Three-dimensional dynamic behaviour of the human knee joint under impact loading
The DOI matches its Crossref record.
Abstract
The objective of this study is to determine the three-dimensional dynamic response of the human knee joint. A three-dimensional anatomical dynamic model was thus developed and consists of two body segments in contact (the femur and tibia) executing a general three-dimensional dynamic motion within the constraints of the different ligamentous structures. Each of the articular surfaces at the tibio-femoral joint was represented mathematically by a separate mathematical function. The joint ligaments were modelled as nonlinear elastic springs. The six-degrees-of-freedom joint motions were characterized by using six kinematic parameters, and ligamentous forces were expressed in terms of these six parameters. Knee response was studied by considering sudden external forcing pulse loads applied to the tibia. Model equations consist of nonlinear second-order ordinary differential equations coupled with nonlinear algebraic constraint conditions. Constraint equations were written to maintain at least one-point contact throughout motion; one- and two-point contact versions of the model were developed. This Differential-Algebraic Equations (DAE) system was solved by employing a DAE solver: the Differential/Algebraic System Solver (DASSL) developed at Lawrence Livermore National Laboratory. A solution representing the response of this three-dimensional dynamic system was thus obtained for the first time. Earlier attempts to determine the system's response were unsuccessful owing to the inherent numerical instabilities in the system and the limitations of the solution techniques. Under the conditions tested, evidence of "femoral roll back" on both medial and lateral tibial plateaus was not observed from the model predictions. In the range of 20 degrees to 66 degrees of knee flexion, the lateral tibial contact point moved posteriorly while the medial tibial contact point moved anteriorly. In the range of 66 degrees to 90 degrees of knee flexion, contact was maintained only on the medial side and the tibial contact point (on the medial side) continued to move anteriorly. It was further found that increasing pulse amplitude and/or duration caused a decrease in the magnitude of the tibio-femoral contact force at a given flexion angle. These results suggest that increasing load level caused a decrease in joint stiffness. The results of this study also show that the anterior fibres of the posterior cruciate and the medial collateral ligaments are the primary restraints for a posterior forcing pulse in the range of 20 degrees to 90 degrees of knee flexion; this explains why most isolated posterior cruciate ligament injuries and combined injuries to the posterior cruciate and the medial collateral result from a posterior impact on a flexed knee.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A three-dimensional osteochondral composite scaffold for articular cartilage repair
Sherwood, J. K., Riley, S. L., Palazzolo, R., Brown, S. C., Monkhouse, D. C., Coates, M., Griffith, L. G., Landeen, L. K., & Ratcliffe, A. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00223-5 · Cited by 610
Computational Modeling of Ligament Mechanics
Weiss, J. A., & Gardiner, J. C. (2001) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v29.i3.20 · Cited by 244
SHIN, C. S., CHAUDHARI, A. M., & ANDRIACCHI, T. P. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820f8395 · Cited by 241
Model Prediction of Anterior Cruciate Ligament Force during Drop-Landings
PFLUM, M. A., SHELBURNE, K. B., TORRY, M. R., DECKER, M. J., & PANDY, M. G. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000145467.79916.46 · Cited by 216
The effect of isolated valgus moments on ACL strain during single-leg landing: A simulation study
Shin, C. S., Chaudhari, A. M., & Andriacchi, T. P. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.10.031 · Cited by 204
“…(PCL), MCL, LCL, posterior capsules, and patellar ligament) formulated as non-linear elastic springs (Shin et al., 2007) with properties adapted from published data (Abdel-Rahman and Hefzy, 1998; Cooper et al., 1993; Noyes et al., 1984; Shelburne and Pandy, 1997; Woo et al., 1991; Yu et al., 2001).”
MethodThe influence of deceleration forces on ACL strain during single-leg landing: A simulation study
Shin, C. S., Chaudhari, A. M., & Andriacchi, T. P. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.05.004 · Cited by 193
“The ACL and the posterior cruciate ligament (PCL) were modeled using two bundles, as done in previous simulation models (Yu et al., 2001; Blankevoort et al., 1991; Abdel-Rahman and Hefzy, 1998), since two functional bundles have been identified in clinical and cadaver studies (Girgis et al.”
BackgroundMethodResultInfluentialThe mechanical consequences of dynamic frontal plane limb alignment for non-contact ACL injury
Chaudhari, A. M., & Andriacchi, T. P. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.11.013 · Cited by 163
Three-Dimensional Dynamic Simulation of Total Knee Replacement Motion During a Step-Up Task
Piazza, S. J., & Delp, S. L. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1406950 · Cited by 158
Zhang, Y., Hunter, D. J., Nevitt, M. C., Xu, L., Niu, J., Lui, L., Yu, W., Aliabadi, P., & Felson, D. T. (2004) · Arthritis & Rheumatism · doi:10.1002/art.20127 · Cited by 153
Tibiofemoral joint contact forces and knee kinematics during squatting
Smith, S. M., Cockburn, R. A., Hemmerich, A., Li, R. M., & Wyss, U. P. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.05.004 · Cited by 72
An in vivo subject-specific 3D functional knee joint model using combined MR imaging
Chen, B., Lambrou, T., Offiah, A. C., Gondim Teixeira, P. A., Fry, M., & Todd-Pokropek, A. (2013) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-012-0801-7 · Cited by 7
Metadata
- Authors
- Abdel-Rahman, E. M., & Hefzy, M. S.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 1998-06-01
- Volume
- 20
- Issue
- 4
- Pages
- 276-290
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W1977228744
- Cited by
- 144
- References
- 0
- FWCI
- 1.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.