Source strength of fungal spore aerosolization from moldy building material
The DOI matches its Crossref record; 25 of the 29 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In our recent investigation on the release of fungal spores, performed in the laboratory under controlled environmental conditions (18), we found that parameters such as fungal species, air velocity above the surface, texture of the surface, and vibration of contaminated material affected the release of spores.”
From Fungal Fragments as Indoor Air Biocontaminants (2002) · cites this paper as [18]
In the citing paper
“Our recent findings (18) reveal that the spore release from agar increased with increasing air velocity.”
From Fungal Fragments as Indoor Air Biocontaminants (2002) · cites this paper as [18]
In the citing paper
“The same observation was previously concluded for the spore release experiments (18).”
From Fungal Fragments as Indoor Air Biocontaminants (2002) · cites this paper as [18]
In the citing paper
“Similar to results obtained for spores (18), the vibration was shown to increase the release of fungal fragments at the low air velocity.”
From Fungal Fragments as Indoor Air Biocontaminants (2002) · cites this paper as [18]
In the citing paper
“This is almost the same percentage as that determined earlier for intact spore release (18).”
From Fungal Fragments as Indoor Air Biocontaminants (2002) · cites this paper as [18]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Humidity fixed points of binary saturated aqueous solutions
Greenspan, L. (1977) · Journal of Research of the National Bureau of Standards Section A: Physics and Chemistry · doi:10.6028/jres.081a.011 · Cited by 4,001
The Microbiology of the Atmosphere
Kramer, C. L., & Gregory, P. H. (1974) · Mycologia · doi:10.2307/3758380 · Cited by 976
Bioaerosols and occupational lung disease
Lacey, J., & Dutkiewicz, J. (1994) · Journal of Aerosol Science · doi:10.1016/0021-8502(94)90215-1 · Cited by 342
Correlation between the prevalence of certain fungi and sick building syndrome.
Cooley, J. D., Wong, W. C., Jumper, C. A., & Straus, D. C. (1998) · Occupational and Environmental Medicine · doi:10.1136/oem.55.9.579 · Cited by 329
Fungi as a Cause of Allergic Disease
Gravesen, S. (1979) · Allergy · doi:10.1111/j.1398-9995.1979.tb01562.x · Cited by 328
Health effects of indoor-air microorganisms
Husman, T. (1996) · Scandinavian Journal of Work, Environment & Health · doi:10.5271/sjweh.103 · Cited by 289
Fungi as contaminants in indoor air
Miller, J. D. (1992) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(92)90404-9 · Cited by 236
Burnett, J. H. (1976) · Edward Arnold eBooks · Cited by 199
Significance of air humidity and air velocity for fungal spore release into the air
Pasanen, A.-L., Pasanen, P., Jantunen, M. J., & Kalliokoski, P. (1991) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(91)90316-y · Cited by 191
Effect of relative humidity on the aerodynamic diameter and respiratory deposition of fungal spores
Reponen, T., Willeke, K., Ulevicius, V., Reponen, A., & Grinshpun, S. A. (1996) · Atmospheric Environment · doi:10.1016/1352-2310(96)00128-8 · Cited by 170
Self-citation
Research works printed but not linked: 6
- Baran, E. (Ed.), 1998. Medical Mycology—an Overview. Volumed, Wrocław, pp. 289–531.
- Burge, H.A., Otten, J.A., 1999. Fungi. In: Macher, J. (Ed.), Bioaerosols: Assessment and Control. American Conference of Governmental Industrial Hygienists, Cincinnati, pp. 19.1–19.13.
- Foarde, K., Dulaney, P., Cole, E., VanOsdel, D., Ensor, D., Chang, J., 1993. Assessment of fungal growth on ceiling tiles under environmentally characterized conditions. In: Kalliokoski, P., Jantunen, M., Seppänen, O. (Eds.), Proceedings of Indoor Air 93, Vol. 4, pp. 357–362.
- Haines, J., Escamilla, B., Muilenberg, M., Gallup, J., Levetin, E., 1999. Mycology of the Air. Pan American Aerobiology Association, pp. 1–5.
- Key, D., 1988. The calculation of structure response. In: Earthquake Design Practice for Buildings. Thomas Telford, London, pp. 41–68.
- Spengler, J.D., Neas, L., Nakai, S., Dockery, D., Speizer, F., Ware, J., Raizenne, M., 1993. Respiratory symptoms and house characteristics. In: Kalliokoski, P., Jantunen, M., Seppänen, O. (Eds.), Proceedings of Indoor Air 93, vol. 1, pp. 165–171.
Cited by
Items 101–116 of 116
Minahan, N. T., Chen, C., Hsu, C.-C., Chuang, Y.-C., Ma, X.-T., & Guo, Y. L. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.114944 · Cited by 1
Extrinsic allergic alveolitis from the bedroom
Marin, A., Mušič, E., Eržen, R., Uršič, V., & Korošec, P. (2009) · Allergo Journal · doi:10.1007/bf03362132 · Cited by 1
Universitatea Naţională de Arte, B., Gomoiu, I., Mohanu, D., Universitatea Naţională de Arte, B., Mohanu, I., & CEPROCIM, B. (2010) · CaieteARA Arhitectură Restaurare Arheologie · doi:10.47950/caieteara.2010.1.05 · Cited by 1
Evaluation of a Fungal Spore Transportation in a Building under Uncertainty
Moon, H. J. (2006) · Architectural research · doi:10.1007/bf03656149 · Cited by 1
Microbial growth on plasterboard and spore-induced cytotoxicity and inflammatory responses in vitro
Murtoniemi, T. (2003) · STM:n Hallinnonalan avoin julkaisuarkisto (Julkari) · Cited by 3
Monroy, A. M. T. (2020) · theses.fr (ABES) · doi:10.70675/cc428785z389bz47f9zbe76zdd2307a12600 · Cited by 10
Aleksic, B. (2016) · theses.fr (ABES) · doi:10.70675/9ce079baz94fbz435cz9353z7f66c43894f9 · Cited by 1
Zastosowanie promieniowania mikrofalowego w kontroli skażenia mikrobiologicznego środowiska wnętrz
Górny, R. L. (2011) · Ekologia i Technika
Self-citationMicrobial Bioaerosols in the Occupational Environment: Exposure, Detection, and Disease
Reponen, T. A., & Green, B. J. (2012) · Wiley eBooks · doi:10.1002/0471435139.tox019.pub2 · Cited by 1
Self-citationSTUDIES ON SEASONAL VARIATION OF INDOOR AIRBORNE FUNGAL SPORES IN RABBIT HOUSE
Pavan, R., Ponnamma, S. U., & Manjunath, K. (2014) · ePrints@Bangalore University (Bangalore University)
The effect of fire scars on microbial diversity of fynbos soil
Smart, R. V. (2017) · SUNScholar (Stellenbosch University)
Micu, R. M. (2025) · ROMANIAN BIOTECHNOLOGICAL LETTERS · doi:10.25083/rbl/28.6/4169.4176
Distribution of mycotoxins in fungal structures
Errede, D. C. (2011) · University of Minnesota Digital Conservancy (University of Minnesota)
Forthomme, A. (2012) · theses.fr (ABES) · doi:10.70675/d0ac8336z1cbcz40b5zac39z6892f7543b85 · Cited by 4
Caractérisation de la diversité microbienne de l’air des espaces clos.
Gaüzère, C. (2012) · theses.fr (ABES) · doi:10.70675/25ce1375z5f11z4051zbe76zf10bca4695fe · Cited by 2
Metadata
- Authors
- Górny, R. L., Reponen, T., Grinshpun, S. A., & Willeke, K.
- Affiliations
- University of Cincinnati (US)
- Corresponding author
- Górny, Rafał L.
- Venue
- Atmospheric Environment
- Publisher
- Elsevier BV
- Published
- 2001-10
- Volume
- 35
- Issue
- 28
- Pages
- 4853-4862
- ISSN
- 1352-2310 (ISSN-L)
- OpenAlex
- W2000788967
- Semantic Scholar
- 189e59f0c540f882e2e3455337360a901a76f249
- Cited by
- 114
- References
- 29
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 2 · 2023: 2 · 2022: 5 · 2021: 4 · 2020: 3 · 2019: 3 · 2018: 2 · 2017: 7 · 2016: 6 · 2015: 4 · 2014: 5 · 2013: 3 · 2012: 6
- FWCI
- 3.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Atmospheric Environment (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Life Sciences › Agricultural and Biological Sciences › Plant Science › Mycotoxins in Agriculture and Food
- Keywords
- Aspergillus versicolor, Cladosporium cladosporioides, Penicillium melinii, ceiling tiles, mechanical vibration, surface texture, conidiophore morphology, indoor air quality
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.