Three Spectra of Laparoscopic Entry Access Injuries

Chandler, James G, Corson, Stephen L, Way, Lawrence W·2001·Journal of the American College of Surgeons

Abstract

BACKGROUND: Procedure-based surveys oflaparoscopic entry access injuries show a reassuringly low incidence, varying from 5 per 10,000 to 3 per 1,000, and, consequently, can provide only limited specific injury data. The current study uses existing injury-based reporting systems to access a uniquely large number of entry injuries to define the nature and outcomes of such events. STUDY DESIGN: Claims arising from US and non-US entry access injuries, between 1980 and 1999, reported to the Physicians Insurers Association of America by their member and affiliate companies and entry-injury medical device reports to the US FDA, from 1995 through October 1997, were analyzed to determine operative procedures, physician specialties, entry devices, and techniques associated with specific injuries. Individual injuries were analyzed for their relative incidence and potential to cause disability and death. RESULTS: Five hundred ninety-four structures or organs were injured in 506 patients, resulting in 65 deaths (13%). General surgical procedures made up at least 67% of combined medical device reports and US Physicians Insurers Association of America cases, and gynecologic procedures accounted for 63% of non-US claims. Bowel and retroperitoneal vascular injuries comprised 76% of all injuries incurred in the process of establishing a primary port. Nearly 50% of both small and large bowel injuries were unrecognized for 24 hours or longer. Delayed recognition, along with age greater than 59 years and major visceral vascular injuries, were each independent significant predictors of death. CONCLUSIONS: No entry technique or device is absolutely safe. Avoidance of entry injuries depends on patient-specific anatomic orientation and control of entry axial force. Certain entry devices can be facilitating in controlling axial force. Overall, this large aggregate of entry access injuries shows them to be more serious and, along with other data, implies that they might be more common than reported in procedure-based studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s1072-7515(01)00820-1

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 194

Metadata

Authors
Chandler, J. G., Corson, S. L., & Way, L. W.
Venue
Journal of the American College of Surgeons
Published
2001-04
Volume
192
Issue
4
Pages
478-490
ISSN
1072-7515 (ISSN-L)
OpenAlex
W2112133336
Cited by
194
References
1
FWCI
6.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Three Spectra of Laparoscopic Entry Access Injuries. https://app.cochat.ai/papers/10.1016/s1072-7515(01)00820-1
The paper
Chandler, J. G., Corson, S. L., & Way, L. W. (2001). Three Spectra of Laparoscopic Entry Access Injuries. Journal of the American College of Surgeons. https://doi.org/10.1016/s1072-7515(01)00820-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.