Controlled‐release oxycodone compared with controlled‐release morphine in the treatment of cancer pain: A randomized, double‐blind, parallel‐group study
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Controlled‐release oral formulations of oxycodone and morphine are both suitable analgesics for moderate to severe pain. They were compared in cancer‐pain patients randomized to double‐blind treatment with controlled‐release oxycodone (n = 48) or controlled‐release morphine (n = 52) every 12 h for up to 12 days. Stable analgesia was achieved by 83% of controlled‐release oxycodone and 81% of controlled‐release morphine patients in 2 days (median). Following titration to stable analgesia, pain intensity (0/none to 3/severe) decreased from baseline within each group (p≤ 0.005), from 1.9 (0.1) to 1.3 (0.1), mean (SE), with controlled‐release oxycodone, and from 1.6 (0.1) to 1.0 (0.1) with controlled‐release morphine (no significant between‐group differences). Typical opioid adverse experiences were reported in both groups. Hallucinations were reported only with controlled‐release morphine (n = 2). Visual analog scores (VAS) for ‘itchy’ and ‘scratching’ were lower with controlled‐release oxycodone (p≤ 0.044), as was peak‐to‐trough fluctuation in steady‐state plasma concentration (p = 0.004). The correlation between plasma concentration and dose was stronger (p = 0.026) for oxycodone (0.7) than morphine (0.3). The relationship between pain intensity (VAS) and plasma concentration was more positive for oxycodone (p = 0.046). There was a positive relationship between morphine‐6‐glucuronide concentrations and urea nitrogen and creatinine levels (p = 0.0001). Controlled‐release oxycodone was as effective as controlled‐release morphine in relieving chronic cancer‐related pain, and as easily titrated to the individual's need for pain control. While adverse experiences were similar, controlled‐release oxycodone was associated with less itching and no hallucinations. Controlled‐release oxycodone provides a rational alternative to controlled‐release morphine for the management of moderate to severe cancer‐related pain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goodman and Gilman's the Pharmacological Basis of Therapeutics
Stigelman, W. H., & Pharm, D. (1986) · Military Medicine · doi:10.1093/milmed/151.1.386 · Cited by 6,782
The functional assessment of cancer therapy scale: development and validation of the general measure
Cella, D. F., Tulsky, D. S., Gray, G., Sarafian, B., Linn, E., Bonomi, A., Silberman, M., Yellen, S. B., Winicour, P., & Brannon, J. (1993) · Journal of Clinical Oncology · doi:10.1200/jco.1993.11.3.570 · Cited by 6,020 · cited 1×
“…of the study, using the Functional Assessment of Cancer Therapy-General (FACT-G), a 2%item questionnaire consisting of five subscales measuring different aspects of quality of life: physical, social/family, relationship with physician, emotional, and functional (Cella, 1993; Cella et al., 1993).”
MethodGoodman and Gilman's The Pharmacological Basis of Therapeutics
Hastings, R. C. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540120077042 · Cited by 2,371
Benjamin, S. (1994) · Journal of Psychosomatic Research · doi:10.1016/0022-3999(94)90012-4 · Cited by 1,993
de C. Williams, A. C. (1995) · Journal of Psychosomatic Research · doi:10.1016/0022-3999(95)90016-0 · Cited by 1,470
[Drug addiction and drug abuse].
Feuerlein, W. (1969) · PubMed · Cited by 1,415
Foley, K. M. (1985) · New England Journal of Medicine · doi:10.1056/nejm198507113130205 · Cited by 974
(1992) · Cited by 881
Pöyhiä, R., Seppälä, T. T., Olkkola, K. T., & Kalso, E. A. (1992) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1992.tb04090.x · Cited by 304 · cited 2×
“This is consistent with findings that oxycodone may have less propensity to stimulate histamine liberation (Piiyhia et al., 1992a) than morphine (Flacke et al., 1987).”
BackgroundClinical Pharmacokinetics of Morphine
Glare, P. A., & Walsh, T. D. (1991) · Therapeutic Drug Monitoring · doi:10.1097/00007691-199101000-00001 · Cited by 290
Morphine and oxycodone hydrochloride in the management of cancer pain
Kalso, E., & Vainio, A. (1990) · Clinical Pharmacology and Therapeutics · doi:10.1038/clpt.1990.85 · Cited by 261 · cited 3×
“Oxycodone is an effective analgesic for chronic cancer pain Paper received 12 December 1997, revised 5 June 1998 and (Kalso & Vainio, 1990; Glare & Walsh, 1993; accepted in revised form 3 July 1998.”
BackgroundMethodInhibition by fluoxetine of cytochrome P450 2D6 activity
Otton, S. V., Wu, D., Joffe, R. T., Cheung, S. W., & Sellers, E. M. (1993) · Clinical Pharmacology and Therapeutics · doi:10.1038/clpt.1993.43 · Cited by 257 · cited 2×
“While reports in the literature suggest that the oxycodone metabolite, oxymorphone, has analgesic properties (Kalso et al., 1990; Chen et al., 1991; Otton et al., 1993) its plasma concentration in man is very low.”
BackgroundMu receptor binding of some commonly used opioids and their metabolites
Chen, Z. R., Irvine, R. J., Somogyi, A. A., & Bochner, F. (1991) · Life Sciences · doi:10.1016/0024-3205(91)90150-a · Cited by 255 · cited 2×
“While reports in the literature suggest that the oxycodone metabolite, oxymorphone, has analgesic properties (Kalso et al., 1990; Chen et al., 1991; Otton et al., 1993) its plasma concentration in man is very low.”
BackgroundIndividual variability in the response to different opioids: report of five cases
Galer, B. S., Coyle, N., Pasternak, G. W., & Portenoy, R. K. (1992) · Pain · doi:10.1016/0304-3959(92)90192-e · Cited by 241 · cited 1×
“An alternative opioid agonist, such as CR oxycodone, is needed for some patients because of individual differences in sensitivity to the analgesic or side effects of different opioids (Galer et al., 1992; Lawlor et al., 1997; Derby et al., 1998).”
Abuse potential and pharmacological comparison of tramadol and morphine
Preston, K. L., Jasinski, D. R., & Testa, M. (1991) · Drug and Alcohol Dependence · doi:10.1016/0376-8716(91)90081-9 · Cited by 240 · cited 5×
“Although spontaneous reports of pruritus were similar in both treatment groups in the present study, the SDEQ scores for ‘itchy’ rated by patients and ‘scratching’ rated by observers were statistically significantly lower with CR oxycodone than with CR morphine.”
MethodInfluentialControlled-release oxycodone and morphine in cancer related pain
Heiskanen, T., & Kalso, E. (1997) · Pain · doi:10.1016/s0304-3959(97)00072-9 · Cited by 229 · cited 2×
“A two-period cross-over study, comparing oral CR oxycodone and oral CR morphine in cancer pain found that pain was well controlled with both treatments (Heiskanen & Kalso, 1997).”
BackgroundMethodPharmacokinetic-pharmacodynamic relationships of controlled-release oxycodone*
Kaiko, R. F., Benziger, D. P., Fitzmartin, R. D., Burke, B. E., Reder, R. F., & Goldenheim, P. D. (1996) · Clinical Pharmacology & Therapeutics · doi:10.1016/s0009-9236(96)90024-7 · Cited by 180
Self-citationMaddocks, I., Somogyi, A., Abbott, F., Hayball, P., & Parker, D. (1996) · Journal of Pain and Symptom Management · doi:10.1016/0885-3924(96)00050-4 · Cited by 169 · cited 1×
“Oxycodone has a rapid onset of action (O’Brien, 1996), and its oral bioavailability (Leow et al., 1992; Piiyhia et al., 1992b) is approximately twice that of morphine.”
BackgroundA review of oxycodone's clinical pharmacokinetics and pharmacodynamics
Pöyhiä, R., Vainio, A., & Kalso, E. A. (1993) · Journal of Pain and Symptom Management · doi:10.1016/0885-3924(93)90101-z · Cited by 159
Leow, K. P., Smith, M. T., Williams, B., & Cramond, T. (1992) · Clinical Pharmacology and Therapeutics · doi:10.1038/clpt.1992.176 · Cited by 150
Kalso, E. A., Vainio, A., Mattila, M. J., Rosenberg, P. H., & Seppαlä, T. (1990) · Pharmacology & Toxicology · doi:10.1111/j.1600-0773.1990.tb00838.x · Cited by 98 · cited 2×
“While reports in the literature suggest that the oxycodone metabolite, oxymorphone, has analgesic properties (Kalso et al., 1990; Chen et al., 1991; Otton et al., 1993) its plasma concentration in man is very low.”
BackgroundAge and the Pharmacokinetics of Morphine
BAILLIE, S. P., Bateman, D. N., Coates, P. E., & Woodhouse, K. W. (1989) · Age and Ageing · doi:10.1093/ageing/18.4.258 · Cited by 96 · cited 2×
“Oxycodone may also have advantages over morphine in elderly patients because, unlike morphine pharmacokinetics (Baillie et al., 1989) age has little influence on the pharmacokinetics of oxycodone (Benziger et al., 1996).”
BackgroundDose-ranging study of oxycodone for chronic pain in advanced cancer.
Glare, P. A., & Walsh, D. (1993) · Journal of Clinical Oncology · doi:10.1200/jco.1993.11.5.973 · Cited by 89 · cited 2×
“Oxycodone is an effective analgesic for chronic cancer pain Paper received 12 December 1997, revised 5 June 1998 and (Kalso & Vainio, 1990; Glare & Walsh, 1993; accepted in revised form 3 July 1998.”
BackgroundPharmacokinetics and pharmacodynamics of controlled‐release opioids
Kaiko, R. F. (1997) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1997.tb04633.x · Cited by 55 · cited 3×
“…has analgesic properties (Kalso et al., 1990; Chen et al., 1991; Otton et al., 1993), pharmacokinetic-pharmacodynamic studies suggest that oxycodone rather than oxymorphone is primarily responsible for pharmacological effects in man (Kaiko et al., 1996; Heiskanen et al., 1997; Kaiko, 1997).”
BackgroundSelf-citationSteady-state bioavailability of controlled-release oxycodone in normal subjects
Reder, R. F., Oshlack, B., Miotto, J. B., Benziger, D. D., & Kaiko, R. F. (1996) · Clinical Therapeutics · doi:10.1016/s0149-2918(96)80182-2 · Cited by 52 · cited 3×
“Trough (C&J and approximate peak (C,,) plasma opioid concentrations were determined from blood samples taken at 0 and 3 h (Savarese et al., 1986; Thirlwell et al., 1989; Reder et al., 1996) after the last dose, respectively.”
BackgroundMethodInfluentialSelf-citation
Cited by
The Promotion and Marketing of OxyContin: Commercial Triumph, Public Health Tragedy
Van Zee, A. (2009) · American Journal of Public Health · doi:10.2105/ajph.2007.131714 · Cited by 910
Pergolizzi, J., Böger, R. H., Budd, K., Dahan, A., Erdine, S., Hans, G., Kress, H., Langford, R., Likar, R., Raffa, R. B., et al. (2008) · Pain Practice · doi:10.1111/j.1533-2500.2008.00204.x · Cited by 854
Vondrackova, D., Leyendecker, P., Meissner, W., Hopp, M., Szombati, I., Hermanns, K., Ruckes, C., Weber, S., Grothe, B., Fleischer, W., et al. (2008) · The Journal of Pain · doi:10.1016/j.jpain.2008.06.014 · Cited by 210
Guidelines for supportive care in multiple myeloma 2011
Snowden, J. A., Ahmedzai, S. H., Ashcroft, J., D’Sa, S., Littlewood, T., Low, E., Lucraft, H., Maclean, R., Feyler, S., Pratt, G., et al. (2011) · British Journal of Haematology · doi:10.1111/j.1365-2141.2011.08574.x · Cited by 206
“For rapid onset, the normal release preparation can be used 4–6 hourly or qid, but most patients eventually prefer the convenience of the bd sustained release forms (Mucci-LoRusso et al, 1998).”
BackgroundAdverse drug interactions involving common prescription and over-the-counter analgesic agents
Hersh, E. V., Pinto, A., & Moore, P. A. (2007) · Clinical Therapeutics · doi:10.1016/j.clinthera.2007.12.003 · Cited by 182
Metadata
- Authors
- Mucci‐LoRusso, P., Berman, B. S., Silberstein, P. T., Citron, M. L., Bressler, L., Weinstein, S. M., Kaiko, R. F., Buckley, B. J., & Reder, R. F.
- Venue
- European Journal of Pain
- Publisher
- Wiley
- Published
- 1998-09
- Volume
- 2
- Issue
- 3
- Pages
- 239-249
- ISSN
- 1090-3801 (ISSN-L)
- 1532-2149
- OpenAlex
- W2071858540
- Cited by
- 175
- References
- 25
- FWCI
- 3.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.