Cited by 7,213Muscle activation and electromyography studiesPeripheral Nerve DisordersMuscle Physiology and Disorders

Development of recommendations for SEMG sensors and sensor placement procedures

Hermens, Hermie J, Freriks, Bart, Disselhorst-Klug, Catherine, Rau, Günter·2000·Journal of Electromyography and Kinesiology

Abstract

The knowledge of surface electromyography (SEMG) and the number of applications have increased considerably during the past ten years. However, most methodological developments have taken place locally, resulting in different methodologies among the different groups of users.A specific objective of the European concerted action SENIAM (surface EMG for a non-invasive assessment of muscles) was, besides creating more collaboration among the various European groups, to develop recommendations on sensors, sensor placement, signal processing and modeling. This paper will present the process and the results of the development of the recommendations for the SEMG sensors and sensor placement procedures. Execution of the SENIAM sensor tasks, in the period 1996-1999, has been handled in a number of partly parallel and partly sequential activities. A literature scan was carried out on the use of sensors and sensor placement procedures in European laboratories. In total, 144 peer-reviewed papers were scanned on the applied SEMG sensor properties and sensor placement procedures. This showed a large variability of methodology as well as a rather insufficient description. A special workshop provided an overview on the scientific and clinical knowledge of the effects of sensor properties and sensor placement procedures on the SEMG characteristics. Based on the inventory, the results of the topical workshop and generally accepted state-of-the-art knowledge, a first proposal for sensors and sensor placement procedures was defined. Besides containing a general procedure and recommendations for sensor placement, this was worked out in detail for 27 different muscles. This proposal was evaluated in several European laboratories with respect to technical and practical aspects and also sent to all members of the SENIAM club (>100 members) together with a questionnaire to obtain their comments. Based on this evaluation the final recommendations of SENIAM were made and published (SENIAM 8: European recommendations for surface electromyography, 1999), both as a booklet and as a CD-ROM. In this way a common body of knowledge has been created on SEMG sensors and sensor placement properties as well as practical guidelines for the proper use of SEMG.

Integrity signals

Registry

Crossref · 10.1016/s1050-6411(00)00027-4

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • SEMG electrodes were placed according to the recommendations of the SENIAM project.

    “The skin was shaved and cleaned with alcohol according to the recommendations of the Surface Electromyography for the Non-Invasive Assessment of Muscles (SENIAM) project (Hermens et al., 2000).”

    From Standardization of the Jendrassik maneuver in Achilles tendon tap reflex (2018) · cites this paper as Hermens et al., 2000

The citation lists haven’t been fetched yet

References 11 · Cited by 7,213

Authors
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G.
Affiliations
Roessingh Research and Development (NL)
Corresponding author
Hermens, Hermie J
Venue
Journal of Electromyography and Kinesiology
Publisher
Elsevier BV
Published
2000-10
Volume
10
Issue
5
Pages
361-374
ISSN
1050-6411 (ISSN-L)
OpenAlex
W2000439420
Cited by
7,213
References
11
Citations by year
2026: 659 · 2025: 652 · 2024: 606 · 2023: 563 · 2022: 516 · 2021: 564 · 2020: 538 · 2019: 414 · 2018: 393 · 2017: 368 · 2016: 334 · 2015: 311 · 2014: 276 · 2013: 249 · 2012: 183
FWCI
10.74
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Electromyography and Kinesiology (publishedVersion)
  • PubMed (publishedVersion)
  • University of Twente Research Information (acceptedVersion)
  • RWTH Publications (RWTH Aachen) (submittedVersion)
  • University of Twente Research Information (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Peripheral Nerve Disorders
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Muscle Physiology and Disorders
Keywords
surface electromyography, sensor placement, sensor characteristics
MeSH terms
Electrodes, Electromyography, Humans, Muscle Contraction, Practice Guidelines as Topic, Muscle, Skeletal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review