Crosstalk in surface electromyography of the proximal forearm during gripping tasks
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Use of Surface Electromyography in Biomechanics
De Luca, C. J. (1997) · Journal of Applied Biomechanics · doi:10.1123/jab.13.2.135 · Cited by 3,268 · cited 1×
“Using the cross-correlation function with surface EMG has also been criticized due to the potential confounds of tissue filtering and motor unit synchronization between coactivated muscles [19].”
BackgroundNew Developments in Electromyography and Clinical Neurophysiology.
(1974) · Archives of Neurology · doi:10.1001/archneur.1974.00490320078016 · Cited by 1,622
Anatomical Guide for the Electromyographer: The Limbs and Trunk
Perotto, A., & Delagi, E. F. (1980) · Cited by 621
The contractile properties of human motor units during voluntary isometric contractions
Milner‐Brown, H. S., Stein, R. B., & Yemm, R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010087 · Cited by 476 · cited 1×
“Although motor unit synchronization has been examined with surface EMG using cross-correlation [9,12] and other techniques [22], its effectiveness is debatable [23,24].”
BackgroundCrosstalk in surface electromyography: Theoretical and practical estimates
Winter, D. A., Fuglevand, A. J., & Archer, S. E. (1994) · Journal of Electromyography and Kinesiology · doi:10.1016/1050-6411(94)90023-x · Cited by 390 · cited 10×
“Several methods have been used to quantify the amount of common signal (or crosstalk) present between neighbouring muscles, the most common being the cross-correlation function (CCF) [8] [9] [10] [11] [12] [13].”
BackgroundMethodResultInfluentialVoluntary control of motor units in human antagonist muscles: coactivation and reciprocal activation
De Luca, C. J., & Mambrito, B. (1987) · Journal of Neurophysiology · doi:10.1152/jn.1987.58.3.525 · Cited by 367 · cited 1×
“This likely reflects minimal crosstalk between the flexor and extensor muscle compartments and an inability of surface EMG to reflect motor unit firing rates, which may be moderately correlated between antagonists during isometric tasks [21].”
BackgroundSurface myoelectric signal cross-talk among muscles of the leg
De Luca, C. J., & Merletti, R. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90169-1 · Cited by 339 · cited 1×
“De Luca and Merletti (1988) [15] electrically stimulated the tibialis anterior and found that up to 16.”
BackgroundAnatomical Guide for the Electromyographer: The Limbs and Trunk
Hennessey, W. J. (1995) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-199505000-00020 · Cited by 272
Estimating the strength of common input to human motoneurons from the cross‐correlogram.
Nordstrom, M. A., Fuglevand, A. J., & Enoka, R. M. (1992) · The Journal of Physiology · doi:10.1113/jphysiol.1992.sp019244 · Cited by 259 · cited 1×
“With fine wire EMG, analyses examining synchronization and common input to single motor units have included the cumulative sum procedure (CUSUM) followed by various synchronization indices [20].”
MethodHow Forearm Position Affects Grip Strength
Richards, L. G., Olson, B., & Palmiter-Thomas, P. (1996) · The American Journal of Occupational Therapy · doi:10.5014/ajot.50.2.133 · Cited by 232 · cited 2×
“The reduced maximal force from neutral to pronation during grasp, and the similar force levels in all three forearm postures during maximal pinch trials are comparable to previous investigations of grasp [25,26,27] and pinch [28].”
ResultSurface and wire EMG crosstalk in neighbouring muscles
Solomonow, M., Baratta, R., Bernardi, M., Zhou, B., Lu, Y., Zhu, M., & Acierno, S. (1994) · Journal of Electromyography and Kinesiology · doi:10.1016/1050-6411(94)90014-0 · Cited by 215 · cited 3×
“Comparisons between surface and intramuscular recordings have been made in humans [18], however, determining crosstalk using EMG amplitude measures may leave room for misinterpretation, except for truly isolated specimens [16].”
BackgroundMaier, M. A., & Hepp-Reymond, M.-C. (1995) · Experimental Brain Research · doi:10.1007/bf00241970 · Cited by 182 · cited 3×
“Several methods have been used to quantify the amount of common signal (or crosstalk) present between neighbouring muscles, the most common being the cross-correlation function (CCF) [8,9,10,11,12,13].”
BackgroundMethodCommon Drive in Motor Units of a Synergistic Muscle Pair
De Luca, C. J., & Erim, Z. (2002) · Journal of Neurophysiology · doi:10.1152/jn.00793.2001 · Cited by 173 · cited 2×
“Several methods have been used to quantify the amount of common signal (or crosstalk) present between neighbouring muscles, the most common being the cross-correlation function (CCF) [8,9,10,11,12,13].”
MethodAnatomical Guide for the Electromyographer: The Limbs and Trunk, 3rd Ed.
Katirji, B. (1994) · Neurology · doi:10.1212/wnl.44.11.2221 · Cited by 120
The effects of skinfold thickness on the selectivity of surface EMG
la Barrera, E. J. D., & Milner, T. E. (1994) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(94)90071-x · Cited by 80 · cited 1×
“Greater skinfold thickness has also been shown to increase cross-correlations in humans, effectively decreasing selectivity of the electrode [17].”
BackgroundAuto-and cross-correlation analysis of the electrical activity of muscles
Person, R. S., & Ln, M. (1964) · Medical & Biological Engineering & Computing · doi:10.1007/bf02484214 · Cited by 73
Signal processing and linear systems for the movement sciences
Winter, D. A., & Patla, A. E. (1997) · Medical Entomology and Zoology · Cited by 64
Cross-correlation and cross-talk in surface electromyography.
Jw, M., & Hj, A. (1985) · PubMed · Cited by 59
Limitations of the surface electromyography technique for estimating motor unit synchronization
Yue, G. H., Fuglevand, A. J., Nordstrom, M. A., & Enoka, R. M. (1995) · Biological Cybernetics · doi:10.1007/bf00201424 · Cited by 53 · cited 1×
“Although motor unit synchronization has been examined with surface EMG using cross-correlation [9,12] and other techniques [22], its effectiveness is debatable [23,24].”
BackgroundTask dependence of muscle synchronization in human hand muscles
Huesler, E. J., Mc, H.-R., & Dietz, V. H. (1998) · Neuroreport · doi:10.1097/00001756-199807130-00003 · Cited by 46 · cited 4×
“Several methods have been used to quantify the amount of common signal (or crosstalk) present between neighbouring muscles, the most common being the cross-correlation function (CCF) [8,9,10,11,12,13].”
BackgroundMethodResultInfluentialSemmler, J. G., & Nordstrom, M. A. (1999) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00069-2 · Cited by 46 · cited 1×
“Although motor unit synchronization has been examined with surface EMG using cross-correlation [9,12] and other techniques [22], its effectiveness is debatable [23,24].”
BackgroundReproducibility Problems when Using Wire Electrodes in Electromyographic Kinesiology
Jonsson, B. G., & Komi, P. V. (2015) · KARGER eBooks · doi:10.1159/000394058 · Cited by 21 · cited 1×
“The smaller pick-up volume and greater specificity of fine wire electrodes has been offered as a solution for crosstalk issues, however, these electrodes have been shown to shift within the muscle and alter the activity recorded [4].”
Background
Cited by
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573
“Alternatively, the presence of crosstalk has been estimated by calculating the cross-correlation coefficient between the signals detected from two muscles (1, 59, 61, 83).”
Neural Adaptations to Resistive Exercise: Mechanisms and Recommendations for Training Practices
Gabriel, D. A., Kamen, G., & Frost, G. (2006) · Sports Medicine · doi:10.2165/00007256-200636020-00004 · Cited by 794
The effects of posture on forearm muscle loading during gripping
Mogk, J., & Keir, P. (2003) · Ergonomics · doi:10.1080/0014013031000107595 · Cited by 224
“Pronation of the forearm has also been shown to reduce grip force, but the effects of supination are less clear (Halpern and Fernandez 1996, Richards et al. 1996, Claudon 1998, De Smet et al. 1998, Mogk and Keir 2003).”
BackgroundMethodSelf-citationGluteus medius muscle activation patterns as a predictor of low back pain during standing
Nelson-Wong, E., Gregory, D. E., Winter, D. A., & Callaghan, J. P. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.01.002 · Cited by 207
“, 2005a, b) and muscle activation (Osu et al., 2002; Mogk and Keir, 2003; McDonnell et al., 2005) data previously.”
BackgroundMethodNelson-Wong, E., & Callaghan, J. P. (2010) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2009.04.009 · Cited by 182
Metadata
- Authors
- Mogk, J. P. M., & Keir, P. J.
- Venue
- Journal of Electromyography and Kinesiology
- Publisher
- Elsevier BV
- Published
- 2003-02
- Volume
- 13
- Issue
- 1
- Pages
- 63-71
- ISSN
- 1050-6411 (ISSN-L)
- OpenAlex
- W2112943365
- Cited by
- 188
- References
- 22
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.