Anion recognition: synthetic receptors for anions and their application in sensors
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
Artificial Organic Host Molecules for Anions
Schmidtchen, F. P., & Berger, M. (1997) · Chemical Reviews · doi:10.1021/cr9603845 · Cited by 1,788
Structure of the influenza virus haemagglutinin complexed with its receptor, sialic acid
Weis, W., Brown, J. H., Cusack, S., Paulson, J. C., Skehel, J. J., & Wiley, D. C. (1988) · Nature · doi:10.1038/333426a0 · Cited by 1,158
Chemical Communication in Water Using Fluorescent Chemosensors
Czarnik, A. W. (1994) · Accounts of Chemical Research · doi:10.1021/ar00046a003 · Cited by 943
Neutral anion receptors: design and application
Antonisse, M. M. G., & Reinhoudt, D. N. (1998) · Chemical Communications · doi:10.1039/a707529d · Cited by 339
A Chemosensor for Citrate in Beverages
Metzger, A., & Anslyn, E. V. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<649::aid-anie649>3.0.co;2-h · Cited by 293
Self-citationChemosensor Ensemble with Selectivity for Inositol-Trisphosphate
Niikura, K., Metzger, A., & Anslyn, E. V. (1998) · Journal of the American Chemical Society · doi:10.1021/ja980990c · Cited by 229
Self-citationStrong hydrogen bond-mediated complexation of H2PO4− by neutral bis-thiourea hosts
Bühlmann, P., Nishizawa, S., Xiao, K. P., & Umezawa, Y. (1997) · Tetrahedron · doi:10.1016/s0040-4020(96)01094-0 · Cited by 229
Dendritic Nucleic Acid Probes for DNA Biosensors
Wang, J., Jiang, M., Nilsen, T. W., & Getts, R. C. (1998) · Journal of the American Chemical Society · doi:10.1021/ja980619p · Cited by 128
Antonisse, M. M. G., Snellink‐Ruël, B. H. M., Yigit, I., Engbersen, J. F. J., & Reinhoudt, D. N. (1997) · The Journal of Organic Chemistry · doi:10.1021/jo9707040 · Cited by 82
Yamamoto, M., Takeuchi, M., & Shinkai, S. (1998) · Tetrahedron · doi:10.1016/s0040-4020(98)00057-x · Cited by 74
Cited by
Fluorogenic and Chromogenic Chemosensors and Reagents for Anions
Martínez-Máñez, R., & Sancenón, F. (2003) · Chemical Reviews · doi:10.1021/cr010421e · Cited by 3,076
Proton-Coupled Electron Transfer
Weinberg, D. R., Gagliardi, C. J., Hull, J. F., Murphy, C. F., Kent, C. A., Westlake, B. C., Paul, A., Ess, D. H., McCafferty, D. G., & Meyer, T. J. (2012) · Chemical Reviews · doi:10.1021/cr200177j · Cited by 2,421
Proton-coupled electron transfer
Huynh, M. H. V., & Meyer, T. J. (2007) · Chemical Reviews · doi:10.1021/cr0500030 · Cited by 1,659
Fluoride Ion Complexation and Sensing Using Organoboron Compounds
Wade, C. R., Broomsgrove, A. E. J., Aldridge, S., & Gabbaï, F. P. (2010) · Chemical Reviews · doi:10.1021/cr900401a · Cited by 1,089
Artificial Receptors for the Recognition of Phosphorylated Molecules
Hargrove, A. E., Nieto, S., Zhang, T., Sessler, J. L., & Anslyn, E. V. (2011) · Chemical Reviews · doi:10.1021/cr100242s · Cited by 649
Self-citation
Metadata
- Authors
- Snowden, T. S., & Anslyn, E. V.
- Venue
- Current Opinion in Chemical Biology
- Publisher
- Elsevier BV
- Published
- 1999-12
- Volume
- 3
- Issue
- 6
- Pages
- 740-746
- ISSN
- 1367-5931 (ISSN-L)
- OpenAlex
- W2031044187
- Cited by
- 291
- References
- 11
- FWCI
- 0.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.