The DOI matches its Crossref record; 17 of the 18 references it cites were found in a registry or an index.
Effects of room furnishings and air speed on particle deposition rates indoors
Open accessOverview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“There seems little doubt, when taking into account macro air movements related to heating and ventilation, convection, people activity, and even more localised radiative warming due to equipment, the human body and sunshine through windows, a large fraction of respiratory generated particles will be entrained and suspended in air currents and may potentially travel significant distances over time”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [34]
Citations
Cites
An association between air pollution and mortality in six U.S. cities
Dockery, D. W., Pope, C. A., Xu, X., Spengler, J. D., Ware, J. H., Fay, M. E., Ferris, B. G., & Speizer, F. E. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312093292401 · Cited by 8,018
Deposition, resuspension, and penetration of particles within a residence
Thatcher, T. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00016-r · Cited by 859
Self-citationMODELING INDOOR PARTICLE DEPOSITION FROM TURBULENT FLOW ONTO SMOOTH SURFACES
K. Lai, A. C., & Nazaroff, W. W. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00536-4 · Cited by 696
Self-citationHealth effects of particulate air pollution: time for reassessment?
Pope, C. A., Bates, D. V., & Raizenne, M. E. (1995) · Environmental Health Perspectives · doi:10.1289/ehp.95103472 · Cited by 528
Long, C. M., Suh, H. H., Catalano, P. J., & Koutrakis, P. (2001) · Environmental Science & Technology · doi:10.1021/es001477d · Cited by 443
Indoor particulate matter of outdoor origin: Importance of size-dependent removal mechanisms
Riley, W. J., McKone, T. E., Lai, A. C. K., & Nazaroff, W. W. (2002) · Environmental Science & Technology · doi:10.1021/es010723y · Cited by 417
Self-citationActivity patterns of Californians: Use of and proximity to indoor pollutant sources
Jenkins, P. L., Phillips, T. J., Mulberg, E. J., & Hui, S. P. (1992) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(92)90402-7 · Cited by 415
Relative contribution of outdoor and indoor particle sources to indoor concentrations
Abt, E., Suh, H. H., Catalano, P., & Koutrakis, P. (2000) · Environmental Science & Technology · doi:10.1021/es990348y · Cited by 411
Vette, A. F., Rea, A. W., Lawless, P. A., Rodes, C. E., Evans, G., Highsmith, V. R., & Sheldon, L. (2001) · Aerosol Science and Technology · doi:10.1080/02786820117903 · Cited by 186
Penetration of Ambient Fine Particles into the Indoor Environment
Mosley, R. B., Greenwell, D. J., Sparks, L. E., Guo, Z., Tucker, W. G., Fortmann, R., & Whitfield, C. (2001) · Aerosol Science and Technology · doi:10.1080/02786820117449 · Cited by 174
Research works printed but not linked: 1
- Thorshauge, 1982, Air velocity fluctuations in the occupied zone of ventilated spaces, ASHRAE Transactions, 88, 753
Cited by
Chen, C., & Zhao, B. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.09.048 · Cited by 972
Miller, S. L., Nazaroff, W. W., Jimenez, J. L., Boerstra, A., Buonanno, G., Dancer, S. J., Kurnitski, J., Marr, L. C., Morawska, L., & Noakes, C. (2021) · Indoor Air · doi:10.1111/ina.12751 · Cited by 734
“7 The surface deposition loss rate range was based on data from Thatcher et al. 33 and Diapouli et al. 32 The range of values for virus decay is based on two sources: Fears et al. 1 showed no decay in virus-containing aerosol for 16 hours at 53% RH, whereas van Doremalen et al. 2 estimated the half-life of airborne SA…”
InfluentialSelf-citationNazaroff, W. W. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00286.x · Cited by 639
“Among the factors that can increase particle deposition are more intense airflow and increased indoor surface area (Thatcher et al., 2002).”
BackgroundSelf-citationZhao, B., Zhang, Y., Li, X., Yang, X., & Huang, D. (2003) · Building and Environment · doi:10.1016/j.buildenv.2003.08.002 · Cited by 447
Size‐resolved emission rates of airborne bacteria and fungi in an occupied classroom
Qian, J., Hospodsky, D., Yamamoto, N., Nazaroff, W. W., & Peccia, J. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00769.x · Cited by 395
“Averaged across all size ranges, the indoor air occupied-to-vacant ratios of particulate matter mass concentrations, bacterial genome concentrations, and equivalent fungal genome concentrations were 15, 170, and 2.3, respectively.”
BackgroundMethodInfluentialSelf-citation
Metadata
- Authors
- Thatcher, T. L., Lai, A. C. K., Moreno-Jackson, R., Sextro, R. G., & Nazaroff, W. W.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Thatcher, Tracy L.
- Venue
- Atmospheric Environment
- Publisher
- Elsevier BV
- Published
- 2002-04
- Volume
- 36
- Issue
- 11
- Pages
- 1811-1819
- ISSN
- 1352-2310 (ISSN-L)
- OpenAlex
- W1540159194
- Cited by
- 416
- References
- 18
- Citations by year
- 2026: 18 · 2025: 16 · 2024: 17 · 2023: 25 · 2022: 31 · 2021: 47 · 2020: 20 · 2019: 16 · 2018: 15 · 2017: 9 · 2016: 15 · 2015: 23 · 2014: 16 · 2013: 17 · 2012: 15
- FWCI
- 9.73
- Type
- journal article
- Language
- en
- Open access
- green
- www.osti.gov
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Atmospheric Environment (publishedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- University of North Texas Digital Library (University of North Texas) (submittedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Lawrence Berkeley National Laboratory
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- particle deposition, indoor air quality, room furnishing, carpets, air velocity, particle size effects, PM2.5, PM10
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of room furnishings and air speed on particle deposition rates indoors. https://app.cochat.ai/papers/10.1016/s1352-2310(02)00157-7
- The paper
- Thatcher, T. L., Lai, A. C. K., Moreno-Jackson, R., Sextro, R. G., & Nazaroff, W. W. (2002). Effects of room furnishings and air speed on particle deposition rates indoors. Atmospheric Environment. https://doi.org/10.1016/s1352-2310(02)00157-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.