The DOI matches its Crossref record.
Differences in patellofemoral joint cartilage material properties and their significance to the etiology of cartilage surface fibrillation
Open accessAbstract
OBJECTIVE: To determine if differences in biomechanical properties and biochemical composition exist between human patellar articular cartilage and the opposing femoral articular cartilage. DESIGN: The biomechanical properties and biochemical composition of the articular cartilage of 17 knees from 13 donors were determined for four sites on the patella and three sites on the femur representing regions of contact at 30 degrees and 90 degrees of flexion. The material properties were determined by biphasic indentation testing, yielding the compressive aggregate modulus, HA, permeability, k, and Poisson's ratio, vs. The thickness of the cartilage at the indentation site, h, was also measured using a needle probe. Full-thickness samples of cartilage adjacent to each indentation site were used for wet weight, sulfated glycosaminoglycan content and hydroxyproline content determinations. RESULTS: The patellar cartilage was found to have a lower compressive aggregate modulus by 30% (P < 0.001), higher permeability to fluid flow by 66% (P < 0.001) and greater thickness by 23% (P = 0.017) than that of the opposing femoral cartilage. The Poisson's ratios for both surfaces were found to be nearly zero. The water content of the patella was higher by 5% (P = 0.031) and the proteoglycan content lower by 19% (P = 0.030) than that of the femur. However, no differences were found between the collagen contents of the cartilages. CONCLUSIONS: Significant differences were found between the intrinsic material properties of the patellar cartilage and those of the femoral-trochlear cartilage. This variability of cartilage material properties with the patellofemoral joint may help explain why patellar cartilage has been frequently observed clinically to exhibit earlier and more severe fibrillation changes than the opposing femoral cartilage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mechano-Electrochemical Properties Of Articular Cartilage: Their Inhomogeneities and Anisotropies
Mow, V. C., & Guo, X. E. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.110701.120309 · Cited by 478
Self-citationEckstein, F., Cicuttini, F., Raynauld, J.-P., Waterton, J. C., & Peterfy, C. (2006) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2006.02.026 · Cited by 418
The Influence of Tibial and Femoral Rotation on Patellofemoral Contact Area and Pressure
Lee, T. Q., Morris, G., & Csintalan, R. P. (2003) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2003.33.11.686 · Cited by 375
Gellan gum: A new biomaterial for cartilage tissue engineering applications
Oliveira, J. T., Martins, L., Picciochi, R., Malafaya, P. B., Sousa, R. A., Neves, N. M., Mano, J. F., & Reis, R. L. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32574 · Cited by 370
Detection of changes in cartilage water content using MRI T2-mapping
Liess, C., Lüsse, S., Karger, N., Heller, M., & Glüer, C.-C. (2002) · Osteoarthritis and Cartilage · doi:10.1053/joca.2002.0847 · Cited by 366
Metadata
- Authors
- Froimson, M. I., Ratcliffe, A., Gardner, T. R., & Mow, V. C.
- Venue
- Osteoarthritis and Cartilage
- Publisher
- Elsevier BV
- Published
- 1997-11
- Volume
- 5
- Issue
- 6
- Pages
- 377-386
- ISSN
- 1063-4584 (ISSN-L)
- OpenAlex
- W2067244632
- Cited by
- 163
- References
- 0
- FWCI
- 1.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Differences in patellofemoral joint cartilage material properties and their significance to the etiology of cartilage surface fibrillation. https://app.cochat.ai/papers/10.1016/s1063-4584(97)80042-8
- The paper
- Froimson, M. I., Ratcliffe, A., Gardner, T. R., & Mow, V. C. (1997). Differences in patellofemoral joint cartilage material properties and their significance to the etiology of cartilage surface fibrillation. Osteoarthritis and Cartilage. https://doi.org/10.1016/s1063-4584(97)80042-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.