An improved mass transfer based model for analyzing VOC emissions from building materials
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Concentrations and Sources of VOCs in Urban Domestic and Public Microenvironments
Kim, Y. M., Harrad, S., & Harrison, R. M. (2001) · Environmental Science & Technology · doi:10.1021/es000192y · Cited by 394 · cited 1×
“In many new buildings, the emissions of volatile organic compounds (VOCs) from building materials, furniture and equipment may impact indoor air quality, which tends to cause general symptoms, such as headache; eye, nose, or throat irritations; dry cough; dizziness and nausea; difficulty in concentrating; tiredness (K…”
BackgroundThe Interaction of Vapour Phase Organic Compounds with Indoor Sinks
Tichenor, B. A., Guo, Z., Dunn, J. E., Sparks, L. E., & Mason, M. A. (1991) · Indoor Air · doi:10.1111/j.1600-0668.1991.03-11.x · Cited by 191
Measuring partition and diffusion coefficients for volatile organic compounds in vinyl flooring
Cox, S. S., Zhao, D., & Little, J. C. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00175-3 · Cited by 183
The sick buildings and other buildings with indoor climate problems
Mølhave, L. (1989) · Environment International · doi:10.1016/0160-4120(89)90011-1 · Cited by 105
Sparks, L. E., Tichenor, B. A., Chang, J., & Guo, Z. (1996) · Indoor Air · doi:10.1111/j.1600-0668.1996.t01-3-00004.x · Cited by 90
Interaction of volatile organic compounds with indoor materials—a small-scale screening method
Meininghaus, R., Salthammer, T., & KNÖPPEL, H. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(98)00367-7 · Cited by 76
Study of building material emissions and indoor air quality
Yang, X. (1999) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 70
Modeling the reversible, diffusive sink effect in response to transient contaminant sources
Zhao, D., Little, J. C., & Hodgson, A. T. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01116.x · Cited by 43
Silberstein, S., Grot, R. A., Ishiguro, K., & Mulligan, J. L. (1988) · JAPCA · doi:10.1080/08940630.1988.10466480 · Cited by 27
Cited by
Tham, K. W. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.08.071 · Cited by 399
Liu, Z., Ye, W., & Little, J. C. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.02.012 · Cited by 218
“Xu and Zhang [39] developed a semi-analytical (not fully explicit) solution for this equation set, which still requires finite difference method and computation from the initial condition.”
BackgroundMethodInfluentialInfluence of temperature on formaldehyde emission parameters of dry building materials
Zhang, Y., Luo, X., Wang, X., Qian, K., & Zhao, R. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.10.081 · Cited by 194
Self-citationFormaldehyde and VOC emissions at different manufacturing stages of wood-based panels
He, Z., Zhang, Y., & Wei, W. (2012) · Building and Environment · doi:10.1016/j.buildenv.2011.07.023 · Cited by 174
Self-citationWang, H., Guo, D., Zhang, W., Zhang, R., Gao, Y., Zhang, X., Liu, W., Wu, W., Sun, L., Yu, X., et al. (2023) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2023.101375 · Cited by 38
Metadata
- Authors
- Xu, Y., & Zhang, Y.
- Venue
- Atmospheric Environment
- Publisher
- Elsevier BV
- Published
- 2003-06
- Volume
- 37
- Issue
- 18
- Pages
- 2497-2505
- ISSN
- 1352-2310 (ISSN-L)
- OpenAlex
- W2036620811
- Cited by
- 217
- References
- 9
- FWCI
- 3.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.