Automatic recognition of alertness and drowsiness from EEG by an artificial neural network
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
We present a novel method for classifying alert vs drowsy states from 1 s long sequences of full spectrum EEG recordings in an arbitrary subject. This novel method uses time series of interhemispheric and intrahemispheric cross spectral densities of full spectrum EEG as the input to an artificial neural network (ANN) with two discrete outputs: drowsy and alert. The experimental data were collected from 17 subjects. Two experts in EEG interpretation visually inspected the data and provided the necessary expertise for the training of an ANN. We selected the following three ANNs as potential candidates: (1) the linear network with Widrow-Hoff (WH) algorithm; (2) the non-linear ANN with the Levenberg-Marquardt (LM) rule; and (3) the Learning Vector Quantization (LVQ) neural network. We showed that the LVQ neural network gives the best classification compared with the linear network that uses WH algorithm (the worst), and the non-linear network trained with the LM rule. Classification properties of LVQ were validated using the data recorded in 12 healthy volunteer subjects, yet whose EEG recordings have not been used for the training of the ANN. The statistics were used as a measure of potential applicability of the LVQ: the t-distribution showed that matching between the human assessment and the network output was 94.37+/-1.95%. This result suggests that the automatic recognition algorithm is applicable for distinguishing between alert and drowsy state in recordings that have not been used for the training.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in neural information processing systems 7
Cios, K., & Shields, M. (1997) · Neurocomputing · doi:10.1016/s0925-2312(97)90018-7 · Cited by 22,059
Multilayer feedforward networks are universal approximators
Hornik, K., Stinchcombe, M., & White, H. (1989) · Neural Networks · doi:10.1016/0893-6080(89)90020-8 · Cited by 21,728
Neural computing: theory and practice
(1989) · Choice Reviews Online · doi:10.5860/choice.27-1569 · Cited by 1,663 · cited 2×
“Based on the extensive literature [8,22,24,25,28] three ANNs were selected for this study: a Learning Vector Quantization (LVQ) [33], a feed-forward network that uses the Levenberg–Marquardt learning (LM) rule [34], and a linear network that uses Widrow–Hoff rules [34].”
MethodStatistical methods in medical research
Menduke, H. (1972) · Journal of the Franklin Institute · doi:10.1016/0016-0032(72)90050-6 · Cited by 1,263
Neural computing: Theory and practice
O'Toole, A. J. (1990) · Neural Networks · doi:10.1016/0893-6080(90)90059-t · Cited by 1,044
Neocortical Dynamics and Human EEG Rhythms
Nunez, P. L., & Williamson, S. J. (1996) · Physics Today · doi:10.1063/1.2807585 · Cited by 1,001 · cited 1×
“EEG signals, are dynamic, stochastic, non-linear and non-stationary [1–4].”
Neural networks and their applications
Bishop, C. M. (1994) · Review of Scientific Instruments · doi:10.1063/1.1144830 · Cited by 926
Mackay, D. J. C. (1995) · Network Computation in Neural Systems · doi:10.1088/0954-898x/6/3/011 · Cited by 915
Neocortical Dynamics and Human EEG Rhythms
Collura, T. F. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199603000-00010 · Cited by 892
Estimating alertness from the EEG power spectrum
Jung, T.-P., Makeig, S., Stensmo, M., & Sejnowski, T. J. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.553713 · Cited by 480 · cited 6×
“A computer-assisted EEG classification of drowsiness has been analysed in several studies [6–15].”
BackgroundMethodInfluential
Cited by
Borghini, G., Astolfi, L., Vecchiato, G., Mattia, D., & Babiloni, F. (2014) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2012.10.003 · Cited by 1,331
Using EEG spectral components to assess algorithms for detecting fatigue
Jap, B. T., Lal, S., Fischer, P., & Bekiaris, E. (2009) · Expert Systems with Applications · doi:10.1016/j.eswa.2007.12.043 · Cited by 729
Driver Fatigue Detection Systems: A Review
Sikander, G., & Anwar, S. (2019) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2018.2868499 · Cited by 556
EEG-based drowsiness estimation for safety driving using independent component analysis
Lin, C.-T., Wu, R.-C., Liang, S.-F., Chao, W.-H., Chen, Y.-J., & Jung, T.-P. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.857555 · Cited by 470
Can SVM be used for automatic EEG detection of drowsiness during car driving?
Yeo, M. V. M., Li, X., Shen, K., & Wilder-Smith, E. P. V. (2009) · Safety Science · doi:10.1016/j.ssci.2008.01.007 · Cited by 368
Automatic recognition of alertness level from EEG by using neural network and wavelet coefficients
SUBASI, A. (2005) · Expert Systems with Applications · doi:10.1016/j.eswa.2004.12.027 · Cited by 289
Hramov, A. E., Maksimenko, V. A., & Pisarchik, A. N. (2021) · Physics Reports · doi:10.1016/j.physrep.2021.03.002 · Cited by 213
Drowsy driver detection system using eye blink patterns
Danisman, T., Bilasco, I. M., Djeraba, C., & Ihaddadene, N. (2010) · 2010 International Conference on Machine and Web Intelligence · doi:10.1109/icmwi.2010.5648121 · Cited by 211
“It includes eye-lid closure, electrooculogram (EOG) [7] and electroencephalogram (EEG) [4], [5], [6].”
Classification of EEG signals using relative wavelet energy and artificial neural networks
Guo, L., Rivero, D., Seoane, J. A., & Pazos, A. (2009) · Proceedings of the first ACM/SIGEVO Summit on Genetic and Evolutionary Computation · doi:10.1145/1543834.1543860 · Cited by 192
“Recently, ANNs that apply Bayesian methods are shown to be more robust compared with other techniques because they incorporate measures of confidence in their output for the Levenberg-Marquardt (LM) procedure [21].”
MethodEpileptic seizure detection using dynamic wavelet network
SUBASI, A. (2005) · Expert Systems with Applications · doi:10.1016/j.eswa.2005.04.007 · Cited by 189
A Systemic Review of Available Low-Cost EEG Headsets Used for Drowsiness Detection
LaRocco, J., Le, M. D., & Paeng, D.-G. (2020) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2020.553352 · Cited by 187
Chen, L.-L., Zhao, Y., Zhang, J., & Zou, J.-Z. (2015) · Expert Systems with Applications · doi:10.1016/j.eswa.2015.05.028 · Cited by 179
“Artificial neural network (ANN) (Garcés Correa et al., 2014; Singh et al., 2013; Subasi, 2005; Vuckovic et al., 2002) and support vector machine (SVM) (Hu & Zheng, 2009; Jo et al.”
BackgroundInfluentialShen, K.-Q., Li, X.-P., Ong, C.-J., Shao, S.-Y., & Wilder-Smith, E. P. V. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.03.012 · Cited by 176
“…several studies have reported the feasibility of detecting operator drowsiness based on EEG data in attention-sustained experiments (Jung et al., 1997; Makeig et al., 2000; Sommer et al., 2002; Vuckovic et al., 2002; Lal et al., 2003; Duta et al., 2004; Peiris et al., 2004; Jones, 2006).”
BackgroundInfluentialWavelet neural network classification of EEG signals by using AR model with MLE preprocessing
Subasi, A., Alkan, A., Koklukaya, E., & Kiymik, M. K. (2005) · Neural Networks · doi:10.1016/j.neunet.2005.01.006 · Cited by 167
Cross-session classification of mental workload levels using EEG and an adaptive deep learning model
Yin, Z., & Zhang, J. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.11.013 · Cited by 163
Noninvasive Neural Prostheses Using Mobile and Wireless EEG
Lin, C.-T., Ko, L.-W., Chiou, J.-C., Duann, J.-R., Huang, R.-S., Liang, S.-F., Chiu, T.-W., & Jung, T.-P. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922561 · Cited by 160
Utilization of a combined EEG/NIRS system to predict driver drowsiness
Nguyen, T., Ahn, S., Jang, H., Jun, S. C., & Kim, J. G. (2017) · Scientific Reports · doi:10.1038/srep43933 · Cited by 158
EEG-Based Lapse Detection With High Temporal Resolution
Davidson, P. R., Jones, R. D., & Peiris, M. T. R. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893452 · Cited by 158
“, [3], [12], [20], and [21]), our system makes use of the temporal dynamics of”
BackgroundPromises and Challenges in the Use of Consumer-Grade Devices for Sleep Monitoring
Roomkham, S., Lovell, D., Cheung, J., & Perrin, D. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2811735 · Cited by 79
Metadata
- Authors
- Vuckovic, A., Radivojevic, V., Chen, A. C. N., & Popovic, D.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2002-05-06
- Volume
- 24
- Issue
- 5
- Pages
- 349-360
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W1999269011
- Cited by
- 198
- References
- 26
- FWCI
- 2.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.