Structure determination through Z-contrast microscopy
The DOI matches its Crossref record; 73 of the 73 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“High-angle annular dark-field STEM imaging (or Z-contrast imaging) that avoids dynamic diffraction as seen in electron diffraction and high-resolution TEM imaging modes”
From Z-contrast imaging and ab initio study on "d" superstructure in sedimentary dolomite (2014) · cites this paper as Pennycook, 2002
Citations
Cites
Orientation Dependence of Grain-Boundary Critical Currents inYBa2Cu3O7−δBicrystals
Dimos, D., Chaudhari, P., Mannhart, J., & LeGoues, F. K. (1988) · Physical Review Letters · doi:10.1103/physrevlett.61.219 · Cited by 1,385 · cited 1×
“It has been known from soon after their discovery that even a single grain boundary can reduce the critical current by up to four orders of magnitude (Dimos et al., 1990; Dimos et al., 1988; Ivanov et al., 1991).”
BackgroundSuperconducting transport properties of grain boundaries inYBa2Cu3O7bicrystals
Dimos, D., Chaudhari, P., & Mannhart, J. (1990) · Physical Review B · doi:10.1103/physrevb.41.4038 · Cited by 1,308 · cited 1×
“It has been known from soon after their discovery that even a single grain boundary can reduce the critical current by up to four orders of magnitude (Dimos et al., 1990; Dimos et al., 1988; Ivanov et al., 1991).”
BackgroundElectron microscopy image enhanced
Haider, M., Uhlemann, S., Schwan, E., Rose, H., Kabius, B., & Urban, K. (1998) · Nature · doi:10.1038/33823 · Cited by 1,057 · cited 1×
“Working schemes have recently become feasible due largely to increased computer power that allows autotuning of all aberrations up to third order (Dellby et al., 2001; Haider et al., 1998a; Haider et al., 1998b; Krivanek et al., 1999).”
BackgroundThe electronic structure at the atomic scale of ultrathin gate oxides
Muller, D. A., Sorsch, T., Moccio, S., Baumann, F. H., Evans-Lutterodt, K., & Timp, G. (1999) · Nature · doi:10.1038/21602 · Cited by 976 · cited 2×
“This is a timely advantage as technology pushes to ever thinner gate dielectrics and " the end of the roadmap " approaches (Muller et al., 1999).”
BackgroundHigh-resolution Z-contrast imaging of crystals
Pennycook, S. J., & Jesson, D. E. (1991) · Ultramicroscopy · doi:10.1016/0304-3991(91)90004-p · Cited by 976 · cited 1×
“This is a significantly stronger filtering effect than found in the original Bloch wave analysis (Pennycook and Jesson, 1990; Pennycook and Jesson, 1991; Pennycook and Jesson, 1992), where it was assumed that the detected intensity would be proportional to the intensity at the atom sites.”
BackgroundSelf-citationKrivanek, O. L., Dellby, N., & Lupini, A. R. (1999) · Ultramicroscopy · doi:10.1016/s0304-3991(99)00013-3 · Cited by 719 · cited 1×
“Working schemes have recently become feasible due largely to increased computer power that allows autotuning of all aberrations up to third order (Dellby et al., 2001; Haider et al., 1998a; Haider et al., 1998b; Krivanek et al., 1999).”
BackgroundHigh-resolution incoherent imaging of crystals
Pennycook, S. J., & Jesson, D. E. (1990) · Physical Review Letters · doi:10.1103/physrevlett.64.938 · Cited by 688 · cited 1×
“This is a significantly stronger filtering effect than found in the original Bloch wave analysis (Pennycook and Jesson, 1990; Pennycook and Jesson, 1991; Pennycook and Jesson, 1992), where it was assumed that the detected intensity would be proportional to the intensity at the atom sites.”
BackgroundSelf-citationAtomic-resolution chemical analysis using a scanning transmission electron microscope
Browning, N. D., Chisholm, M. F., & Pennycook, S. J. (1993) · Nature · doi:10.1038/366143a0 · Cited by 536
Self-citationIncoherent imaging using dynamically scattered coherent electrons
Nellist, P. D., & Pennycook, S. J. (1999) · Ultramicroscopy · doi:10.1016/s0304-3991(99)00017-0 · Cited by 495 · cited 2×
“Taking the intensity and Fourier transforming with respect to K f a transverse wave vector in the detector plane, and with respect to probe coordinate R 0 gives the component of the image intensity at a spatial frequency ρ (Nellist and Pennycook, 1999).”
MethodSelf-citationA spherical-aberration-corrected 200kV transmission electron microscope
Haider, M., Rose, H., Uhlemann, S., Schwan, E., Kabius, B., & Urban, K. (1998) · Ultramicroscopy · doi:10.1016/s0304-3991(98)00048-5 · Cited by 426 · cited 1×
“Working schemes have recently become feasible due largely to increased computer power that allows autotuning of all aberrations up to third order (Dellby et al., 2001; Haider et al., 1998a; Haider et al., 1998b; Krivanek et al., 1999).”
Background
Research works printed but not linked: 1
- Rose, 1976, Image formation by inelastically scattered electrons in electron microscopy, Optik, 45, 187
Cited by
Single-Atom Catalysts: From Design to Application
Cheng, N., Zhang, L., Doyle-Davis, K., & Sun, X. (2019) · Electrochemical Energy Reviews · doi:10.1007/s41918-019-00050-6 · Cited by 634
Observation of rare-earth segregation in silicon nitride ceramics at subnanometre dimensions
Shibata, N., Pennycook, S. J., Gosnell, T. R., Painter, G. S., Shelton, W. A., & Becher, P. (2004) · Nature · doi:10.1038/nature02410 · Cited by 326
Self-citationSteurer, W. (2004) · Zeitschrift für Kristallographie - Crystalline Materials · doi:10.1524/zkri.219.7.391.35643 · Cited by 322
“Therefore, this method is also called ‘Z-contrast method’ (see Saitoh, Tsuda, Tanaka, Tsai, 2000, and references therein; Pennycook, 2002).”
Scanning Transmission Electron Microscopy
Nellist, P. D. (2008) · Science of Microscopy · doi:10.1007/978-0-387-49762-4_2 · Cited by 217
“The use of ADF imaging for structure determination is now widespread (Pennycook, 2002).”
MATERIALS CHARACTERIZATION IN THE ABERRATION-CORRECTED SCANNING TRANSMISSION ELECTRON MICROSCOPE
Varela, M., Lupini, A. R., Benthem, K. V., Borisevich, A. Y., Chisholm, M. F., Shibata, N., Abe, E., & Pennycook, S. J. (2005) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.35.102103.090513 · Cited by 211
Self-citation
Metadata
- Authors
- Pennycook, S. J.
- Affiliations
- Oak Ridge National Laboratory (US)
- Corresponding author
- Pennycook, S.J.
- ORCID
- Pennycook, S.J.
- Venue
- Advances in Imaging and Electron Physics
- Publisher
- Elsevier
- Published
- 2002
- Pages
- 173-206
- ISSN
- 1076-5670 (ISSN-L)
- OpenAlex
- W1607277606
- Semantic Scholar
- 68ec06fe9ab748239f2cbb844360f2ecd13f5e24
- Cited by
- 140
- References
- 73
- Citations by year
- 2026: 2 · 2024: 3 · 2023: 2 · 2022: 8 · 2021: 9 · 2020: 6 · 2019: 10 · 2018: 5 · 2017: 15 · 2016: 14 · 2015: 12 · 2014: 11 · 2013: 6 · 2012: 3
- FWCI
- 9.65
- Type
- book chapter
- Language
- en
- Open access
- closed
- Locations
- Advances in imaging and electron physics (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Structural Biology › Advanced Electron Microscopy Techniques and Applications
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Electron and X-Ray Spectroscopy Techniques
- Physical Sciences › Materials Science › General Materials Science › Advanced Materials Characterization Techniques
- Keywords
- Z-contrast imaging, electron energy loss spectroscopy, scanning transmission electron microscopy, structure determination, phase problem, impurity segregation, vacancy segregation, electronic structure, aberration correction, catalysis, structural materials, nanostructured materials
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.