The DOI matches its Crossref record.
Mycotic Aneurysms of the Thoracic Aorta: Repair with Use of Endovascular Stent-Grafts
Open accessAbstract
PURPOSE: Standard therapy of mycotic aneurysms in the descending aorta consists of thoracotomy and in situ graft placement or extraanatomic bypass. The alternative use of endovascular stent-grafts was evaluated for management of infected aneurysms of the thoracic aorta. MATERIALS AND METHODS: In a retrospective analysis during a 5-year period, 112 patients underwent stent-graft placement for thoracic aortic aneurysms. Three patients (mean age, 68.6; range, 64-70 years) had mycotic thoracic aneurysms. Stent-grafts were constructed from Z stents covered with polyester fabric and were delivered remotely through a catheter under fluoroscopic guidance. RESULTS: Complete thrombosis of the mycotic aneurysms was achieved in all patients. One patient required a second separate stent-graft placement procedure because of migration of the initial device; the second patient underwent surgical repair of a ruptured mycotic abdominal aortic aneurysm followed immediately by stent-graft placement for a chronic mycotic thoracic aneurysm; a third patient underwent repair of two infected false aneurysms secondary to complete rupture of a surgical interposition graft. There were no complications of persistent bacteremia despite placement of the stent-graft device at the site of primary infection, reinfection, delayed rupture, paraplegia, distal emboli, or surgical conversion. One patient died of cardiac arrest at 25 months; there were no perioperative deaths (< or = 30 days). The remaining two patients were alive and well at median follow-up of 24 months (range, 4-25 months). CONCLUSION: Endovascular stent-grafts combined with antibiotic therapy may be an alternative to conventional thoracotomy in managing mycotic aneurysms of the descending thoracic aorta.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Svensson, L. G., Kouchoukos, N. T., Miller, D. C., Bavaria, J. E., Coselli, J. S., Curi, M. A., Eggebrecht, H., Elefteriades, J. A., Erbel, R., Gleason, T. G., et al. (2008) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2007.10.099 · Cited by 860
Self-citationWilson, W. R., Bower, T. C., Creager, M. A., Amin-Hanjani, S., O’Gara, P. T., Lockhart, P. B., Darouiche, R. O., Ramlawi, B., Derdeyn, C. P., Bolger, A. F., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000457 · Cited by 572
Gornik, H. L., & Creager, M. A. (2008) · Circulation · doi:10.1161/circulationaha.107.760686 · Cited by 505
Outcome after endovascular stent graft treatment for mycotic aortic aneurysm: A systematic review
Kan, C.-D., Lee, H.-L., & Yang, Y.-J. (2007) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2007.07.025 · Cited by 386
Infectious Thoracic Aortitis: A Literature Review
Lopes, R. J., Almeida, J., Dias, P. J., Pinho, P., & Maciel, M. J. (2009) · Clinical Cardiology · doi:10.1002/clc.20578 · Cited by 196
Metadata
- Authors
- Semba, C. P., Sakai, T., Slonim, S. M., Razavi, M. K., Kee, S. T., Jorgensen, M. J., Hagberg, R. C., Lee, G. K., Mitchell, R. S., Craig Miller, D., & Dake, M. D.
- Venue
- Journal of Vascular and Interventional Radiology
- Publisher
- Elsevier BV
- Published
- 1998-01
- Volume
- 9
- Issue
- 1
- Pages
- 33-40
- ISSN
- 1051-0443 (ISSN-L)
- OpenAlex
- W1966471173
- Cited by
- 251
- References
- 0
- FWCI
- 7.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mycotic Aneurysms of the Thoracic Aorta: Repair with Use of Endovascular Stent-Grafts. https://app.cochat.ai/papers/10.1016/s1051-0443(98)70479-8
- The paper
- Semba, C. P., Sakai, T., Slonim, S. M., Razavi, M. K., Kee, S. T., Jorgensen, M. J., Hagberg, R. C., Lee, G. K., Mitchell, R. S., Craig Miller, D., & Dake, M. D. (1998). Mycotic Aneurysms of the Thoracic Aorta: Repair with Use of Endovascular Stent-Grafts. Journal of Vascular and Interventional Radiology. https://doi.org/10.1016/s1051-0443(98)70479-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.