Calcium-induced noncovalently linked tetramers of MRP8 and MRP14 detected by ultraviolet matrix-assisted laser desorption/ionization mass spectrometry
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
MRP8 and MRP14 are members of the S100 family of calcium-binding proteins which play an important role during calcium-induced activation of phagocytes. Both proteins form noncovalently associated complexes as a prerequisite for biological functions. The exact stoichiometric composition of these complexes, however, has not been completely clarified yet. In the present study we show for the first time by ultraviolet matrix-assisted laser desorption/ionization mass spectrometry (UV-MALDI-MS) the calcium-induced formation of noncovalently associated (MRP8/MRP14)2 tetramers. Furthermore, we could determine posttranslational modifications of MRP8 and MRP14, the stoichiometric proportion of the two known MRP14 isoforms in the complexes as well as the number of calcium ions bound to the single MRP8 and MRP14 monomers and tetramers. MRP14 showed a higher affinity for calcium than MRP8. Upon complex formation the calcium binding increased to maximal saturation of the known EF hands in the complexed forms. Calcium-induced stabilization of the MRP8/MRP14 complexes was confirmed by DSC studies. Our results extend scope and application of UV-MALDI-MS by allowing identification of noncovalent protein complexes, the identification of minor alterations of subunits in such complexes as well as the determination of bound calcium ions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Self-citationDale, I., Brandtzaeg, P., Fagerhol, M. K., & Scott, H. (1985) · American Journal of Clinical Pathology · doi:10.1093/ajcp/84.1.24 · Cited by 177
Cited by
Vogl, T., Tenbrock, K., Ludwig, S., Leukert, N., Ehrhardt, C., van Zoelen, M. A. D., Nacken, W., Foell, D., van der Poll, T., Sorg, C., et al. (2007) · Nature Medicine · doi:10.1038/nm1638 · Cited by 1,418
Self-citationEhrchen, J. M., Sunderkötter, C., Foell, D., Vogl, T., & Roth, J. (2009) · Journal of Leukocyte Biology · doi:10.1189/jlb.1008647 · Cited by 846
Self-citationIon Formation in MALDI: The Cluster Ionization Mechanism
Karas, M., & Krüger, R. (2003) · Chemical Reviews · doi:10.1021/cr010376a · Cited by 651
Calcium-dependent and -independent interactions of the S100 protein family
Santamaria-Kisiel, L., Rintala-Dempsey, A. C., & Shaw, G. S. (2006) · Biochemical Journal · doi:10.1042/bj20060195 · Cited by 581
Calprotectin: from biomarker to biological function
Jukic, A., Bakiri, L., Wagner, E. F., Tilg, H., & Adolph, T. E. (2021) · Gut · doi:10.1136/gutjnl-2021-324855 · Cited by 500
Metadata
- Authors
- Vog, T., Roth, J., Sorg, C., Hillenkamp, F., & Strupat, K.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-11-01
- Volume
- 10
- Issue
- 11
- Pages
- 1124-1130
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W1983366080
- Cited by
- 133
- References
- 2
- FWCI
- 1.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calcium-induced noncovalently linked tetramers of MRP8 and MRP14 detected by ultraviolet matrix-assisted laser desorption/ionization mass spectrometry. https://app.cochat.ai/papers/10.1016/s1044-0305(99)00085-9
- The paper
- Vog, T., Roth, J., Sorg, C., Hillenkamp, F., & Strupat, K. (1999). Calcium-induced noncovalently linked tetramers of MRP8 and MRP14 detected by ultraviolet matrix-assisted laser desorption/ionization mass spectrometry. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/s1044-0305(99)00085-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.