Factors associated with early failure of arteriovenous fistulae for haemodialysis access
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The radiocephalic arteriovenous fistula remains the method of choice for haemodialysis access. In order to assess their suitability for fistula formation, the radial arteries and cephalic veins were examined preoperatively by ultrasound colour flow scanner in conjunction with a pulse-generated run-off system. Intraoperative blood flow was measured after construction of the fistulae. Post-operative follow-up was performed at various intervals to monitor the development of the fistulae. Radial artery and cephalic vein diameter less than 1.6 mm was associated with early fistula failure. The intraoperative fistula blood flow did not correlate with the outcome of the operation probably due to vessel spasm from manipulation. However, blood flow velocities measured non-invasively 1 day after the operation were significantly lower in fistulae that failed early compared with those that were adequate for haemodialysis. Most of the increase in fistula diameter and blood flow occur within the first 2 weeks of surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Practical Statistics for Medical Research.
Walter, S. D., & Altman, D. G. (1992) · Biometrics · doi:10.2307/2532320 · Cited by 11,668
Practical statistics for medical research
King, M. (1992) · Journal of Psychosomatic Research · doi:10.1016/0022-3999(92)90046-5 · Cited by 1,659
McDonald, D. A. (1963) · The American Journal of the Medical Sciences · doi:10.1097/00000441-196301000-00017 · Cited by 1,565
Vascular Access for Hemodialysis Patency Rates and Results of Revision
PALDER, S. B., KIRKMAN, R. L., WHITTEMORE, A. D., HAKIM, R. M., LAZARUS, J. M., & TILNEY, N. L. (1985) · Annals of Surgery · doi:10.1097/00000658-198508000-00015 · Cited by 514
Tordoir, J. H. M., Hoeneveld, H., Eikelboom, B. C., & Kitslaar, P. J. E. H. M. (1990) · European Journal of Vascular Surgery · doi:10.1016/s0950-821x(05)80434-7 · Cited by 57
Cited by
KDOQI Clinical Practice Guideline for Vascular Access: 2019 Update
Lok, C. E., Huber, T. S., Lee, T., Shenoy, S., Yevzlin, A. S., Abreo, K., Allon, M., Asif, A., Astor, B. C., Glickman, M. H., et al. (2020) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2019.12.001 · Cited by 2,590
Recommended standards for reports dealing with arteriovenous hemodialysis accesses
Sidawy, A. N., Gray, R., Besarab, A., Henry, M., Ascher, E., Silva, M., Miller, A., Scher, L., Trerotola, S., Gregory, R. T., et al. (2002) · Journal of Vascular Surgery · doi:10.1067/mva.2002.122025 · Cited by 904
Schmidli, J., Widmer, M. K., Basile, C., de Donato, G., Gallieni, M., Gibbons, C. P., Haage, P., Hamilton, G., Hedin, U., Kamper, L., et al. (2018) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2018.02.001 · Cited by 878
Increasing arteriovenous fistulas in hemodialysis patients: Problems and solutions
Allon, M., & Robbin, M. L. (2002) · Kidney International · doi:10.1046/j.1523-1755.2002.00551.x · Cited by 763
Tordoir, J., Canaud, B., Haage, P., Konner, K., Basci, A., Fouque, D., Kooman, J., Martin-Malo, A., Pedrini, L., Pizzarelli, F., et al. (2007) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfm021 · Cited by 645
Metadata
- Authors
- Wong, V., Ward, R., Taylor, J., Selvakumar, S., How, T. V., & Bakran, A.
- Venue
- European Journal of Vascular and Endovascular Surgery
- Publisher
- Elsevier BV
- Published
- 1996-08
- Volume
- 12
- Issue
- 2
- Pages
- 207-213
- ISSN
- 1078-5884 (ISSN-L)
- OpenAlex
- W2089915351
- Cited by
- 428
- References
- 5
- FWCI
- 4.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.