CoChat

Designing optimal spatial filters for single-trial EEG classification in a movement task

The DOI matches its Crossref record; 32 of the 33 references it cites were found in a registry or an index.

Abstract

We devised spatial filters for multi-channel EEG that lead to signals which discriminate optimally between two conditions. We demonstrate the effectiveness of this method by classifying single-trial EEGs, recorded during preparation for movements of the left or right index finger or the right foot. The classification rates for 3 subjects were 94, 90 and 84%, respectively. The filters are estimated from a set of multichannel EEG data by the method of Common Spatial Patterns, and reflect the selective activation of cortical areas. By construction, we obtain an automatic weighting of electrodes according to their importance for the classification task. Computationally, this method is parallel by nature, and demands only the evaluation of scalar products. Therefore, it is well suited for on-line data processing. The recognition rates obtained with this relatively simple method are as good as, or higher than those obtained previously with other methods. The high recognition rates and the method's procedural and computational simplicity make it a particularly promising method for an EEG-based brain-computer interface.

Overview

Integrity signals

Registry

Crossref · 10.1016/s1388-2457(98)00038-8

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 32 references

Research works printed but not linked: 3

  1. Gastaut, 1952, Étude électrocorticographique de la réactivité des rythmes rolandique, Rev Neurol (Paris), 87, 176
  2. Müller-Gerking, 1997, Prompt classification of EEG signals based on their spatial distribution prior to movement, Soc Neurosci Abstr, 23, 1278
  3. Sutter, E.E. Tran, D. Communication through visually induced electrical brain responses. In: Proceedings of the 2nd International Conference: Computers for Handicapped Persons, vol. 55. Schriftenreihe der Österreichischen Computer Gesellschaft, 1990;279-288.

Cited by

See all 925

Metadata

Authors
Müller-Gerking, J., Pfurtscheller, G., & Flyvbjerg, H.
Affiliations
  • Forschungszentrum Jülich (DE)
  • Graz University of Technology (AT)
  • Roskilde University (DK)
Corresponding author
Müller-Gerking, Johannes
Venue
Clinical Neurophysiology
Publisher
Elsevier BV
Published
1999-05
Volume
110
Issue
5
Pages
787-798
ISSN
1388-2457 (ISSN-L)
OpenAlex
W2108824330
Cited by
846
References
33
Citations by year
2026: 18 · 2025: 26 · 2024: 33 · 2023: 43 · 2022: 37 · 2021: 45 · 2020: 45 · 2019: 55 · 2018: 43 · 2017: 38 · 2016: 38 · 2015: 43 · 2014: 52 · 2013: 52 · 2012: 41
FWCI
2.97
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Clinical Neurophysiology (publishedVersion)
  • PubMed (publishedVersion)
  • Research at the University of Copenhagen (University of Copenhagen) (submittedVersion)
  • Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) (submittedVersion)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
Keywords
spatial filtering, single-trial EEG classification, common spatial pattern, motor preparation, motor imagery, brain-computer interface
MeSH terms
Brain, Brain Mapping, Electroencephalography, Humans, Movement, Psychomotor Performance, Reaction Time, Space Perception

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Designing optimal spatial filters for single-trial EEG classification in a movement task. https://app.cochat.ai/papers/10.1016/s1388-2457(98)00038-8
The paper
Müller-Gerking, J., Pfurtscheller, G., & Flyvbjerg, H. (1999). Designing optimal spatial filters for single-trial EEG classification in a movement task. Clinical Neurophysiology. https://doi.org/10.1016/s1388-2457(98)00038-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.