CoChat

Quantification of SPECT myocardial perfusion images: Methodology and validation of the Yale-CQ method

Open access
Liu, Yi-Hwa, Sinusas, Albert J, DeMan, Paul, Zaret, Barry L, Wackers, Frans J.Th · 1999 · Journal of Nuclear Cardiology
Cited by 76

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Quantification of single photon emission computed tomography (SPECT) images is important for reproducible and accurate image interpretation. In addition, SPECT quantification provides important prognostic information. The purpose of this study was to validate the Yale circumferential quantification (Yale-CQ) method in phantom studies. METHODS: Myocardial perfusion defects of varying extent and severities were simulated in a cardiac phantom with fillable defect inserts. Forty-five different phantom configurations simulated 45 different myocardial perfusion defect sizes, ranging from 1.6% to 32% of the cardiac phantom volume. Automatic processing was compared with manual processing in the phantom SPECT studies. RESULTS: The automatic Yale-CQ algorithm performed well in all phantom studies. Compared with manual processing, the mean absolute error for automatically determined center of short axis slices was 0.27 pixel in the x direction, 0.45 pixel in the y direction, and 0.15 pixel in radius. Quantification of phantom defects with the Yale-CQ method correlated well with actual defect sizes (R = 0.99), but there was a systematic underestimation (mean error = -7.9%). With derived correction factors the overall correlation between 45 phantom defects and actual defect sizes was excellent, and the estimation error was significantly improved (R = 0.98, mean error = -0.82% for manual method and -0.95% for automatic method). CONCLUSION: The automatic processing algorithm performs well for the phantom studies. Myocardial perfusion abnormalities can be quantified accurately by use of the Yale-CQ method. Quantified SPECT defect size can be expressed as a percentage of the left ventricle.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s1071-3581(99)90080-6

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 76

Metadata

Authors
Liu, Y.-H., Sinusas, A. J., DeMan, P., Zaret, B. L., & Wackers, F. J. T.
Venue
Journal of Nuclear Cardiology
Publisher
Elsevier BV
Published
1999-03
Volume
6
Issue
2
Pages
190-203
ISSN
1071-3581 (ISSN-L)
OpenAlex
W2037625227
Cited by
76
References
1
FWCI
3.04
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantification of SPECT myocardial perfusion images: Methodology and validation of the Yale-CQ method. https://app.cochat.ai/papers/10.1016/s1071-3581(99)90080-6
The paper
Liu, Y.-H., Sinusas, A. J., DeMan, P., Zaret, B. L., & Wackers, F. J. T. (1999). Quantification of SPECT myocardial perfusion images: Methodology and validation of the Yale-CQ method. Journal of Nuclear Cardiology. https://doi.org/10.1016/s1071-3581(99)90080-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.