Improved endothelial cell attachment on ePTFE vascular grafts pretreated with synthetic RGD-containing peptides
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
OBJECTIVES To assess endothelial cell (EC) attachment in seeding of expanded polytetrafluoroethylene (ePTFE) vascular prostheses by application of a new technique of coupling synthetic RGD-containing peptides with the graft surface. DESIGN Prospective, open study. SETTING University Department of Cardiovascular Surgery and Institute of Biochemistry. MATERIALS AND METHODS ePTFE vascular grafts (group 1) uncoated (group 2) coated with fibronectin (group 3) coated with a RGD-containing peptide or (group 4) coated in a similar way to group 3 but without application of a RGD-peptide, were incubated for 30 min with adult human saphenous vein endothelial cells. After seeding, grafts were exposed to shear stress in an artificial flow circuit. EC attachment after seeding and retention after perfusion was assessed by scanning electron microscopy and image analysis. MAIN RESULTS Both EC attachment and retention were significantly increased by coating with fibronectin in comparison to uncoated ePTFE. Graft coating with an RGD-peptide lead to the highest increase in EC attachment (30.6% +/- 2.1%) and retention after shear stress (62.9% +/- 7.5%) compared to fibronectin coated (26.0% +/- 3.3%/45.5% +/- 2.1%), uncoated (14.9% +/- 3.1%/13.9% +/- 7.9%) and similar coated ePTFE grafts without application of a RGD-peptide (10.5% +/- 1.1%/6.6% +/- 1.5%). CONCLUSIONS EC attachment on uncoated ePTFE vascular prostheses is very weak. Our technique of coupling the ePTFE graft surface with cell adhesion promoting RGD-containing synthetic peptides significantly improved this decisive step in endothelial cell seeding of ePTFE grafts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pierschbacher, M. D., & Ruoslahti, E. (1984) · Nature · doi:10.1038/309030a0 · Cited by 3,658
Graf, J., Iwamoto, Y., Sasaki, M., Martin, G. R., Kleinman, H. K., Robey, F. A., & Yamada, Y. (1987) · Cell · doi:10.1016/0092-8674(87)90707-0 · Cited by 671
Pierschbacher, M. D., & Ruoslahti, E. (1987) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)45376-8 · Cited by 649
Humphries, M. J., Akiyama, S. K., Komoriya, A., Olden, K., & Yamada, K. M. (1986) · The Journal of cell biology · doi:10.1083/jcb.103.6.2637 · Cited by 438
Fibronectin: A review of its structure and biological activity
Pearlstein, E., Gold, L. I., & García-Pardo, A. (1980) · Molecular and Cellular Biochemistry · doi:10.1007/bf00220304 · Cited by 382
Zilla, P., Deutsch, M., Meinhart, J., Puschmann, R., Eberl, T., Minar, E., Dudczak, R., Lugmaier, H., Schmidt, P., Noszian, I., et al. (1994) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(94)70083-4 · Cited by 209
Stanley, J. C., Burkel, W. E., Ford, J. W., Vinter, D. W., Kahn, R. H., Whitehouse, W. M., & Graham, L. M. (1982) · PubMed · Cited by 187
Aota, S., Nagai, T., & Yamada, K. M. (1991) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)98498-x · Cited by 179
Lin, H., Sun, W., Mosher, D. F., García‐Echeverría, C., Schaufelberger, K., Lelkes, P. I., & Cooper, S. L. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280307 · Cited by 178
Fibrin glue in surgery: frequent development of inhibitors of bovine thrombin and human factor V
Bänninger, H., Hardegger, T., Tobler, A., Barth, A., Schupbach, P., Reinhart, W., Lammle, B., & Furlan, M. (1993) · British Journal of Haematology · doi:10.1111/j.1365-2141.1993.tb03343.x · Cited by 175
Endothelial cells adhere to the rgd domain and the fibrinogen-like terminal knob of tenascin
Joshi, P., Chung, C.-Y., Aukhil, I., & Erickson, H. P. (1993) · Journal of Cell Science · doi:10.1242/jcs.106.1.389 · Cited by 161
Kaehler, J., Zilla, P., Fasol, R., Deutsch, M., & Kadletz, M. (1989) · Journal of Vascular Surgery · doi:10.1016/0741-5214(89)90469-2 · Cited by 150
Graham, L. M., Burkel, W. E., Ford, J. W., Vinter, D. W., Kahn, R. H., & Stanley, J. C. (1980) · Archives of Surgery · doi:10.1001/archsurg.1980.01380110033005 · Cited by 139
Tashiro, K., Sephel, G. C., Greatorex, D., Sasaki, M., Shirashi, N., Martin, G. R., Kleinman, H. K., & Yamada, Y. (1991) · Journal of Cellular Physiology · doi:10.1002/jcp.1041460316 · Cited by 120
Allen, B. T., Long, J. A., Clark, R. E., Sicard, G. A., Hopkins, K. T., & Welch, M. J. (1984) · Journal of Vascular Surgery · doi:10.1016/0741-5214(84)90201-5 · Cited by 115
Sharefkin, J. B., Latker, C. H., Smith, M., Cruess, D. F., Clagett, P. G., & Rich, N. M. (1982) · PubMed · Cited by 95
Magometschnigg, H. F., Kadletz, M., Vodrazka, M., Dock, W., Grimm, M. F., Grabenwöger, M., Minar, E., Staudacher, M., Fenzl, G., & Wolner, E. (1992) · Journal of Vascular Surgery · doi:10.1016/0741-5214(92)90192-b · Cited by 90
Schneider, P. A., Hanson, S. R., Price, T. M., & Harker, L. A. (1988) · Journal of Vascular Surgery · doi:10.1016/0741-5214(88)90272-8 · Cited by 73
Miyata, T., Conte, M. S., Trudell, L. A., Mason, D. P., Whittemore, A. D., & Birinyi, L. K. (1991) · Journal of Surgical Research · doi:10.1016/0022-4804(91)90029-l · Cited by 70
Comparison of different vascular prostheses and matrices in relation to endothelial seeding
Vohra, R. K., Thomson, G. J. L., Carr, H. M. H., Sharma, H. L., & Walker, M. G. (1991) · British journal of surgery · doi:10.1002/bjs.1800780411 · Cited by 69
Conventional versus high-porosity polytetrafluoroethylene grafts: clinical evaluation.
Kohler, T. R., Stratton, J., Kirkman, T. R., Johansen, K. H., Zierler, B. K., & CLOWES, A. W. (1992) · PubMed · Cited by 67
Budd, J. S., Allen, K. E., Bell, P. R. F., & James, R. F. L. (1990) · Journal of Vascular Surgery · doi:10.1016/0741-5214(90)90100-o · Cited by 56
Vohra, R. K., Thomson, G. J. L., Sharma, H. L., Carr, H. M. H., & Walker, M. G. (1990) · European Journal of Vascular Surgery · doi:10.1016/s0950-821x(05)80036-2 · Cited by 43
Cell Attachment and Motility on Materials Modified by Surface‐active RGD‐containing Peptides
Glass, J. D., Blevitt, J., Dickerson, K., Pierschbacher, M. D., & Craig, W. S. (1994) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1994.tb44372.x · Cited by 37
Fibrin Glue Coating of e-PTFE Prostheses Enhances Seeding of Human Endothelial cells
Schrenk, P., Kobinia, G. S., Brücke, P., Syre, G., & Edtstadler, A. (1987) · The Thoracic and Cardiovascular Surgeon · doi:10.1055/s-2007-1020188 · Cited by 15
Cited by
RGD modified polymers: biomaterials for stimulated cell adhesion and beyond
Hersel, U., Dahmen, C., & Kessler, H. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00343-0 · Cited by 2,582
Biomimetic materials for tissue engineering
Shin, H., Jo, S., & Mikos, A. G. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00339-9 · Cited by 1,612
Biocompatible polymer materials: Role of protein–surface interactions
Chen, H., Yuan, L., Song, W., Wu, Z., & Li, D. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.07.006 · Cited by 706
Techniques for mechanical stimulation of cells in vitro: a review
Brown, T. D. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00177-3 · Cited by 539
Biomaterials for Vascular Tissue Engineering
Ravi, S., & Chaikof, E. L. (2010) · Regenerative Medicine · doi:10.2217/rme.09.77 · Cited by 387
Metadata
- Authors
- Walluscheck, K. P., Steinhoff, G., Kelm, S., & Haverich, A.
- Venue
- European Journal of Vascular and Endovascular Surgery
- Publisher
- Elsevier BV
- Published
- 1996-10
- Volume
- 12
- Issue
- 3
- Pages
- 321-330
- ISSN
- 1078-5884 (ISSN-L)
- OpenAlex
- W2004416466
- Cited by
- 158
- References
- 25
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.