial Volume Is a Predictor of Atrial Fibrillation Recurrence After Catheter Ablation
Shin, S.-H., Park, M.-Y., Oh, W.-J., Hong, S.-J., Pak, H.-N., Song, W.-H., Lim, D.-S., Kim, Y.-H., & Shim, W.-J. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.10.022 · Cited by 168
Gillinov, A. M., Bakaeen, F., McCarthy, P. M., Blackstone, E. H., Rajeswaran, J., Pettersson, G., Sabik, J. F., Najam, F., Hill, K. M., Svensson, L. G., et al. (2006) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2005.04.060 · Cited by 76
Thoracoscopic surgical ablation versus catheter ablation for atrial fibrillation
Phan, K., Phan, S., Thiagalingam, A., Medi, C., & Yan, T. D. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezv180 · Cited by 76
Metadata
- Authors
- Cox, J. L., Schuessler, R. B., & Boineau, J. P.
- Venue
- Seminars in Thoracic and Cardiovascular Surgery
- Publisher
- Elsevier BV
- Published
- 2000-01
- Volume
- 12
- Issue
- 1
- Pages
- 2-14
- ISSN
- 1043-0679 (ISSN-L)
- OpenAlex
- W2077456907
- Cited by
- 194
- References
- 28
- FWCI
- 2.82
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.