CoChat

Inflation of a pressure-limited cuff inside a model trachea

Young, P.J., Young, W.H. · 2003 · Medical Engineering & Physics
Cited by 168

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A theory of the elastic behaviour of thin rubber films is developed to describe inflation of pressure-limited tracheal tube cuffs (a) outside and (b) inside rigid cylindrical model tracheas. At each stage, assumptions and results were successfully checked against experiment. The theory predicts cylinder wall versus intracuff pressure. This allows, for any suitable cuff (of which there are many), the determination of a single intracuff pressure that ensures a satisfactory seal, for any diameter within the human adult range, the wall pressure staying below some chosen safety limit.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s1350-4533(02)00252-7

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 168

Metadata

Authors
Young, P. J., & Young, W. H.
Venue
Medical Engineering & Physics
Published
2003-05-27
Volume
25
Issue
6
Pages
465-473
ISSN
  • 1350-4533 (ISSN-L)
  • 1873-4030
OpenAlex
W1974365876
Cited by
168
References
1
FWCI
0.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inflation of a pressure-limited cuff inside a model trachea. https://app.cochat.ai/papers/10.1016/s1350-4533(02)00252-7
The paper
Young, P. J., & Young, W. H. (2003). Inflation of a pressure-limited cuff inside a model trachea. Medical Engineering & Physics. https://doi.org/10.1016/s1350-4533(02)00252-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.