Inflation of a pressure-limited cuff inside a model trachea
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A theory of the elastic behaviour of thin rubber films is developed to describe inflation of pressure-limited tracheal tube cuffs (a) outside and (b) inside rigid cylindrical model tracheas. At each stage, assumptions and results were successfully checked against experiment. The theory predicts cylinder wall versus intracuff pressure. This allows, for any suitable cuff (of which there are many), the determination of a single intracuff pressure that ensures a satisfactory seal, for any diameter within the human adult range, the wall pressure staying below some chosen safety limit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gases, Liquids and Solids: And Other States of Matter
Tabor, D. (1991) · doi:10.1017/cbo9781139170253 · Cited by 127
Cited by
A low-volume, low-pressure tracheal tube cuff reduces pulmonary aspiration*
Young, P. J., Pakeerathan, S., Blunt, M. C., & Subramanya, S. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000201406.57821.5b · Cited by 296
Self-citation
Metadata
- Authors
- Young, P. J., & Young, W. H.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2003-05-27
- Volume
- 25
- Issue
- 6
- Pages
- 465-473
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W1974365876
- Cited by
- 168
- References
- 1
- FWCI
- 0.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inflation of a pressure-limited cuff inside a model trachea. https://app.cochat.ai/papers/10.1016/s1350-4533(02)00252-7
- The paper
- Young, P. J., & Young, W. H. (2003). Inflation of a pressure-limited cuff inside a model trachea. Medical Engineering & Physics. https://doi.org/10.1016/s1350-4533(02)00252-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.