The DOI matches its Crossref record.
Improved ion extraction from a linear octopole ion trap: SIMION analysis and experimental demonstration
Abstract
Externally generated ions are accumulated in a linear octopole ion trap before injection into our 9.4 T Fourier transform ion cyclotron resonance (FT-ICR) mass analyzer. Such instrumental configuration has previously been shown to provide improved sensitivity, scan rate, and duty cycle relative to accumulated trapping in the ICR cell. However, inefficient ion ejection from the octopole currently limits both detection limit and scan rate. SIMION 7.0 analysis predicts that a dc axial electric field inside the linear octopole ion trap expedites and synchronizes the efficient extraction of the octopole-accumulated ions. Further SIMION analysis optimizes the ion ejection properties of each of three electrode configurations designed to produce a near-linear axial potential gradient. More efficient extraction and transfer of accumulated ions spanning a wide m/z range promises to reduce detection limit and increase front-end sampling rate (e.g., to increase front-end resolution for separation techniques coupled with FT-ICR mass analysis). Addition of the axial field improves experimental signal-to-noise ratio by more than an order of magnitude.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Applications of a travelling wave‐based radio‐frequency‐only stacked ring ion guide
Giles, K., Pringle, S. D., Worthington, K. R., Little, D., Wildgoose, J. L., & Bateman, R. H. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1641 · Cited by 727
Organic coating on biochar explains its nutrient retention and stimulation of soil fertility
Hagemann, N., Joseph, S., Schmidt, H.-P., Kammann, C. I., Harter, J., Borch, T., Young, R. B., Varga, K., Taherymoosavi, S., Elliott, K. W., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-01123-0 · Cited by 616
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
“Significant advances to FT-ICR technology, often focused on improving the analysis of intact proteins, included increases in magnetic field [88,89], addition of a resolving quadrupole for mass selection [90], and an accumulation octupole for ion storage before transmission to the ICR cell [91,92].”
Linear ion traps in mass spectrometry
Douglas, D. J., Frank, A. J., & Mao, D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20004 · Cited by 459
High-Resolution Mass Spectrometers
Marshall, A. G., & Hendrickson, C. L. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112945 · Cited by 394
Self-citation
Metadata
- Authors
- Wilcox, B. E., Hendrickson, C. L., & Marshall, A. G.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-11-01
- Volume
- 13
- Issue
- 11
- Pages
- 1304-1312
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2092454372
- Cited by
- 165
- References
- 0
- FWCI
- 6.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved ion extraction from a linear octopole ion trap: SIMION analysis and experimental demonstration. https://app.cochat.ai/papers/10.1016/s1044-0305(02)00622-0
- The paper
- Wilcox, B. E., Hendrickson, C. L., & Marshall, A. G. (2002). Improved ion extraction from a linear octopole ion trap: SIMION analysis and experimental demonstration. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/s1044-0305(02)00622-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.