The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Conformer-dependent proton-transfer reactions of ubiquitin ions
Abstract
The conformations of ubiquitin ions before and after being exposed to proton transfer reagents have been studied by using ion mobility/mass spectrometry techniques. Ions were produced by electrospray ionization and exposed to acetone, acetophenone, n-butylamine, and 7-methyl-1,5,7-triazabicyclo[4.4.0]dec-5-ene. Under the conditions employed, the +4 to +13 charge states were formed and a variety of conformations, which we have characterized as compact, partially folded, and elongated, have been observed. The low charge state ions have cross sections that are similar to those calculated for the crystal conformation. High charge states favor unfolded conformations. The ion mobility distributions recorded after ions have been exposed to each base show that the lowest charge state that is formed during proton-transfer reactions favors a compact conformation. More open conformations are observed for the higher charge states that remain after reaction. The results show that for a given charge state, the apparent gas-phase acidities of the different conformations are ordered as compact < partially folded < elongated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Cited by
Recommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
Self-citationIon mobility mass spectrometry of proteins and proteinassemblies
Uetrecht, C., Rose, R. J., van Duijn, E., Lorenzen, K., & Heck, A. J. R. (2010) · Chem. Soc. Rev. · doi:10.1039/b914002f · Cited by 462
Breuker, K., & McLafferty, F. W. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0807005105 · Cited by 423
Wyttenbach, T., & Bowers, M. T. (2011) · The Journal of Physical Chemistry B · doi:10.1021/jp206867a · Cited by 346
Breuker, K., Oh, H., Horn, D. M., Cerda, B. A., & McLafferty, F. W. (2002) · Journal of the American Chemical Society · doi:10.1021/ja012267j · Cited by 324
Metadata
- Authors
- Valentine, S. J., Counterman, A. E., & Clemmer, D. E.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-09-01
- Volume
- 8
- Issue
- 9
- Pages
- 954-961
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2036734090
- Cited by
- 230
- References
- 2
- FWCI
- 5.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Conformer-dependent proton-transfer reactions of ubiquitin ions. https://app.cochat.ai/papers/10.1016/s1044-0305(97)00085-8
- The paper
- Valentine, S. J., Counterman, A. E., & Clemmer, D. E. (1997). Conformer-dependent proton-transfer reactions of ubiquitin ions. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/s1044-0305(97)00085-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.