The DOI matches its Crossref record.
Electron capture dissociation of gaseous multiply charged ions by Fourier-transform ion cyclotron resonance
Abstract
Fourier-transform ion cyclotron resonance instrumentation is uniquely applicable to an unusual new ion chemistry, electron capture dissociation (ECD). This causes nonergodic dissociation of far larger molecules (42 kDa) than previously observed (<1 kDa), with the resulting unimolecular ion chemistry also unique because it involves radical site reactions for similarly larger ions. ECD is highly complementary to the well known energetic methods for multiply charged ion dissociation, providing much more extensive protein sequence information, including the direct identification of N- versus C-terminal fragment ions. Because ECD only excites the molecule near the cleavage site, accompanying rearrangements are minimized. Counterintuitively, cleavage of backbone covalent bonds of protein ions is favored over that of noncovalent bonds; larger (>10 kDa) ions give far more extensive ECD if they are first thermally activated. This high specificity for covalent bond cleavage also makes ECD promising for studying the secondary and tertiary structure of gaseous protein ions caused by noncovalent bonding.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
‘Top down’ protein characterization via tandem mass spectrometry
Reid, G. E., & McLuckey, S. A. (2002) · Journal of Mass Spectrometry · doi:10.1002/jms.346 · Cited by 285
Metadata
- Authors
- McLafferty, F. W., Horn, D. M., Breuker, K., Ge, Y., Lewis, M. A., Cerda, B., Zubarev, R. A., & Carpenter, B. K.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-03-01
- Volume
- 12
- Issue
- 3
- Pages
- 245-249
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W1983191700
- Cited by
- 243
- References
- 0
- FWCI
- 11.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electron capture dissociation of gaseous multiply charged ions by Fourier-transform ion cyclotron resonance. https://app.cochat.ai/papers/10.1016/s1044-0305(00)00223-3
- The paper
- McLafferty, F. W., Horn, D. M., Breuker, K., Ge, Y., Lewis, M. A., Cerda, B., Zubarev, R. A., & Carpenter, B. K. (2001). Electron capture dissociation of gaseous multiply charged ions by Fourier-transform ion cyclotron resonance. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/s1044-0305(00)00223-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.