The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: A prospective criterion standard study in patients after cardiac surgery
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
The Effectiveness of Right Heart Catheterization in the Initial Care of Critically III Patients
Connors, A. F. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540110043030 · Cited by 2,210
Errors in the measurement of cardiac output by thermodilution
Nishikawa, T., & Dohi, S. (1993) · Canadian Journal of Anaesthesia · doi:10.1007/bf03011312 · Cited by 302
Thermodilution cardiac output: A critical analysis and review of the literature
Levett, J. M., & Replogle, R. L. (1979) · Journal of Surgical Research · doi:10.1016/0022-4804(79)90159-8 · Cited by 241
Noninvasive Monitoring of Cardiac Output in Critically Ill Patients Using Transesophageal Doppler
Valtier, B., Cholley, B., Belot, J.-P., Coussaye, J.-E. D. L., Matéo, J., & Payen, D. M. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.1.9707031 · Cited by 235
Continuous cardiac output monitoring by pulse contour during cardiac surgery
Jansen, J. R. C., Wesseling, K. H., Settels, J. J., & Schreuder, J. J. (1990) · European Heart Journal · doi:10.1093/eurheartj/11.suppl_i.26 · Cited by 191
Böttiger, B. W., Rauch, H., Bohrer, H., Motsch, J., Soder, M., Fleischer, F., & Martin, E. (1995) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(05)80095-3 · Cited by 77
Analysis of the accuracy of continuous thermodilution cardiac output measurement
Jacquet, L., Hanique, G., Glorieux, D., Matte, P., & Goenen, M. (1996) · Intensive Care Medicine · doi:10.1007/bf01699240 · Cited by 76
Intraoperative cardiac output monitoring: Comparison of impedance cardiography and thermodilution
Perrino, A. C., Lippman, A., Ariyan, C., O'CONNOR, T., & Luther, M. A. (1994) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/1053-0770(94)90007-8 · Cited by 38
Metadata
- Authors
- Zöllner, C., Haller, M., Weis, M., Mörstedt, K., Lamm, P., Kilger, E., & Goetz, A. E.
- Venue
- Journal of Cardiothoracic and Vascular Anesthesia
- Publisher
- Elsevier BV
- Published
- 2000-04
- Volume
- 14
- Issue
- 2
- Pages
- 125-129
- ISSN
- 1053-0770 (ISSN-L)
- OpenAlex
- W2157385670
- Cited by
- 375
- References
- 9
- FWCI
- 91.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: A prospective criterion standard study in patients after cardiac surgery. https://app.cochat.ai/papers/10.1016/s1053-0770(00)90003-x
- The paper
- Zöllner, C., Haller, M., Weis, M., Mörstedt, K., Lamm, P., Kilger, E., & Goetz, A. E. (2000). Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: A prospective criterion standard study in patients after cardiac surgery. Journal of Cardiothoracic and Vascular Anesthesia. https://doi.org/10.1016/s1053-0770(00)90003-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.